The utility of Doppler parameters and waveform contour analysis for diagnosis of renal artery stenosis was studied in a hypertensive population screened for renovascular hypertension. The Doppler results were compared with those obtained with angiography in a prospective double-blind study involving 118 kidneys in 46 patients with hypertension and 11 potential renal donors with normal blood pressure. Doppler parameters measured in the distal renal artery included systolic acceleration, acceleration time, peak systolic velocity, deceleration in late systole, pulsatility and resistivity indexes, and waveform features in early systole. Angiograms demonstrated 28 stenotic renal arteries. There was no significant difference between stenotic (> 50% diameter narrowing) and nonstenotic renal arteries for any parameters studied. When stenosis was further categorized as moderate (50%-79%) or severe (80%-95%), significant (P < .05) differences for acceleration time and systolic acceleration were found between nonstenotic and severely stenotic arteries. Doppler characterization of the tardus-parvus phenomenon in the distal renal artery is not an adequate screening method for detection of renal artery stenosis.
1 September 1998 in International Journal of Radiation Oncology, Biology, Physics
To describe the cortical tangential approach to ultrasonographically (US) guided renal transplant biopsy and evaluate its efficacy in obtaining sufficient cortical tissue. This HIPAA-compliant retrospective study was exempted from review by the institutional review board. Informed consent was not required. The number of core biopsy samples, glomeruli, and small arteries obtained during 294 consecutive US-guided renal transplant biopsies in 254 patients (134 men, 120 women; age range, 19-79 years; mean age, 52.2 years) in one department between June 1 and December 31, 2008, were recorded, along with any ensuing complications. Procedural success was assessed according to Banff 97 criteria. There were 1.2 +/- 0.4 (standard deviation) biopsy core samples taken per case by 11 radiologists using the cortical tangential approach. In 290 cases, biopsy results showed 21.7 +/- 10.1 glomeruli and 5.0 +/- 2.8 small arteries. Two hundred seventy-six (95%) cases were adequate or minimal according to Banff 97 assessment criteria. Of the 14 inadequate cases (5%), six were lacking only one glomerulus to achieve minimal status. Only one biopsy core sample was taken in all 14 inadequate cases and in 233 successful cases (success rate, 85%). None of the 43 cases with two or more biopsy core samples taken were inadequate (success rate, 100%). Two patients (0.7%) had a hemorrhagic complication requiring transfusion, and another four patients (1.4%) experienced a minor self-limiting complication. The cortical tangential approach can be used by a cohort of radiologists to achieve 95% or higher collective success in obtaining cortical tissue during renal transplant biopsy, with few complications. The success rate is higher, without increased complications, when more than one core specimen is taken.
12 March 2009 in CardioVascular and Interventional Radiology
Aluminum toxicity in patients undergoing dialysis currently requires bone biopsy for definitive diagnosis. The authors retrospectively reviewed clinical, histologic, and radiographic findings in 63 patients undergoing dialysis. In 30 patients, biopsy specimens were negative for aluminum toxicity, and in 33 patients, specimens were positive. In 21 of the 30 patients who had a negative biopsy specimen, absence of aluminum toxicity could be predicted by a high immunoreactive parathyroid hormone level (greater than 2,000 microliter Eq/ml [2,210 pM]) and fewer than three fractures, by the presence of osteosclerosis on radiographs, or if serum aluminum levels were less than 30 ng/ml. None of the patients who had a positive biopsy specimen met these criteria. In 18 of 33 patients who had a positive biopsy specimen, aluminum toxicity could be predicted by a low immunoreactive parathyroid hormone level (less than 500 microliter Eq/ml [553 pM]) and more than three fractures, or if serum aluminum levels were greater than 300 ng/ml. None of the patients who had a negative biopsy specimen met these criteria. Thus, based on the criteria identified, the aluminum status of 62% of these patients would have been correctly diagnosed.