Aidan Comeau

Mr. Aidan Comeau

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2021 in Journal of Applied Gerontology
Verified
Journal Article
Open access
PDF file
ARAdriana María Ríos Rincón
Adriana María Ríos Rincón
ACAntonio Miguel Cruz
Antonio Miguel Cruz
CDChristine Daum
Christine Daum
NNNoelannah Neubauer
Noelannah Neubauer
ACAidan Comeau
Aidan Comeau
LLLili Liu
Lili Liu
The rates of dementia are on the rise as populations age. Storytelling is commonly used in therapies for persons living with dementia and can be in the form of life review, and reminiscence therapy. A systematic literature review was conducted to examine the range and extent of the use of digital technologies for facilitating storytelling in older adults and their care partners, and to identify the processes and methods, the technologies used and their readiness levels, the evidence, and the associated outcomes. Eight electronic databases were searched: Medline, EMBASE, PsycINFO, CINAHL, Abstracts in Social Gerontology, ERIC, Web of Science, and Scopus. We included 34 studies. Mild cognitive impairment or dementia represented over half of medical conditions reported in the studies. Overall, our findings indicate that the most common use of digital storytelling was to support older adults’ memory, reminiscence, identity, and self-confidence; however, the level of evidence of its effectiveness was low.

Verified
Journal Article
Open access
PDF file
ACAidan Comeau
Aidan Comeau
KJKelvin E. Jones
Kelvin E. Jones
EPEric C. Parent
Eric C. Parent
MKMichael D. Kennedy
Michael D. Kennedy
The impact of exercise-specific face masks (ESFMs) in aerobically fit individuals on physiological, perceptual, respiratory, and performance responses remains unclear. How ESFMs mitigate exercise-induced bronchoconstriction (EIB) is also unknown. Thus, this study aimed to determine how an ESFM altered within-exercise physiological, perceptual, respiratory, and performance responses to graded treadmill exercise. Twenty-four individuals (11 females) completed a discontinuous graded exercise test on a treadmill under two conditions (ESFM and unmasked). Physiological, respiratory function, and perceptual measures were assessed. Performance was determined by time to exhaustion. Statistical analyses included linear mixed-effects modeling, repeated measures analysis of variance, and pairwise comparisons using an alpha value of 0.05. ESFM use significantly impaired performance (median = −150.5 s) and decreased arterial oxygen saturation at maximal intensity (mean = −3.7%). Perceptions of air hunger and work of breathing were elevated across submaximal and maximal intensities. Perceived exertion and breathing discomfort were significantly elevated submaximally but not maximally. Spirometry measures were not significantly different at termination but were significantly improved at submaximal intensities in participants with and without EIB. ESFM use in fit individuals increased perceptual discomfort, impaired performance, and augmented arterial desaturation. Respiratory function improvements were observed but were accompanied by adverse perceptual sensations. Despite this, performance impairments may limit the real-world utility of ESFMs for athletes.

6 September 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JNJoao Henrique Falk Neto
Joao Henrique Falk Neto
NBNormand Boulé
Normand Boulé
KJKelvin E Jones
Kelvin E Jones
ACAidan Comeau
Aidan Comeau
MKMichael D Kennedy
Michael D Kennedy
Determining an athlete’s maximal peak power (MPP) is crucial in profiling endurance sports participants. While short (3 to 6 seconds) all-out efforts have been validated for MPP assessment, prior studies mainly involved non-endurance trained athletes. This study aimed to assess the intra- and inter-day reliability of a 6-second Wingate test for MPP determination in endurance athletes. Endurance-trained participants (22 males, 5 females) completed nine 6-second Wingate tests over four days (3 trials at baseline, 2 trials on each subsequent day). Analysis revealed no systematic differences in MPP (F(4.09, 106.3) = 1.88, p = 0.117) or time to peak power (χ2(8) = 5.23, p = 0.732) across the trials. Reliability, assessed through the intraclass correlation coefficient (ICC) and standard error of measurement (SEM), was excellent across all trials (ICC = 0.95, SEM = 40.0W, SEM% = 3.7%). Absolute reliability improved when selecting the average or the best MPP values from each day (SEM% = 2.7% and 2.9%, respectively). Within-day reliability was consistently rated as excellent, with the best values on the 4thday of tests. No significant differences in MPP values occurred between the first and second 6-second Wingate tests on days 1 to 3, with both trials demonstrating similar reliability values (SEM%: 3.2% vs 2.8%, for the first and second trials, respectively). The test also demonstrated a good sensitivity to detect a meaningful change in MPP values. In conclusion, the 6-second Wingate test proves reliable for determining MPP in endurance-trained athletes. Two trials are recommended on the first day of testing, with a single MPP likely sufficient to determine the athlete’s MPP on subsequent days.