JIAN HU

Dr. JIAN HU


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
DCDanqian Cao
Danqian Cao
JHJIAN HU
JIAN HU
YLYue Li
Yue Li
SWStephen Wang
Stephen Wang
HLHongbin Liu
Hongbin Liu
To realize dexterous robotic manipulation and enhance the human-machine interaction, nowadays increasing efforts have been made towards multi-dimensional force sensing. However, there are still bottlenecks in integrating these sensors into robots because of the limitation on conformability to complex surfaces and miniaturization. To overcome the above challenges, we proposed a novel polymer-based waveguide tactile sensing method by embedding elastic optical waveguide channels into a 3D curved shell. By surrounding a soft tactel with four channels, the tactel is capable to measure normal and shear forces. We demonstrated that 3-axis force sensing is achieved on a shell structure with thickness of 2.1 mm. The average gauge factor in detecting the normal force from 0 to 1.1 N is −0.2207 N −1 , while the value is −0.1976 N −1 in the shear force sensing from −1 to 1 N. A force resolution of 0.1 mN has been achieved, and the proposed sensor has an average hysteresis of 22.23%. It performs well in dynamic force testing of 10 Hz and reaches average angle error 9.7357° and average amplitude error 0.1555 N between real force and predicted force which is derived by the calibration matrix. The experiment results prove that the proposed sensing method can provide triaxial force sensing on the complex 3D curved surface with good performance.

18 February 2020 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
CYChen Yu
Chen Yu
LLLukas Lindenroth
Lukas Lindenroth
JHJIAN HU
JIAN HU
JBJunghwan Back
Junghwan Back
GAGeorge Abrahams
George Abrahams
HLHongbin Liu
Hongbin Liu
Emulating a human-like somatosensory system in instruments such as robotic hands and surgical grippers has the potential to revolutionize these domains. Using a combination of different sensing modalities is problematic due to the limited space and incompatibility of these sensing principles. Therefore, in contrast to the natural world, it is currently difficult to concurrently measure the force, geometry, and temperature of contact in conventional tactile sensing. To this end, here we present a soft multifunctional tactile sensing principle. The temperature is estimated using a thermochromic liquid crystal ink layer which exhibits colour variation under temperature change. The shape and force of contact is estimated through the 3D reconstruction of a deformed soft silicone surface. Our experiments have demonstrated high accuracy in all three modalities, which can be measured at the same time. The resolution of the distributed force and temperature sensing was found to be 0.7N and 0.4°C respectively.

8 March 2024 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
YHYuanrui Huang
Yuanrui Huang
QZQingxiang Zhao
Qingxiang Zhao
JHJIAN HU
JIAN HU
HLHongbin Liu
Hongbin Liu
Magnetically-actuated continuum robots (MCRs) have the potential to be miniaturized to submillimeter sizes. However, their limited deformation modes hinder their ability to navigate through narrow and tortuous lumens. In this paper, we introduce a novel 2-degrees of freedom (DoF) MCR with diverse deformation modes. To validate the concept, a 20mm-long MCR is fabricated. We also present an optimization algorithm to expand the MCR's workspace, relying on a deformation estimation algorithm that has been experimentally proven to have an error of less than 1.15mm on the fabricated prototype. The optimized MCR exhibits a 40% larger workspace compared to conventional MCRs. Additionally, we integrate the 2-DoF MCR with mechanical devices and propose a Jacobian-based control scheme for them. Experimental results confirm its capability for tip trajectory tracking tasks with an RMS error of 0.71mm and demonstrate its ability for obstacle avoidance. These innovations hold significant implications for the development of MCRs, paving the way toward more efficient interventional procedures.

29 January 2024 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
XLXinran Liu
Xinran Liu
JCJian Chen
Jian Chen
JHJIAN HU
JIAN HU
HCHao Chen
Hao Chen
YHYuanrui Huang
Yuanrui Huang
HLHongbin Liu
Hongbin Liu
Robot-assisted minimally invasive surgery (MIS) using flexible endoscopy has emerged as a groundbreaking technology for improving traditional surgical approaches. However, a major challenge in advancing this technology is the lack of shape sensing, which leads to inaccurate navigation and control of ultra-long flexible endoscopy within the narrow and tortuous lumen environment. The unique characteristics of flexible endoscopy, including large slenderness ratio, high bending angles, and non-symmetric, multi-channel configurations, pose significant challenges to accurate shape sensing. To address this challenge, we propose a novel shape-sensing scheme based on distributed fiber optic strain measurement, which incorporates a complete and applicable multi-interface strain transfer model adapted to large deformation and multiple sensing points. To validate the theoretical model, a shape sensor with a diameter of 2.84 mm and a length of 500 mm is fabricated. Both 2D and 3D shape sensing experiments are conducted on predefined templates, and the results highlight a significant improvement in the precision of sensor measurements through the utilization of the proposed model. Specifically, the 3D experiment results show a mean absolute error (MAE) of 5.38 mm for complex geometrical shapes and the proposed model reduces the MAE by approximately 52.9% compared to the unmodified case.

13 March 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JHJIAN HU
JIAN HU
DCDanqian Cao
Danqian Cao
YLYue Li
Yue Li
HLHongbin Liu
Hongbin Liu
At present, most tactile sensors are fabricated based on the flat surface, which greatly limits their applications in the three-dimensional (3D) scenario. To deal with the bottleneck, this paper proposes a polymer-based optical waveguide sensing method. The waveguide can be integrally-formed along a channel within a 3D surface. Micro-bending light loss of a waveguide is the sensing principle. By studying the linearity between the degree of micro-bending and light loss, the feasibility analysis of spherical tactile sensing element (tactel) was completed, as well as the basis for size selection of it. In addition, the key to layout on 3D surface of the proposed sensing method is that the bending radius of the waveguide is within the critical angle of total internal reflection (TIR). By normalizing the ratio of the side length of the cross section to the bending radius, it is shown that the light loss does not increase when the proportionality coefficient is less than 0.3. The experiment is validated by embedding four tactels in a 3D surface. The cross section of the waveguide is 1.5mm x 1.5mm. We demonstrated that the static hysteresis error for a tactel is less than 16% within 595kPa, the best sensing sensitivity is 1.42 × 10 -5 kPa -1 , and the maximum measurement range is from 0 to 850kPa. As for the dynamic measurement, the tactel can rapidly response the signal change with given frequencies (the maximum is 10 Hz ). The average delay time is around 12ms.

5 April 2024 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
QZQingxiang Zhao
Qingxiang Zhao
SWShuai Wang
Shuai Wang
JHJIAN HU
JIAN HU
HLHongbin Liu
Hongbin Liu
HCHenry Kar Hang Chu
Henry Kar Hang Chu
Soft continuum robot arms (CRAs) are potential in narrow confined spaces owing to the high dexterity and compliance, while torsional motion is also anticipated in some scenarios in addition to omnidirectional bending. Most existing designs generate torsional motion either relying on an independent flexible shaft or with only a limited rotation range. This article presented a control scheme for a fully self-rotatable CRA, enabling concurrent rotation along the deformable backbone while positioning the end effector. Shape configuration acts as a bridge between actuation inputs and tip pose, where the bending and rotation motions are decoupled in kinematics. With an optimization-based algorithm and Jacobian-based online correction approach, the position of the tip could be well controlled and could cope with external disturbances. Both simulation and experiments demonstrate the effectiveness of the proposed model. Results indicate that the control scheme is applicable for conventional continuum robot designs and could also perform in-situ rotation, and the motion accuracy reached around $ \text{6}\,\text{mm}$ for the $ \text{120}\,\text{mm}$ length manipulator. A biopsy sampling experiment also demonstrates its potential in medical applications.