Evon S Ereifej

Dr. Evon S Ereifej


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2018 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
EEEvon S Ereifej
Evon S Ereifej
GRGriffin M. Rial
Griffin M. Rial
JHJohn K. Hermann
John K. Hermann
CSCara S. Smith
Cara S. Smith
Seth MeadeSeth Meade
Seth Meade
JCJeffrey R. Capadona
Jeffrey R. Capadona
Clinical implantation of intracortical microelectrodes has been hindered, at least in part, by the perpetual inflammatory response occurring after device implantation. The neuroinflammatory response observed after device implantation has been correlated to oxidative stress that occurs due to neurological injury and disease. However, there has yet to be a definitive link of oxidative stress to intracortical microelectrode implantation. Thus, the objective of this study is to give direct evidence of oxidative stress following intracortical microelectrode implantation. This study also aims to identify potential molecular targets to attenuate oxidative stress observed postimplantation. Here, we implanted adult rats with silicon non-functional microelectrode probes for 4 weeks and compared the oxidative stress response to no surgery controls through postmortem gene expression analysis and qualitative histological observation of oxidative stress markers. Gene expression analysis results at 4 weeks postimplantation indicated that EH domain-containing 2, prion protein gene (Prnp), and Stearoyl-Coenzyme A desaturase 1 (Scd1) were all significantly higher for animals implanted with intracortical microelectrode probes compared to no surgery control animals. To the contrary, NADPH oxidase activator 1 (Noxa1) relative gene expression was significantly lower for implanted animals compared to no surgery control animals. Histological observation of oxidative stress showed an increased expression of oxidized proteins, lipids, and nucleic acids concentrated around the implant site. Collectively, our results reveal there is a presence of oxidative stress following intracortical microelectrode implantation compared to no surgery controls. Further investigation targeting these specific oxidative stress linked genes could be beneficial to understanding potential mechanisms and downstream therapeutics that can be utilized to reduce oxidative stress-mediated damage following microelectrode implantation.

17 July 2018 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
YKYoujoung Kim
Youjoung Kim
Seth MeadeSeth Meade
Seth Meade
KCKeying Chen
Keying Chen
HFHe Feng
He Feng
JRJacob Rayyan
Jacob Rayyan
EEEvon S Ereifej
Evon S Ereifej
Intracortical microelectrodes (IME) are neural devices that initially were designed to function as neuroscience tools to enable researchers to understand the nervous system. Over the years, technology that aids interfacing with the nervous system has allowed the ability to treat patients with a wide range of neurological injuries and diseases. Despite the substantial success that has been demonstrated using IME in neural interface applications, these implants eventually fail due to loss of quality recording signals. Recent strategies to improve interfacing with the nervous system have been inspired by methods that mimic the native tissue. This review focusses on one strategy in particular, nano-architecture, a term we introduce that encompasses the approach of roughening the surface of the implant. Various nano-architecture approaches have been hypothesized to improve the biocompatibility of IMEs, enhance the recording quality, and increase the longevity of the implant. This review will begin by introducing IME technology and discuss the challenges facing the clinical deployment of IME technology. The biological inspiration of nano-architecture approaches will be explained as well as leading fabrication methods used to create nano-architecture and their limitations. A review of the effects of nano-architecture surfaces on neural cells will be examined, depicting the various cellular responses to these modified surfaces in both in vitro and pre-clinical models. The proposed mechanism elucidating the ability of nano-architectures to influence cellular phenotype will be considered. Finally, the frontiers of next generation nano-architecture IMEs will be identified, with perspective given on the future impact of this interfacing approach.

4 December 2017 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
EEEvon S Ereifej
Evon S Ereifej
CSCara S. Smith
Cara S. Smith
Seth MeadeSeth Meade
Seth Meade
KCKeying Chen
Keying Chen
HFHe Feng
He Feng
JCJeffrey R. Capadona
Jeffrey R. Capadona

19 January 2020 in Journal of Visualized Experiments
Verified
Journal Article
Closed access
PDF file
SMShreya Mahajan
Shreya Mahajan
JSJonah A. Sharkins
Jonah A. Sharkins
AHAllen H. Hunter
Allen H. Hunter
AAAmir Avishai
Amir Avishai
EEEvon S Ereifej
Evon S Ereifej
With advances in electronics and fabrication technology, intracortical microelectrodes have undergone substantial improvements enabling the production of sophisticated microelectrodes with greater resolution and expanded capabilities. The progress in fabrication technology has supported the development of biomimetic electrodes, which aim to seamlessly integrate into the brain parenchyma, reduce the neuroinflammatory response observed after electrode insertion and improve the quality and longevity of electrophysiological recordings. Here we describe a protocol to employ a biomimetic approach recently classified as nano-architecture. The use of focused ion beam lithography (FIB) was utilized in this protocol to etch specific nano-architecture features into the surface of non-functional and functional single shank intracortical microelectrodes. Etching nano-architectures into the electrode surface indicated possible improvements of biocompatibility and functionality of the implanted device. One of the benefits of using FIB is the ability to etch on manufactured devices, as opposed to during the fabrication of the device, facilitating boundless possibilities to modify numerous medical devices post-manufacturing. The protocol presented herein can be optimized for various material types, nano-architecture features, and types of devices. Augmenting the surface of implanted medical devices can improve the device performance and integration into the tissue.

17 February 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
JDJonathan L. Duncan
Jonathan L. Duncan
JWJaime Wang
Jaime Wang
GGGabriele Glusauskas
Gabriele Glusauskas
GWGwendolyn Weagraff
Gwendolyn Weagraff
YGYue Gao
Yue Gao
JCJeffrey R. Capadona
Jeffrey R. Capadona
(1) Background: Intracortical microelectrodes (IMEs) are an important part of interfacing with the central nervous system (CNS) and recording neural signals. However, recording electrodes have shown a characteristic steady decline in recording performance owing to chronic neuroinflammation. The topography of implanted devices has been explored to mimic the nanoscale three-dimensional architecture of the extracellular matrix. Our previous work used histology to study the implant sites of non-recording probes and showed that a nanoscale topography at the probe surface mitigated the neuroinflammatory response compared to probes with smooth surfaces. Here, we hypothesized that the improvement in the neuroinflammatory response for probes with nanoscale surface topography would extend to improved recording performance. (2) Methods: A novel design modification was implemented on planar silicon-based neural probes by etching nanopatterned grooves (with a 500 nm pitch) into the probe shank. To assess the hypothesis, two groups of rats were implanted with either nanopatterned (n = 6) or smooth control (n = 6) probes, and their recording performance was evaluated over 4 weeks. Postmortem gene expression analysis was performed to compare the neuroinflammatory response from the two groups. (3) Results: Nanopatterned probes demonstrated an increased impedance and noise floor compared to controls. However, the recording performances of the nanopatterned and smooth probes were similar, with active electrode yields for control probes and nanopatterned probes being approximately 50% and 45%, respectively, by 4 weeks post-implantation. Gene expression analysis showed one gene, Sirt1, differentially expressed out of 152 in the panel. (4) Conclusions: this study provides a foundation for investigating novel nanoscale topographies on neural probes.

16 January 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
JDJonathan Duncan
Jonathan Duncan
JWJaime Wang
Jaime Wang
GGGabriele Glusauskas
Gabriele Glusauskas
GWGwendolyn Weagraff
Gwendolyn Weagraff
YGYue Gao
Yue Gao
JCJeffrey R. Capadona
Jeffrey R. Capadona
(1) Background: Intracortical microelectrodes (IMEs) are an important part of interfacing with the central nervous system (CNS) and recording neural signals. However, recording electrodes have shown a characteristic steady decline in recording performance owing to chronic neuroinflammation. The topography of implanted devices has been explored to mimic the nanoscale three-dimensional architecture of the extracellular matrix. Our previous work used histology to study the implant sites of non-recording probes and showed that a nanoscale topography at the probe surface mitigated the neuroinflammatory response compared to probes with smooth surfaces. Here, we hypothesized that the improvement in the neuroinflammatory response for probes with nanoscale surface topography would extend to improved recording performance. (2) Methods: A novel design modification was implemented on planar silicon-based neural probes by etching nanopatterned grooves (with a 500 nm pitch) into the probe shank. To assess the hypothesis, two groups of rats were implanted with either nanopatterned (n=6) or smooth control (n=6) probes, and their recording performance was assessed over 4 weeks. Postmortem gene expression analysis was performed to compare the neuroinflammatory response from the two groups. (3) Results: Nanopatterned probes demonstrated increased impedance and noise floor compared to controls. However, the recording performance of the nanopatterned and smooth probes was similar, with active electrode yield for control probes and nanopatterned probes being approximately 50% and 45%, respectively by 4 weeks post-implantation. Gene expression analysis showed 1 gene, Sirt1, differentially expressed out of 152 in the panel. (4) Conclusions: This study provides a foundation for investigating novel nanoscale topographies on neural probes.