Chiara Zandonà

Dr. Chiara Zandonà

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019
Verified
Conference Paper
Closed access
GMGiovanni Menegozzo
Giovanni Menegozzo
DDDiego DallrAlba
Diego DallrAlba
CZChiara Zandonà
Chiara Zandonà
PFPaolo Fiorini
Paolo Fiorini
DDDiego Dall'Alba
Diego Dall'Alba
Automatic gesture recognition during surgical procedures is an enabling technology for improving advanced assistance features in surgical robotic systems (SRSs). Examples of such advanced features are user-specific feedback during execution of complex actions, prompt detection of safety-critical situations and autonomous execution of procedure sub-steps. Video data are available for all minimally invasive surgical procedures, but SRS could also provide accurate movements measurements based on kinematic data. Kinematic data provide low dimensional features for gesture recognition that would enable on-line processing during data acquisition. Therefore, we propose a Time Delay Neural Network (TDNN) applied to kinematic data for introducing temporal modelling in gesture recognition. Wee valuate accuracy and precision of the proposed method on public benchmark dataset for surgical gesture recognition (JIGSAWS). To evaluate the generalization capability of the proposed method, we acquired a new dataset intruding a different training exercise executed in virtual environment.The dataset is publicly available to enable other methods to be tested on it. The obtained results are comparable with other methods available in literature keeping also computational performance compatible with on-line processing during surgical procedure. The proposed method and the novel dataset are key-components in the development of future autonomous SRSs with advanced situation awareness capabilities.

1 March 2024 in Technologies
Verified
Journal Article
Open access
PDF file
CZChiara Zandonà
Chiara Zandonà
ARAndrea Roberti
Andrea Roberti
DCDavide Costanzi
Davide Costanzi
BGBurcin Gul
Burcin Gul
ÖAÖzge Akbulut
Özge Akbulut
ACAndrea Calanca
Andrea Calanca
Transperineal prostate biopsy is the most reliable technique for detecting prostate cancer, and robot-assisted needle insertion has the potential to improve the accuracy of this procedure. Modeling the interaction between a bevel-tip needle and the tissue, considering tissue heterogeneity, needle bending, and tissue/organ deformation and movement is a required step to enable robotic needle insertion. Even if several models exist, they have never been compared on experimental grounds. Based on this motivation, this paper proposes an experimental comparison for kinematic models of needle insertion, considering different needle insertion speeds and different degrees of tissue stiffness. The experimental comparison considers automated insertions of needles into transparent silicone phantoms under stereo-image guidance. The comparison evaluates the accuracy of existing models in predicting needle deformation.