Siamak Noroozi

Prof. Dr. Siamak Noroozi


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 March 2012 in Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology
Verified
Journal Article
Closed access
SNSiamak Noroozi
Siamak Noroozi
PSPhilip Sewell
Philip Sewell
ARAbdul Ghaffar Abdul Rahman
Abdul Ghaffar Abdul Rahman
JVJohn Vinney
John Vinney
ZOZhi Chao Ong
Zhi Chao Ong
BDBryce Dyer
Bryce Dyer
The desire of individuals with a lower-limb amputation to participate in sports, coupled with the high demands of athletics, has resulted in the development of energy-storing-and-returning feet, capable of storing energy during stance and returning it to the individual in late stance to assist in forward propulsion. However, little attention has been paid to date to advance the understanding of their dynamic characteristics (natural frequencies, mode shapes and damping) during running. The evaluation of such parameters is now urgently required, as the use of energy-storing-and-returning feet is now being investigated through legal and justice systems to determine participation of amputee athletes using them at the Olympic Games. This paper presents a study of the dynamic characteristics of two commercially available Elite Blade composite feet (solid and split foot). A full modal analysis of the feet was conducted with varying masses attached to them, representing different body masses. The study showed that natural frequencies close to typical running step frequency can be achieved with simple control of the mass or stiffness. It was concluded that further study of the dynamic characteristics could result in a significant change in the design, development and the attitude towards the use of composite prosthetic feet. This initial study has highlighted the key questions that need to be answered to fully understand the dynamic characteristics and inform designers on how to tune a foot to match an amputee’s gait and body condition.

1 February 2019 in Prosthetics and Orthotics International
Verified
Journal Article
Closed access
SNSiamak Noroozi
Siamak Noroozi
ZOZhi Chao Ong
Zhi Chao Ong
SKShin Yee Khoo
Shin Yee Khoo
NANavid Aslani
Navid Aslani
PSPhilip Sewell
Philip Sewell
The current method of prescribing composite running-specific energy-storing-and-returning feet is subjective and is based only on the amputee’s static body weight/mass. The aim was to investigate their dynamic characteristics and create a relationship between these dynamic data and the prescription of foot. Experimental Assessment. This article presents the modal analysis results of the full range of Össur Flex-Run™ running feet that are commercially available (1LO–9LO) using experimental modal analysis technique under a constant mass at 53 kg and boundary condition. It was shown that both the undamped natural frequency and stiffness increase linearly from the lowest to the highest stiffness category of foot which allows for a more informed prescription of foot when tuning to a matched natural frequency. The low damping characteristics determined experimentally that ranged between 1.5% and 2.0% indicates that the feet require less input energy to maintain the steady-state cyclic motion before take-off from the ground. An analysis of the mode shapes also showed a unique design feature of these feet that is hypothesised to enhance their performance. A better understanding of dynamic characteristics of the feet can help tune the feet to the user’s requirements in promoting a better gait performance. The dynamic data determined from this study are needed to better inform the amputees in predicting the natural frequency of the foot prescribed. The amputees can intuitively tune the cyclic body rhythm during walking or running to match with the natural frequency. This could eventually promote a better gait performance.

1 August 2007 in Renewable Energy
Verified
Journal Article
Closed access
Alireza MaheriAlireza Maheri
Alireza Maheri
SNSiamak Noroozi
Siamak Noroozi
JVJohn Vinney
John Vinney

18 September 2013 in Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology
Verified
Journal Article
Closed access
SNSiamak Noroozi
Siamak Noroozi
ARAbdul Ga Rahman
Abdul Ga Rahman
SKShin Yee Khoo
Shin Yee Khoo
SZSaeed Zahedi
Saeed Zahedi
PSPhilip Sewell
Philip Sewell
ZOZhi Chao Ong
Zhi Chao Ong
In this research, it is proven that perfect synchronisation between the input impulse (human effort) and the ground reaction impulse/impact can result in a phenomenon called the dynamic elastic response to impulse synchronisation with favourable consequences to the behaviour of the energy storing and returning foot. An energy storing and returning composite prosthetic foot was first used in elite competition at the 1988 Paralympic Games. Since its introduction, the prostheses have proven to be a source of controversy. In 2008, it was concluded that the athletes who use such technology when running are in an advantageous position when compared to able-bodied athletes. However, these findings have since been disputed. There still remain unanswered questions regarding the level of contribution of energy storing and returning feet in the performance of amputee athletes. A series of investigations have previously been conducted to study the dynamic characteristics of a number of energy storing and returning composite prosthetic feet. It was found that if a sinusoidal input impulse, with a frequency close to one of the energy storing and returning feet’s natural frequencies, could be applied, it can make the energy storing and returning foot susceptible to resonance, which, in the case of bending mode, if sustained can lead to a gain in height or increased velocity.

11 November 2017 in Medical & Biological Engineering & Computing
Verified
Journal Article
Open access
PDF file
NANavid Aslani
Navid Aslani
SNSiamak Noroozi
Siamak Noroozi
PDPhilip Davenport
Philip Davenport
RHRichard Hartley
Richard Hartley
MDMihai Dupac
Mihai Dupac
PSPhilip Sewell
Philip Sewell
Traditional shoulder range of movement (ROM) measurement tools suffer from inaccuracy or from long experimental setup times. Recently, it has been demonstrated that relatively low-cost wearable inertial measurement unit (IMU) sensors can overcome many of the limitations of traditional motion tracking systems. The aim of this study is to develop and evaluate a single IMU combined with an electromyography (EMG) sensor to monitor the 3D reachable workspace with simultaneous measurement of deltoid muscle activity across the shoulder ROM. Six volunteer subjects with healthy shoulders and one participant with a ‘frozen’ shoulder were recruited to the study. Arm movement in 3D space was plotted in spherical coordinates while the relative EMG intensity of any arm position is presented graphically. The results showed that there was an average ROM surface area of 27291 ± 538 deg2 among all six healthy individuals and a ROM surface area of 13571 ± 308 deg2 for the subject with frozen shoulder. All three sections of the deltoid show greater EMG activity at higher elevation angles. Using such tools enables individuals, surgeons and physiotherapists to measure the maximum envelope of motion in conjunction with muscle activity in order to provide an objective assessment of shoulder performance in the voluntary 3D workspace.

11 April 2016 in Sports Engineering
Verified
Journal Article
Open access
PDF file
NANavid Aslani
Navid Aslani
SNSiamak Noroozi
Siamak Noroozi
SKShin Yee Khoo
Shin Yee Khoo
ZOZhi Chao Ong
Zhi Chao Ong
CMChristine Maggs
Christine Maggs
Efficient walking or running requires symmetrical gait. Gait symmetry is one of the key factors in efficient human dynamics, kinematics and kinetics. The desire of individuals with a lower-limb amputation to participate in sports has resulted in the development of energy-storing-and-returning (ESR) feet. This paper analyses a case study to show the effect of symmetry and asymmetry as well as energy transfer efficiency during periodic jumping between simulated bilateral and unilateral runners. A custom gait analysis system is developed as part of this project to track the motion of the body of a physically active subject during a set of predefined motions. Stance and aerial times are accurately measured using a high speed camera. Gait frequency, the level of symmetry and the non-uniform displacement between left and right foot and their effects on the position of the Centre of Mass (CM) were used as criteria to calculate both peak energies and transformation efficiency. Gait asymmetry and discrepancy of energy transfer efficiency between the intact foot and the ESR are observed. It is concluded that unilateral runners require excessive effort to compensate for lack of symmetry as well as asymmetry in energy transfer, causing fatigue which could be a reason why bilateral amputee runners using ESR feet have a superior advantage over unilateral amputees.