Electrical submersible pumping is the most inflexible of any artificial lift system because a specific ESP pump can only be used in a definite, quite restricted range of pumping rates. If it is used outside the specified range, pump and system efficiencies rapidly deteriorate and eventually mechanical problems leading to a complete system failure develop. When serious deviation from the design production rate is experienced, the possible solutions are (a) running a different pump with the proper recommended operating range, or (b) using a variable speed drive (VSD) unit. However, in case the ESP system produces a higher than desired liquid rate, a simple and frequently used solution is the installation of a wellhead choke. The wellhead choke restricts the pumping rate and forces the ESP pump to operate within its recommended liquid rate range. This solution, of course, is very detrimental to the economy of the production system because of the high hydraulic losses across the choke that cause a considerable waste of energy. The paper utilizes NODAL analysis to investigate the negative effects of surface production chokes on the energy efficiency of ESP systems as compared to the application of VSD drives. The power flow in the ESP system is described and the calculation of energy losses in system components is detailed. Based on these, a calculation model is proposed to evaluate the harmful effects of wellhead choking and to find the proper parameters of the necessary VSD unit. By presenting a detailed calculation on an example well using the proposed model the detrimental effects of wellhead choking are illustrated and the beneficial effects of using a VSD drive are presented. Using data of a group of wells placed on ESP production a detailed investigation is presented on the field-wide effects of choking. The energy flows and the total energy requirements are calculated for current and optimized cases where VSD units providing the required electrical frequencies are used. Final results clearly indicate that substantial electric power savings are possible if production control is executed by VSDs instead of the present practice of using surface chokes.
30 May 2015 in Journal of Petroleum Exploration and Production Technology
Power requirements and profitability of sucker-rod pumping are basically determined by the torque load on the pumping unit’s gearbox. Gearbox torques include the torque required to drive the polished rod and the torque used to rotate the counterweights. In addition to these, inertial torques arise in those parts of the pumping unit that turn at varying speeds. As shown in the paper, all torque components are functions of the crank angle; consequently, their exact calculation necessitates the knowledge of the crank angle versus time function. This circumstance, however, complicates torque calculations because contemporary dynamometers, used to acquire the necessary operating data, do not provide any information on the variation of the crank angle during the pumping cycle. The paper introduces a solution of the problem and presents an iterative calculation of the crank angle versus time function from dynamometer data. Based on this function crank velocity, crank acceleration, as well as beam acceleration can be calculated and all necessary gearbox torques can be evaluated. For calculating articulating inertial torque, the acceleration pattern of the walking beam during the pumping cycle is evaluated according to three different models and the accuracy of those is compared. The paper gives the details of the developed calculation models and presents a typical sample case.
1 November 2019 in Journal of Petroleum Science and Engineering
Summary: Two of the most important artificial-lift methods applied in oil wells are sucker-rod pumping (SRP) and electrical submersible pumping (ESP, with thousands of installations all over the world. Their operational features and application ranges are quite different, but in many cases either of them can be used in a given well. The final selection of the proper method has to be on the basis of energy efficiency, and the one requiring the least amount of surface power input is selected. This paper provides the necessary background for evaluating the effectiveness of the two lift methods investigated and for pinpointing the requirements of achieving maximum power efficiency of artificial lifting. The power flow in the pumping system is investigated, and the sources of power losses, along with their usual ranges, are described. The overall power efficiency of the system is defined by a simple formula that provides the necessary insight into the main components of the power losses occurring in different system elements. A thorough investigation of the efficiency components allows one to find the factors that most markedly influence the total system's power requirement. As shown in the paper, the most important requirement for achieving maximum effectiveness is the proper choice of the pumping mode (i.e., the combination of plunger size, stroke length, and pumping speed). The calculation of energy losses in the components of the ESP system is detailed, and the relative importance of the individual losses is shown. Because the components of the ESP system are connected in series, a relatively simple formula can be used to describe the effect of electrical and hydraulic losses on the efficiency of the total system. The terms of the final formula were investigated for their importance and contribution to the overall effectiveness of the ESP system. Results of this investigation provide crucial information that explain how to design an ESP system that provides the highest power efficiency. The practical use of the proposed calculation models is illustrated by presenting an example case where a relatively high liquid rate (1,300 B/D) from the same well is produced by rod pumping and by ESP. Detailed installation designs resulted in several different operation modes for both SRP and ESP. The paper demonstrates that using the latest technologies (e.g., high-strength sucker-rod connections), SRP can compete successfully with ESP installations by attaining higher energy efficiencies.