Aldo Iván Saavedra

Dr. Aldo Iván Saavedra


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2021 in Membranes
Verified
Journal Article
Open access
PDF file
ASAldo Iván Saavedra
Aldo Iván Saavedra
HVHugo Valdes
Hugo Valdes
AMAndrea Mahn
Andrea Mahn
OAOrlando Acosta
Orlando Acosta
The aim of this work was to study different desalination technologies as alternatives to conventional reverse osmosis (RO) through a systematic literature review. An expert panel evaluated thermal and membrane processes considering their possible implementation at a pilot plant scale (100 m3/d of purified water) starting from seawater at 20 °C with an average salinity of 34,000 ppm. The desalination plant would be located in the Atacama Region (Chile), where the high solar radiation level justifies an off-grid installation using photovoltaic panels. We classified the collected information about conventional and emerging technologies for seawater desalination, and then an expert panel evaluated these technologies considering five categories: (1) technical characteristics, (2) scale-up potential, (3) temperature effect, (4) electrical supply options, and (5) economic viability. Further, the potential inclusion of graphene oxide and aquaporin-based biomimetic membranes in the desalinization processes was analyzed. The comparative analysis lets us conclude that nanomembranes represent a technically and economically competitive alternative versus RO membranes. Therefore, a profitable desalination process should consider nanomembranes, use of an energy recovery system, and mixed energy supply (non-conventional renewable energy + electrical network). This document presents an up-to-date overview of the impact of emerging technologies on desalinated quality water, process costs, productivity, renewable energy use, and separation efficiency.

3 April 2024 in Chemengineering
Verified
Journal Article
Open access
PDF file
ASAldo Iván Saavedra
Aldo Iván Saavedra
HVHugo Valdes
Hugo Valdes
JVJuan Velásquez
Juan Velásquez
Sebastian HernandezSebastian Hernandez
Sebastian Hernandez
The aim of this study was to analyze, both theoretically and experimentally, the material transport mechanisms governing the separation of ionic species in aqueous solutions using nanofiltration membranes. To interpret the experimental results, the Donnan Steric Partitioning Model (DSPM) and the Dielectric Exclusion Model (DSPM-DE) were applied and computationally simulated in Matlab. Experimental tests were conducted using a pilot-scale system with commercial NF90 membranes. The results indicate that the DSPM better describes the rejection of monovalent ions (sodium and chloride), while the DSPM-DE is more suitable for divalent ions (sulfate and magnesium). Additionally, both models were sensitized to explore the impact of hindrance factors on the rejection of different ionic species. For neutral molecules present in the solution, it was observed that the DSPM and DSPM-DE do not adequately interpret selectivity, suggesting that under such conditions, the electrostatic exclusion mechanism loses significance, with the steric mechanism prevailing.

15 January 2019 in Computation
Verified
Journal Article
Open access
PDF file
HVHugo Valdes
Hugo Valdes
KUKevin Unda
Kevin Unda
ASAldo Iván Saavedra
Aldo Iván Saavedra
This research answers the following question: What is the fluid dynamic behavior of a supercritical fluid (SCF) inside a membrane module? At this time, there is very little or no reported information that can provide an answer to this question. The research studies related to the themes of supercritical CO2 (SC-CO2), hollow fiber membrane contactors (HFMCs), and numerical simulations have mainly reported on 2D simulations, but in this work, 3D profiles are presented. Simulations were performed based on the experimental results and other simulations, using the geometry of a commercial module. The results were mainly based on the different operating conditions and geometric dimensions. A mesh study was performed to ensure the mesh non-dependence of the results presented here. It was observed that the velocity profile developed at 10 mm from the wall of the supercritical CO2 entrance pipe. A profile equilibrium around the fiber close to the entrance of the module was achieved in the experimental hollow fiber membrane contactor when compared to the case of the commercial hollow fiber membrane contactor. The results of this research provided a visualization of the boundary layer, which did not cover the entire fiber length. Finally, the results of this paper are interesting for technical applications and contribute to our understanding of the hydrodynamics of SCFs.

24 September 2025 in Processes
Verified
Journal Article
Open access
PDF file
ASAldo Iván Saavedra
Aldo Iván Saavedra
KFKevin Nicolas Fuentes
Kevin Nicolas Fuentes
HVHugo Valdes
Hugo Valdes
Rosa Isela Ortiz-BasurtoRosa Isela Ortiz-Basurto
Rosa Isela Ortiz-Basurto
Vacuum Membrane Distillation (VMD) is a separation process applied to liquid solutions; however, there are phenomenological and operational differences depending on whether the component to be separated is the solute or the solvent. The objective of this article is to develop a mathematical and phenomenological model of the VMD process applied to the separation of volatile organic compound (VOCs) from aqueous solutions and the desalination of saline aqueous solutions. This approach enabled the evaluation of the influence of variables and operating conditions on both separation efficiency and system productivity. Under the analyzed conditions, increasing the temperature, flow rate, and vacuum pressure led to approximate increases in permeate flux of 400%, 10%, and 50%, respectively. In the case of concentration increase, the permeate flux increases linearly for VOC separation and decreases asymptotically for saline solution desalination. Therefore, adjusting the feed temperature is recommended to achieve significant changes in permeate flux.