Prakash Adhikari

Dr. Prakash Adhikari


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2015 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
PAPrakash Adhikari
Prakash Adhikari
AZAndrew J. Zele
Andrew J. Zele
BFBeatrix Feigl
Beatrix Feigl
Purpose.: The post-illumination pupil response (PIPR) has been quantified using four metrics, but the spectral sensitivity of only one is known; here we determine the other three. To optimize the human PIPR measurement, we determine the protocol producing the largest PIPR, the duration of the PIPR, and the metric(s) with the lowest coefficient of variation. Methods.: The consensual pupil light reflex (PLR) was measured with a Maxwellian view pupillometer. Experiment 1: Spectral sensitivity of four PIPR metrics (plateau, 6 seconds, area under curve early and late recovery) was determined from a criterion PIPR to a 1-second pulse and fitted with vitamin A1 nomogram (λmax = 482 nm). Experiment 2: The PLR was measured as a function of three stimulus durations (1 second, 10 seconds, 30 seconds), five irradiances spanning low to high melanopsin excitation levels (retinal irradiance: 9.8–14.8 log quanta.cm−2.s−1), and two wavelengths, one with high (465 nm) and one with low (637 nm) melanopsin excitation. Intra- and interindividual coefficients of variation (CV) were calculated. Results.: The melanopsin (opn4) photopigment nomogram adequately describes the spectral sensitivity of all four PIPR metrics. The PIPR amplitude was largest with 1-second short-wavelength pulses (≥12.8 log quanta.cm−2.s−1). The plateau and 6-second PIPR showed the least intra- and interindividual CV (≤0.2). The maximum duration of the sustained PIPR was 83.0 ± 48.0 seconds (mean ± SD) for 1-second pulses and 180.1 ± 106.2 seconds for 30-second pulses (465 nm; 14.8 log quanta.cm−2.s−1). Conclusions.: All current PIPR metrics provide a direct measure of the intrinsic melanopsin photoresponse. To measure progressive changes in melanopsin function in disease, we recommend that the PIPR be measured using short-duration pulses (e.g., ≤1 second) with high melanopsin excitation and analyzed with plateau and/or 6-second metrics. Our PIPR duration data provide a baseline for the selection of interstimulus intervals between consecutive pupil testing sequences.

1 July 2019 in Vision Research
Verified
Journal Article
Closed access
AZAndrew J. Zele
Andrew J. Zele
PAPrakash Adhikari
Prakash Adhikari
DCDingcai Cao
Dingcai Cao
BFBeatrix Feigl
Beatrix Feigl

2 December 2011 in Journal of Ocular Pharmacology and Therapeutics
Verified
Journal Article
Closed access
Himal KandelHimal Kandel
Himal Kandel
PAPrakash Adhikari
Prakash Adhikari
GSGauri S. Shrestha
Gauri S. Shrestha
EREeva-Liisa Ruokonen
Eeva-Liisa Ruokonen
DSDev Narayan Shah
Dev Narayan Shah
Purpose: Aim of the study was to evaluate the effects of ethambutol therapy in visual functions. Methods: Prospective evaluation of 88 eyes of 44 patients on ethambutol therapy under Directly Observed Treatment Short-course (category I) for primary tuberculosis was done before start of ethambutol therapy and after 2 months of starting the therapy. Parameters evaluated were visual acuity with Bailey Lovie Log-MAR chart, contrast sensitivity with Pelli-Robson contrast sensitivity chart, color vision with Farnsworth D15 test, visual fields with Octopus automated perimetry, and multifocal electroretinography (ERG) with Roland-RETI scan along with anterior and posterior segments evaluation. Results: No visual functional defect was noted at baseline. On follow-up, color vision, visual field parameters, and anterior and posterior segment findings were not affected in any patients. Mean visual acuity before starting therapy was 0.00±0.08 Log-MAR and after therapy was 0.08±0.18 Log-MAR. Change in visual acuity was statistically significant ( p =0.004). Difference between contrast sensitivity before and after therapy was statistically highly significant both monocularly and binocularly ( p <0.005 in both cases). P1 amplitudes (in terms of nV/deg 2 and μV) of ERG waves were significantly reduced and their P1 latencies were significantly increased in all the rings after ethambutol therapy ( p <0.05). There was no significant change in N1 amplitudes and N1 latencies after therapy in any of the rings. Conclusions: Visual acuity, contrast sensitivity, and multifocal ERG are sensitive tests to detect ethambutol toxicity in subclinical stages and hence very useful tools for monitoring patients under ethambutol therapy for ocular toxicity.

20 December 2019 in Journal of Sleep Research
Verified
Journal Article
Closed access
PDF file
DJDaniel S. Joyce
Daniel S. Joyce
AZAndrew J. Zele
Andrew J. Zele
BFBeatrix Feigl
Beatrix Feigl
PAPrakash Adhikari
Prakash Adhikari

1 March 2010 in Clinical and Experimental Optometry
Verified
Journal Article
Closed access
PDF file
NPNabin Paudel
Nabin Paudel
SLSusan Jennifer Leat
Susan Jennifer Leat
PAPrakash Adhikari
Prakash Adhikari
JWJ Margaret Woodhouse
J Margaret Woodhouse
JSJyoti Baba Shrestha
Jyoti Baba Shrestha

25 June 2021 in Journal of the Optical Society of America A
Verified
Journal Article
Closed access
PDF file
SUSamir Uprety
Samir Uprety
AZAndrew J. Zele
Andrew J. Zele
BFBeatrix Feigl
Beatrix Feigl
DCDingcai Cao
Dingcai Cao
PAPrakash Adhikari
Prakash Adhikari
The intrinsic melanopsin photoresponse may initiate visual signals that differ in spatiotemporal characteristics from the cone-opsin- and rhodopsin-mediated signals. Applying the CIE standard observer functions in silent-substitution methods can require individual differences in photoreceptor spectral sensitivities and pre-receptoral filtering to be corrected; failure to do so can lead to the intrusion of more sensitive cone processes with putative melanopsin-directed stimuli. Here we evaluate heterochromatic flicker photometry (HFP) and photoreceptor-directed temporal white noise as techniques to limit the effect of these individual differences. Individualized luminous efficiency functions (V(λ)) were compared to the CIE standard observer functions. We show that adapting chromaticities used in silent-substitution methods can deviate by up to 54% in luminance when estimated with the individual and standard observer functions. These deviations lead to inadvertent cone intrusions in the visual functions measured with melanopsin-directed stimuli. To eliminate the intrusions, individual HFP corrections are sufficient at low frequencies (∼1Hz) but temporal white noise is also required at higher frequencies to desensitize penumbral cones. We therefore recommend the selective application of individualized observer calibration and/or temporal white noise in silent-substitution paradigms when studying melanopsin-directed photoresponses.