Jorma Tapani Järnstedt

Dr. Jorma Tapani Järnstedt


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2022 in Oral Radiology
Verified
Journal Article
Open access
PDF file
JHJaakko Heikkinen
Jaakko Heikkinen
VJViljami Jokihaka
Viljami Jokihaka
JNJanne Nurminen
Janne Nurminen
VJVille Jussila
Ville Jussila
JVJarno Velhonoja
Jarno Velhonoja
JHJussi Hirvonen
Jussi Hirvonen
Objectives: To determine the diagnostic accuracy of emergency magnetic resonance imaging (MRI) in odontogenic maxillofacial infections, the clinical and surgical significance of MRI findings, and whether MRI can identify the tooth responsible for the infection. Methods: A retrospective cohort study reviewed 106 emergency neck MRI scans of patients with neck infections of odontogenic origin. The diagnostic accuracy of MRI in identifying abscesses was studied relative to surgical findings. Correlations were analyzed between various MRI findings and clinical results and outcomes, such as the surgical approach (intraoral vs. extraoral). The ability of MRI findings to predict the causative tooth was assessed in a blinded multi-reader setting. Results: Of the 106 patients with odontogenic infections, 77 (73%) had one or more abscesses. Imaging showed a sensitivity, specificity, and accuracy of 0.95, 0.84, and 0.92, respectively, for MRI diagnosis of an odontogenic abscess. Among the imaging findings, mediastinal edema was the strongest predictor of extraoral surgery. MRI showed bone marrow edema in the majority of patients, and multi-reader assessment showed good reliability. MRI was also able to predict the causative tooth accurately. Conclusions: Emergency neck MRI can accurately detect odontogenic abscesses and reliably point to the causative tooth. These results can increase the utility and reliance on emergency MRI in clinical decision-making.

29 August 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JJJorma Tapani Järnstedt
Jorma Tapani Järnstedt
JSJaakko Sahlsten
Jaakko Sahlsten
JJJoel Jaskari
Joel Jaskari
Kimmo KaskiKimmo Kaski
Kimmo Kaski
HMHelena Mehtonen
Helena Mehtonen
SNSakarat Nalampang
Sakarat Nalampang
Preoperative radiological identification of mandibular canals is essential for maxillofacial surgery. This study demonstrates the reproducibility of a deep learning system (DLS) by evaluating its localisation performance on 165 heterogeneous cone beam computed tomography (CBCT) scans from 72 patients in comparison to an experienced radiologist’s annotations. We evaluated the performance of the DLS using the symmetric mean curve distance (SMCD), the average symmetric surface distance (ASSD), and the Dice similarity coefficient (DSC). The reproducibility of the SMCD was assessed using the within-subject coefficient of repeatability (RC). Three other experts rated the diagnostic validity twice using a 0–4 Likert scale. The reproducibility of the Likert scoring was assessed using the repeatability measure (RM). The RC of SMCD was 0.969 mm, the median (interquartile range) SMCD and ASSD were 0.643 (0.186) mm and 0.351 (0.135) mm, respectively, and the mean (standard deviation) DSC was 0.548 (0.138). The DLS performance was most affected by postoperative changes. The RM of the Likert scoring was 0.923 for the radiologist and 0.877 for the DLS. The mean (standard deviation) Likert score was 3.94 (0.27) for the radiologist and 3.84 (0.65) for the DLS. The DLS demonstrated proficient qualitative and quantitative reproducibility, temporal generalisability, and clinical validity.

25 January 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Jari KangasJari Kangas
Jari Kangas
JJJorma Tapani Järnstedt
Jorma Tapani Järnstedt
KRKimmo Ronkainen
Kimmo Ronkainen
JMJohn Mäkelä
John Mäkelä
HMHelena Mehtonen
Helena Mehtonen
RRRoope Raisamo
Roope Raisamo
Three-dimensional (3D) medical images are used for diagnosis and in surgical operation planning. Computer-assisted surgical simulations (CASS) are essential for complex surgical procedures that are often performed in an interdisciplinary manner. Traditionally, the participants study the designs on the same display. In 3D virtual reality (VR) environments, the planner is wearing a head-mounted display (HMD). The designs can be then examined in VR by other persons wearing HMDs, which is a practical use case for the medical metaverse. A multi-user VR environment was built for the planning of an orthognathic–surgical (correction of facial skeleton) operation. Four domain experts (oral and maxillofacial radiologists) experimented with the pilot system and found it useful. It enabled easier observation of the model and a better understanding of the structures. There was a voice connection and co-operation during the procedure was natural. The planning task is complex, leading to a certain level of complexity in the user interface.

16 September 2022 in European Archives of Oto-Rhino-Laryngology
Verified
Journal Article
Open access
PDF file
PTPekka Tamminen
Pekka Tamminen
JJJorma Tapani Järnstedt
Jorma Tapani Järnstedt
ALAntti Lehtinen
Antti Lehtinen
JNJura Numminen
Jura Numminen
LLLauri Lehtimäki
Lauri Lehtimäki
IKIlkka Kivekäs
Ilkka Kivekäs
Purpose: This study will evaluate the clinical quality and usability of peripheral image data from the temporal bone area obtained using a sinonasal ultra-low-dose (ULD) cone-beam computed tomography (CBCT) scan and compare them to those obtained using a high-resolution (HR) CBCT. Methods: The population consisted of 66 anatomical sites (ears of 33 subjects) imaged using two modalities: an HR CBCT (Scanora 3Dx scanner; Soredex, Tuusula, Finland) and a ULD CBCT (Promax 3D Mid scanner; Plandent, Helsinki, Finland). The image quality (IQ) for every anatomical site in each image was rated using a Likert scale from 0 to 5. Results: The quality of ULD CBCT scans was clinically sufficient in over 95% of the assessed images of the sigmoid sinus, jugular bulb, epitympanum and mastoid antrum as well as external acoustic meatus (all p > 0.05 compared to HR CBCT). The IQ was clinically sufficient in 75–94% of the assessed images of the scutum, mastoid segment of the facial nerve, cochlea and semicircular canals (all p < 0.05 compared to HR CBCT). The overall IQ of the HR CBCT scans was good or excellent. Conclusion: CBCT imaging and the data at image margins are underutilized. CBCT can produce excellent structural resolution with conventional imaging parameters, even with off-focus images. Using ultra-low doses of radiation, the produced IQ is clinically sufficient. We encourage ear surgeons to check the patients’ imaging history and to consider the use of imaging modalities that involve lower radiation doses especially when conducting repetitive investigations and with children.

18 August 2025 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
LOLotta Orsmaa
Lotta Orsmaa
MSMikko Saukkoriipi
Mikko Saukkoriipi
Jari KangasJari Kangas
Jari Kangas
NRNastaran Rasouli
Nastaran Rasouli
JJJorma Tapani Järnstedt
Jorma Tapani Järnstedt
RRRoope Raisamo
Roope Raisamo
Purpose:: Artificial intelligence (AI) achieves high-quality annotations of radiological images, yet often lacks the robustness required in clinical practice. Interactive annotation starts with an AI-generated delineation, allowing radiologists to refine it with feedback, potentially improving precision and reliability. These techniques have been explored in two-dimensional desktop environments, but are not validated by radiologists or integrated with immersive visualization technologies. We used a Virtual Reality (VR) system to determine whether (1) the annotation quality improves when radiologists can edit the AI annotation and (2) whether the extra work done by editing is worthwhile. Methods:: We evaluated the clinical feasibility of an interactive VR approach to annotate mandibular and mental foramina on segmented 3D mandibular models. Three experienced dentomaxillofacial radiologists reviewed AI-generated annotations and, when needed, refined them at the voxel level in 3D space through click-based interactions until clinical standards were met. Results:: Our results indicate that integrating expert feedback within an immersive VR environment enhances annotation accuracy, improves clinical usability, and offers valuable insights for developing medical image analysis systems incorporating radiologist input. Conclusion:: This study is the first to compare the quality of original and interactive AI annotation and to use radiologists’ opinions as the measure. More research is needed for generalization.

2 December 2023
Verified
Conference Paper
Open access
HMHelena Mehtonen
Helena Mehtonen
JJJorma Tapani Järnstedt
Jorma Tapani Järnstedt
Jari KangasJari Kangas
Jari Kangas
SKSriram Kumar
Sriram Kumar
IRIrina Rinta-Kiikka
Irina Rinta-Kiikka
RRRoope Raisamo
Roope Raisamo
Although there are promising results from the use of virtual reality (VR) in the craniomaxillofacial field, there is still a need to validate the usability and properties of the VR environment and interaction techniques. The aim of this study was to evaluate the suitability of VR interaction methods for craniomaxillofacial computer-assisted surgical simulation (CASS) and to identify possible areas for improvement. Four VR interaction conditions were compared quantitatively and qualitatively: Hand, Mouse, Pen and, Controller. Four oral and maxillofacial radiologists performed a VR marking task on skull stereolithography models. Quantitative measures included accuracy, completion time, number of grasps and development. Qualitative attributes were easiness, efficiency, physical effort, accuracy, and naturalness. Mouse (1,51 mm) and Controller (1,73 mm) were the most accurate, Pen was the close third (2,06 mm), while Hand (4,52 mm) scored poorly. Mouse was slower and more burdensome than the other conditions. The accuracy of Pen and the completion times of Hand, Pen and Mouse improved over time. The usability of Controller (1,50) was rated best in Likert scale (1-5), with Pen (1,75) the close second. Mouse (3,00) and Hand (3,57) were inferior, and overall, Hand was the least preferred. Controller and Mouse achieved acceptable accuracy for craniomaxillofacial CASS. The usability of Controller was also rated highest, and it was the preferred choice of the radiologists. The combination of Mouse and VR was unnatural and cumbersome. To achieve an acceptable level of accuracy for Hand, hand tracking technology needs to be significantly improved.