Yisen Wang

Mr. Yisen Wang

Mechanical Engineering, University of Wisconsin–Madison, Madison, Alabama, USA
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2023 in Current Opinion in Biomedical Engineering
Verified
Journal Article
Closed access
Peter AdamczykPeter Adamczyk
Peter Adamczyk
SHSara E. Harper
Sara E. Harper
ARAlex J. Reiter
Alex J. Reiter
RRRebecca A. Roembke
Rebecca A. Roembke
Yisen WangYisen Wang
Yisen Wang
DTDarryl G. Thelen
Darryl G. Thelen

24 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Yisen WangYisen Wang
Yisen Wang
Katherine Heidi FehrKatherine Heidi Fehr
Katherine Heidi Fehr
Peter AdamczykPeter Adamczyk
Peter Adamczyk
Motion reconstruction using wearable sensors enables broad opportunities for gait analysis outside laboratory environments. Inertial Measurement Unit (IMU)-based foot trajectory reconstruction is an essential component of estimating the foot motion and user position required for any related biomechanics metrics. However, limitations remain in the reconstruction quality due to well-known sensor noise and drift issues, and in some cases, limited sensor bandwidth and range. In this work, to reduce drift in the height direction and handle the impulsive velocity error at heel strike, we enhanced the integration reconstruction with a novel kinematic model that partitions integration velocity errors into estimates of acceleration bias and heel strike vertical velocity error. Using this model, we achieve reduced height drift in reconstruction and simultaneously accomplish reliable terrain determination among level ground, ramps, and stairs. The reconstruction performance of the proposed method is compared against the widely used Error State Kalman Filter-based Pedestrian Dead Reckoning and integration-based foot-IMU motion reconstruction method with 15 trials from six subjects, including one prosthesis user. The mean height errors per stride are 0.03±0.08 cm on level ground, 0.95±0.37 cm on ramps, and 1.27±1.22 cm on stairs. The proposed method can determine the terrain types accurately by thresholding on the model output and demonstrates great reconstruction improvement in level-ground walking and moderate improvement on ramps and stairs.

1 December 2019
Verified
Conference Paper
Closed access
KTKun Tan
Kun Tan
HSHu Shi
Hu Shi
Yisen WangYisen Wang
Yisen Wang
LYLin Yang
Lin Yang
In this paper, a novel 4-DOF parallel surgical robot with parallelogram remote center-of-motion mechanism is proposed for transurethral resection of bladder tumors in urology. The emergence of minimally invasive surgery robots has enabled surgeons to achieve more dexterous and more reliable surgical procedures, but general surgical robot platforms have some shortcomings, such as high cost and complicated maintenance, which is not conducive to promotion in a wide range. Based on analysis of the manual operation characteristics of the surgeons in the current operation, the kinematics model of the surgical tool with D-H coordinates is established, and the Jacobian matrix of the cutting points in the instantaneous motion analysis is solved. A robotic arm scheme, including parallelogram remote center-of-motion mechanism, rope drive module and parallel actuator module, is designed. A kinematic model of the surgical robot is established. A calculation method of Jacobian matrix with numerical methods is provided. The Kinematic Conditioning Index defined to measure the operational dexterity of the robot in the global and local space is described. With the index as the optimization goal, optimized selection of parameters and configurations are performed. And the final physical model of surgical robot is shown. The novel surgical robot system can maintain good surgical performance, while greatly reducing system development costs and complexity.

2 December 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JAJulian Acasio
Julian Acasio
Yisen WangYisen Wang
Yisen Wang
Katherine Heidi FehrKatherine Heidi Fehr
Katherine Heidi Fehr
BHBrad D Hendershot
Brad D Hendershot
Peter AdamczykPeter Adamczyk
Peter Adamczyk
Monitoring mobility outcomes in real-world environments can provide a distinct perspective compared to traditional outcome measures obtained in laboratory or clinical settings, which may be limited by environmental factors or behavioral modification. Here, we present an ecologically valid framework for collecting mobility outcomes in everyday life by utilizing prosthesis-mounted wearable sensors. The custom sensor suite, consisting of five inertial measurement units, GPS, and environmental sensors, was worn by 14 individuals with unilateral transtibial amputation for approximately 4 weeks each. Across the monitoring period, 49,577 ± 30,468 (mean ± SD) strides were identified per participant (~10.2 sensor-hours per day). Strides were characterized according to walking bout duration, with most walking observed in relatively short walking bouts (<30 s) at slow walking speeds (~0.5 m/s). Turns were identified and characterized by magnitude, direction, strides, and time taken to complete. The percentage of prosthetic-inside turns was around 50% for less than 90° turns, but higher turn angles showed bias toward prosthetic-outside turns, on average. Most individual participants showed bias toward one direction or the other. Participants also averaged ~28.3 stair-steps per sensor-day. Stair-steps were biased toward upstairs (vs. downstairs) walking and toward step-over-step (vs. step-by-step) strategies. Collectively, these data provide a uniquely detailed evaluation of locomotion behaviors among persons with lower limb loss in everyday living. Future work could utilize the ecological framework described here for establishing functional benchmarks, assisting with device prescription, and otherwise guiding long-term care for optimizing mobility outcomes and quality of life after lower limb loss.