Dustin Geldrich Roberts

Dr. Dustin Geldrich Roberts

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SSShanmukha Srinivas
Shanmukha Srinivas
DRDustin Geldrich Roberts
Dustin Geldrich Roberts
JMJustin McWilliams
Justin McWilliams
LCLucas Cusumano
Lucas Cusumano
Background/Objectives: Microvascular plug embolization in the distal feeding artery (FA-MVP) and coil embolization targeting the nidus and feeding artery (NiFA-coil) are effective treatments for pulmonary arteriovenous malformations (PAVMs). This study compares their outcomes. Methods: A retrospective chart review was conducted on patients who underwent NiFA-coil or FA-MVP embolization for PAVMs between October 2014 and May 2024, with initial (short-term) follow-up chest CT imaging performed within 18 months, and the latest (long-term) follow-up performed at least 3 years post-treatment. Durable occlusion was defined as ≥70% shrinkage of the nidus or draining vein on follow-up CT. A Cox proportional hazards regression model assessed the association between technique and durable occlusion, with inverse propensity score weighting used to adjust for patient and PAVM characteristics. Results: A total of 142 PAVMs (48 FA-MVP, 94 NiFA-coil) in 85 patients were analyzed. Durable occlusion was 97.2% (138/142) at a median short-term follow-up of 4.2 months and 90.2% (37/41) at a median long-term follow-up of 56.0 months. Simple PAVMs were more frequent in the FA-MVP group (93.8%, 45/48) than in the NiFA-coil group (61.2%, 58/94) (p < 0.001). The NiFA-coil group had larger feeding arteries (3.8 mm vs. 2.3 mm, p < 0.001) and sac sizes (13.1 mm vs. 7.7 mm, p = 0.040). Short and long-term durable occlusion rates were comparable (NiFA-coil: 96.8% and 88.9%; FA-MVP: 97.8% and 92.9%, respectively; p > 0.99, p > 0.99). After propensity score matching, compared to FA-MVP, NiFA-coil had a hazard ratio for short-term persistence of 1.06 (95% CI, 0.16–6.99; p = 0.956). Conclusions: Both NiFA-coil and FA-MVP embolization are highly effective for PAVM treatment, with similar success rates.

3 February 2025 in PLOS ONE
Verified
Journal Article
Open access
PDF file
NCNand Chandravadia
Nand Chandravadia
SPShrita Pendekanti
Shrita Pendekanti
DRDustin Geldrich Roberts
Dustin Geldrich Roberts
RTRobert Tran
Robert Tran
SPSaarang Panchavati
Saarang Panchavati
WSWilliam Speier
William Speier
The P300 Speller is a brain-computer interface system that allows victims of motor neuron diseases to regain the ability to communicate by typing characters into a computer by thought. Since the system has a relatively slow typing speed, different stimulus presentation paradigms have been proposed designed to allow users to input information faster by reducing the number of required stimuli or increase signal fidelity. This study compares the typing speeds of the Row-Column, Checkerboard, and Combinatorial Paradigms to examine how their performance compares in online and offline settings. When the different flashing patterns were tested in conjunction with other established optimization techniques such as language models and dynamic stopping, they did not make a significant impact on P300 speller performance. This result could indicate that further performance improvements on the system lie beyond optimizing flashing patterns.

29 March 2019 in Journal of Medical Imaging and Radiation Oncology
Verified
Journal Article
Closed access
PDF file
DRDustin Geldrich Roberts
Dustin Geldrich Roberts
APAdam N Plotnik
Adam N Plotnik
JCJeffrey Fb Chick
Jeffrey Fb Chick
RSRavi N Srinivasa
Ravi N Srinivasa

23 January 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SMSipan Mathevosian
Sipan Mathevosian
SSSparks Sparks
Sparks Sparks
LCLucas Cusumano
Lucas Cusumano
DRDustin Geldrich Roberts
Dustin Geldrich Roberts
SMShamaita Majumdar
Shamaita Majumdar
JMJustin McWilliams
Justin McWilliams
Embolization of de novo pulmonary arteriovenous malformations (PAVMs) using high-volume detachable non-fibered (HVDNF) coils was compared to traditional non-HVDNF coils. Persistent-occlusion rates were evaluated. A total of 272 de novo (previously untreated) PAVM treatments were retrospectively stratified into those treated with non-HVDNF coils only (n = 192) and those treated with HVDNF coils with or without other coils (n = 80). Propensity score matching, followed by survival analysis and cost analysis, was performed. The overall persistent-occlusion rate was 86.0% (234/272). Persistent occlusion was achieved in 81.8% of PAVMs using non-HVDNF coils, compared with 96.3% using HVDNF coils (p = 0.0017). The mean follow-up was 30.7 ± 31.9 months versus 14.7 ± 13.4 months, respectively (p < 0.0001). Propensity-matched survival analysis demonstrated PAVMs treated with HVDNF coils recurred significantly less frequently than PAVMs treated with non-HVNDF coils (p = 0.023). The use of HVDNF coils was more expensive than standard coils, however not significantly different for the treatment of complex PAVMs. The use of high-volume detachable non-fibered coils was associated with higher persistent-occlusion rates when compared with non-HVDNF coils. HVDNF coils were more expensive on average; however, cost was similar between groups for the treatment of complex PAVMs.

1 August 2020 in Urology
Verified
Journal Article
Closed access
DRDustin Geldrich Roberts
Dustin Geldrich Roberts
RPRicky B. Patel
Ricky B. Patel
SGScott J. Genshaft
Scott J. Genshaft
SPSiddharth A. Padia
Siddharth A. Padia
JMJustin P. McWilliams
Justin P. McWilliams
RSRavi N. Srinivasa
Ravi N. Srinivasa

1 December 2021 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Closed access
DRDustin Geldrich Roberts
Dustin Geldrich Roberts
LCLucas Cusumano
Lucas Cusumano
JMJustin McWilliams
Justin McWilliams