Very-high-frequency (VHF) electromagnetic signals have been well used to image lightning channels with high temporal and spatial resolution due to their capability to penetrate clouds. A lightning broadband VHF interferometer with three VHF antennas configured in a scalene-triangle shape has been installed in Lhasa since 2019, to detect the lightning VHF signals. Using the signals from the VHF interferometer, a new hybrid algorithm, called the TDOA-EMTR technique, combining the time difference of arrival (TDOA) and the electromagnetic time reversal (EMTR) technique is introduced to image the two-dimensional lightning channels. The TDOA technique is firstly applied to calculate the initial solutions for the whole lightning flash. According to the results by the TDOA method, the domain used for the EMTR technique is predetermined, and then the EMTR technique is operated to obtain the final positioning result. Unlike the original EMTR technique, the low-power frequency points for each time window are removed based on the FFT spectrum. Metrics used to filter noise events are adjusted. Detailed imaging results of a negative cloud-to-ground (CG) lightning flash and an intra-cloud (IC) lightning flash by the TDOA method and the TDOA-EMTR are presented. Compared with the original EMTR method, the positioning efficiency can be improved by more than a factor of 3 to 4, depending on the scope of the pre-determined domain. Results show that the new algorithm can obtain much weaker radiation sources and simultaneously occurring sources, compared with the TDOA method.
Lightning stroke strength, characterized by energy and peak currents, over the Tibetan Plateau (TP), is investigated by utilizing datasets from the World Wide Lightning Location Network and the Chinese Cloud-to-Ground Lightning Location System during 2016–2019. Focused on the south-central (SC) and southeast (SE) of the TP, it reveals that SE-TP experiences strokes with larger average energy and peak currents. Strong strokes (energy ≥ 100 kJ or peak currents ≥ |100| kA), exhibiting bimodal distribution in winter and summer, are more frequent and have larger average values over the SE-TP than the SC-TP, with diurnal distribution indicating peaks in energy and positive strokes in the middle of the night and negative strokes peaking in the morning. Utilizing the ECMWF/ERA-5 and MERRA-2 reanalysis, we find that stronger strokes correlate with thinner charge zone depths and larger CIWCFs but stable warm cloud depths and zero-degree levels over the SC-TP. Over the SE-TP, stronger strokes are associated with smaller CIWCFs and show turning points for warm cloud depths and zero-degree levels. Thicker charge zone depths correlate with stronger negative strokes but weaker positive strokes. Generating strokes of similar strength over the SC-TP requires larger CIWCFs, thinner warm cloud depths, and lower zero-degree levels than over the SE-TP.