Valeria Faccenda

Dr. Valeria Faccenda

Medical physics, Azienda Ospedaliera San Gerardo, Monza, Lombardy, Italy
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2023 in Cancers
Verified
Journal Article
Open access
PDF file
Valeria FaccendaValeria Faccenda
Valeria Faccenda
Denis PanizzaDenis Panizza
Denis Panizza
MDMartina Camilla Daniotti
Martina Camilla Daniotti
RPRoberto Giuseppe Pellegrini
Roberto Giuseppe Pellegrini
STSara Trivellato
Sara Trivellato
SASTEFANO ARCANGELI
STEFANO ARCANGELI
The dosimetric impact of intrafraction prostate motion and interfraction anatomical changes and the effect of beam gating and motion correction were investigated in dose-escalated linac-based SBRT. Fifty-six gated fractions were delivered using a novel electromagnetic tracking device with a 2 mm threshold. Real-time prostate motion data were incorporated into the patient’s original plan with an isocenter shift method. Delivered dose distributions were obtained by recalculating these motion-encoded plans on deformed CTs reflecting the patient’s CBCT daily anatomy. Non-gated treatments were simulated using the prostate motion data assuming that no treatment interruptions have occurred. The mean relative dose differences between delivered and planned treatments were −3.0% [−18.5–2.8] for CTV D99% and −2.6% [−17.8–1.0] for PTV D95%. The median cumulative CTV coverage with 93% of the prescribed dose was satisfactory. Urethra sparing was slightly degraded, with the maximum dose increased by only 1.0% on average, and a mean reduction in the rectum and bladder doses was seen in almost all dose metrics. Intrafraction prostate motion marginally contributed in gated treatments, while in non-gated treatments, further deteriorations in the minimum target coverage and bladder dose metrics would have occurred on average. The implemented motion management strategy and the strict patient preparation regimen, along with other treatment optimization strategies, ensured no significant degradations of dose metrics in delivered treatments.

7 April 2022 in Frontiers in Oncology
Verified
Journal Article
Open access
Denis PanizzaDenis Panizza
Denis Panizza
Valeria FaccendaValeria Faccenda
Valeria Faccenda
RLRaffaella Lucchini
Raffaella Lucchini
MDMartina Camilla Daniotti
Martina Camilla Daniotti
STSara Trivellato
Sara Trivellato
SAStefano Arcangeli
Stefano Arcangeli
Background: Extreme hypofractionation requires tight planning margins, high dose gradients, and strict adherence to planning criteria in terms of patient positioning and organ motion mitigation. This study reports the first clinical experience worldwide using a novel electromagnetic (EM) tracking device for intrafraction prostate motion management during dose-escalated linac-based stereotactic body radiation therapy (SBRT). Methods: Thirteen patients with organ-confined prostate cancer underwent dose-escalated SBRT using flattening filter-free (FFF) volumetric modulated arc therapy (VMAT). The EM tracking device consisted of an integrated Foley catheter with a transmitter. Patients were simulated and treated with a filled bladder and an empty rectum. Setup accuracy was achieved by ConeBeam-CT (CBCT) matching, and motion was tracked during all the procedure. Treatment was interrupted when the signals exceeded a 2 mm threshold in any of the three spatial directions and, unless the offset was transient, target position was re-defined by repeating CBCT. Moreover, the displacements that would have occurred without any intrafraction organ motion management (i.e. no interruptions and repositionings) were simulated. Results: In 31 out of 56 monitored fractions (55%), no intervention was required to correct the target position. In 25 (45%) a correction was mandated, but only in 10 (18%), the beam delivery was interrupted. Total treatment time lasted on average 10.2 minutes, 6.7 minutes for setup, and 3.5 minutes for beam delivery. Without any intrafraction motion management, the overall mean treatment time and the mean delivery time would have been 6.9 minutes and 3.2 minutes, respectively. The prostate would have been found outside the tolerance in 8% of the total session time, in 4% of the time during the setup, and in 14% during the beam-on phase. Predominant motion pattern was posterior and its probability increased with time, with a mean motion ≤ 2 mm occurring within 10 minutes. Conclusions: EM real-time tracking was successfully implemented for intrafraction motion management during dose-escalated prostate SBRT. Results showed that most of the observed displacements were < 2 mm in any direction; however, there were a non-insignificant number of fractions with motion exceeding the predefined threshold, which would have otherwise gone undetected without intrafraction motion management.

10 September 2023 in Cancers
Verified
Journal Article
Open access
PDF file
Valeria FaccendaValeria Faccenda
Valeria Faccenda
Denis PanizzaDenis Panizza
Denis Panizza
VPValerio Pisoni
Valerio Pisoni
STSara Trivellato
Sara Trivellato
MDMartina Camilla Daniotti
Martina Camilla Daniotti
SASTEFANO ARCANGELI
STEFANO ARCANGELI
The efficacy of linac-based SRS/fSRS treatments using the single-isocenter coplanar FFF-VMAT technique for both single and multiple BM was investigated. Seventy patients (129 BM) treated with 15–21 Gy in 1 (n = 59) or 27 Gy in 3 (n = 11) fractions were analyzed. For each fraction, plans involving the intra-fractional errors measured by post-treatment CBCT were recalculated. The relationships of BM size, distance-to-isocenter, and barycenter shift with the difference in target coverage were evaluated. Clinical outcomes were assessed using logistic regression and Kaplan-Meier analysis. The median delivery time was 3.78 min (range, 1.83–9.25). The median post-treatment 3D error was 0.5 mm (range, 0.1–2.7) and the maximum rotational error was 0.3° (range, 0.0–1.3). In single BM patients, the GTV D95% was never reduced by >5%, whereas PTV D95% reductions >1% occurred in only 11 cases (29%). In multiple BM patients, dose deficits >5% and >1% occurred in 2 GTV (2%) and 34 PTV (37%), respectively. The differences in target coverage showed a moderate-to-strong correlation only with barycenter shift. Local failure of at least one treated BM occurred in 13 (21%) patients and the 1-year and 2-year local control rates for all lesions were 94% and 90%, respectively. The implemented workflow ensured that the degradation of target and brain dose metrics in delivered treatments was negligible. Along with encouraging clinical outcomes, these findings warrant a reduction in the PTV margins at our institution.

17 September 2021 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
RLRaffaella Lucchini
Raffaella Lucchini
Denis PanizzaDenis Panizza
Denis Panizza
RCRiccardo Ray Colciago
Riccardo Ray Colciago
VVVeronica Vernier
Veronica Vernier
MDMartina Camilla Daniotti
Martina Camilla Daniotti
SAStefano Arcangeli
Stefano Arcangeli
Purpose/objectives: To report preliminary data on treatment outcome and compliance to dose-intensified organ sparing SBRT for prostate cancer using a novel electromagnetic transmitter-based tracking system (RayPilot® System) to account for intra-fractional organ motion. Material/methods: Thirteen patients with intermediate unfavorable (9) and selected high-risk (4) prostate cancer underwent dose-escalated SBRT in 4 or 5 fractions (BED1.5 = 279 Gy and 253 Gy, respectively). The VMAT treatment consisted in two 6FFF or 10FFF full arcs optimized to have the 95% isodose covering at least 95% of the PTV (2 mm isotropic expansion of the CTV). Whenever the real-time tracking registered a displacement that exceeded 2 mm during the setup and/or the beam delivery, the treatment was interrupted and the prostate motion was promptly corrected. The incidence of treatment-related genitourinary (GU) and gastrointestinal (GI) toxicity, patient QoL and PSA outcomes were computed from the start of treatment to the last follow-up date. Results: All patients completed the treatment in the expected time (10.2 +/− 4.2 minutes) and their compliance to the procedure was excellent. No clinically significant acute Grade 2 or higher GI (rectal) and GU side effects were observed within 90 days from the treatment completion. The median IPSS increased from 8 at baseline to 12 one-month after treatment and settled to 6 at 3 months. EPIC-26 scores in the urinary domain decreased from a median baseline of 86 pre-treatment to 79 at one-month and returned to baseline at a later timepoint (median score of 85 at 3 months). EPIC-26 scores in the bowel domains did not show significant changes within 3 months following RT. The prostate was found within 1 mm from its initial position in 78% of the beam-on time, between 1 and 2 mm in 20%, and exceeded 2 mm only in 2%, after correction for motion which was performed in 45% of the fractions, either during setup or beam delivery. Conclusions: Our preliminary findings show that dose intensified SBRT for unfavorable prostate tumors does not come at the cost of an increased toxicity, provided that a reliable technique for real time prostate monitoring is ensured. Fast FFF beams contributed to reduce intra-fractional motion. These observations need to be confirmed on a larger scale and a longer follow up.

4 July 2024 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
SAStefano Arcangeli
Stefano Arcangeli
CCChiara Chissotti
Chiara Chissotti
FFFederica Ferrario
Federica Ferrario
RLRaffaella Lucchini
Raffaella Lucchini
MBMaria Belmonte
Maria Belmonte
Denis PanizzaDenis Panizza
Denis Panizza

30 November 2022 in Current Oncology
Verified
Journal Article
Open access
PDF file
RLRaffaella Lucchini
Raffaella Lucchini
CFCiro Franzese
Ciro Franzese
SVSuela Vukcaj
Suela Vukcaj
GPGiorgio Purrello
Giorgio Purrello
Denis PanizzaDenis Panizza
Denis Panizza
SASTEFANO ARCANGELI
STEFANO ARCANGELI
Background: The aim of this study was to investigate the feasibility of ultrahypofractionated radiotherapy to the prostate bed in patients with biochemical and/or clinical relapse following radical prostatectomy who were enrolled in the prospective, observational, multicentric POPART trial (NCT04831970). Methods: Patients with post-radical prostatectomy PSA levels of ≥0.1–2.0 ng/mL and/or local relapse at PSMA PET/CT or multiparametric MRI were treated with Linac-based SBRT on the prostate bed up to a total dose of 32.5 Gy in five fractions every other day (EQD21.5 = 74.2 Gy). Maximum acute toxicity was assessed using the Common Terminology Criteria for Adverse Events version 5 scale. International Consultation on Incontinence Questionnaire—Short Form (ICIQ-SF) and Prostate Cancer Index Composite for Clinical Practice (EPIC-CP) scores were assessed at baseline and during the follow-up. Results: From April 2021 to June 2022, thirty men with a median age of 72 years (range 55–82) were enrolled in three centers. The median PSA level before RT was 0.30 ng/mL (range 0.18–1.89 ng/mL). At 3 months post-treatment, no GI or ≥2 GU side effects were reported; three patients (10%) experienced Grade 1 GU toxicity. No changes in ICIQ-SF or in the urinary domains of EPIC-CP were observed, while a transient worsening was registered in the bowel domain. At the same time point, all but two patients, who progressed distantly, were found to be biochemically controlled with a median post-treatment PSA level of 0.07 ng/mL (range 0–0.48 ng/mL). Conclusions: Our preliminary findings show that SBRT can be safely extended to the postoperative setting, without an increase in short-term toxicity or a significant decline in QoL. Long-term results are needed to confirm this strategy.