Xiangliang Xu

Prof. Dr. Xiangliang Xu


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2017 in Medical Engineering & Physics
Verified
Journal Article
Closed access
XXXiangliang Xu
Xiangliang Xu
DLDanmei Luo
Danmei Luo
CGChuan-bin Guo
Chuan-bin Guo
Qiguo RongQiguo Rong
Qiguo Rong
A novel and custom-made selective laser melting (SLM) 3D-printed alloplastic temporomandibular joint (TMJ) prosthesis is proposed. The titanium-6aluminium-4vanadium (Ti-6Al-4V) condyle component and ultra-high molecular weight polyethylene (UHMWPE) fossa component comprised the total alloplastic TMJ replacement prosthesis. For the condyle component, an optimized tetrahedral open-porous scaffold with combined connection structures, i.e. an inlay rod and an onlay plate, between the prosthesis and remaining mandible was designed. The trajectory of movement of the intact condyle was assessed via kinematic analysis to facilitate the design of the fossa component. The behaviours of the intact mandible and mandible with the prosthesis were compared. The biomechanical behaviour was analysed by assessing the stress distribution on the prosthesis and strain distribution on the mandible. After muscle force was applied, the magnitude of the compressive strain on the condyle neck of the mandible with the prosthesis was lower than that on the condyle neck of the intact mandible, with the exception of the area about the screws; additionally, the magnitude of the strain at the scaffold-bone interface was relatively high.

11 December 2017 in BioMed Research International
Verified
Journal Article
Open access
PDF file
XXXiangliang Xu
Xiangliang Xu
SZShijie Zhao
Shijie Zhao
HLHui Liu
Hui Liu
ZSZhipeng Sun
Zhipeng Sun
JWJianwei Wang
Jianwei Wang
WZWeiguang Zhang
Weiguang Zhang
Objective. To obtain anatomical data of maxillary-zygomatic complex based on simulating the zygomatic implantation using cadaver heads and three-dimensional computerized tomography (3D-CT). Methods. Simulating zygomatic implantation was performed using seven cadaver heads and 3D-CT images from forty-eight adults. After measuring the maxillary-zygomatic complex, we analyzed the position between the implantation path and the maxillary sinus cavity as well as the distance between the implantation path and the zygomatic nerve. Results. The distance from the starting point to the endpoint of the implant was 56.85 ± 5.35 mm in cadaver heads and 58.15 ± 7.37 mm in 3D-CT images. For the most common implantation path (80.20%), the implant went through the maxillary sinus cavity completely. The projecting points of the implant axis (IA) on the surface of zygoma were mainly located in the region of frontal process of zygomatic bone close to the lateral orbital wall. The distances between IA and zygomatic nerve in 53 sides were shorter than 2 mm. Conclusion. The simulating zygomatic implantation on cadaver skulls and 3D-CT imaging provided useful anatomical data of the maxillary-zygomatic complex. It is necessary to take care to avoid the zygomatic nerve injury during implantation, because it frequently appears on the route of implantation.

7 March 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
KCKenan Chen
Kenan Chen
YCYoubai Chen
Youbai Chen
PCPeng Chen
Peng Chen
JJJunqi Jiang
Junqi Jiang
EWEnbo Wang
Enbo Wang
XXXiangliang Xu
Xiangliang Xu
This study aims to evaluate the accuracy of cone beam computed tomography (CBCT) in predicting the exposure of inferior alveolar nerve (IAN) during complicated mandibular third molars (M3M) extraction. 115 M3Ms with canal cortical defect signs on preoperative CBCT were extracted. Candidate variables included sex, age, types of CBCT machine, the Winter classification of M3Ms, the size of root entering the canal on CBCT, the size of cortical defect on CBCT. The primary outcome was the exposure of IAN and the exposed neurovascular bundle size which was recorded measured under endoscope. The independent sample t-test, Bland-Altman analysis was performed to assess the agreement between the CBCT and endoscopic measurements. The regression analysis was performed to determine if there was a correlation between the measurements of CBCT and endoscope. The Chi-square test was used to evaluate whether the proportion of IAN exposure in different impacted M3M types were consistent. ANOVA was used to test the correlation between the actual size of exposed IAN and (1) Winter classification types; (2) types of CBCT machine. 85/115 (73.9%) M3Ms with canal cortical defect signs on preoperative CBCT had intraoperative exposure of IAN. The average length and width of the exposed IAN were 5.89 ± 1.72 mm and 2.48 ± 0.79 mm, which were significantly smaller than the size of root entering the canal on CBCT (9.69 ± 3.05 mm and 3.26 ± 0.87 mm, P < 0.001) but larger than the cortical defect size (5.06 ± 2.05 mm and 2.10 ± 0.54 mm, P < 0.05). The regression analysis showed that IAN exposure was significantly associated with the cortical defect length (0.1 mm) on CBCT (OR = 1.38, P = 0.001). The probability of intraoperative IAN exposure was statistically different among different Winter classifications of M3M and the probability of IAN exposure was higher in non-horizontal impacted type according to Chi-square test results. ANOVA showed statistical difference between exposed IAN length and Winter classification types (p = 0.001). Not all M3Ms with tooth-IAN contact signs on preoperative CBCT indicated intraoperative IAN exposure. The size of root entering the canal on CBCT were mostly larger than the intraoperative endoscopic measurements. IAN exposure can be accurately predicted by the length of cortical defect on CBCT. Non-horizontal impaction predisposed the M3M to a higher risk of intraoperative IAN exposure. Endoscope provides the possibility to observe and record the IAN exposure directly. IAN exposure can be accurately predicted by the length of cortical defect instead of the size of root entering the canal on CBCT. Non-horizontal impaction predisposed the M3M to a higher risk of intraoperative IAN exposure. Not applicable

31 October 2023 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
JWJun-Lin Wang
Jun-Lin Wang
JWJing Wang
Jing Wang
KCKe-Nan Chen
Ke-Nan Chen
JGJian-Qiao Guo
Jian-Qiao Guo
XXXiangliang Xu
Xiangliang Xu
CGChuan-Bin Guo
Chuan-Bin Guo
Objective: This study presents an innovative articular fossa prosthesis generated by the envelope surface of condyle movement, and compares its mandible movements, muscle activities, and joint reaction forces with two temporomandibular joint (TMJ) prostheses using multibody musculoskeletal simulation.Methods: A healthy 23-year-old female was recruited for this study. Cone-beam computed tomographic (CBCT) was performed to reconstruct the mandibular bone geometry. A customized TMJ fossa prosthesis was designed based on the subject-specific envelope surface of condyle movement (ESCM). Mandibular kinematics and jaw-closing muscle electromyography (EMG) were simultaneously recorded during maximum jaw opening-closing movements. To validate our prosthesis design, a mandibular musculoskeletal model was established using flexible multibody dynamics and the obtained kinematics and EMG data. The Biomet fossa prosthesis and the ellipsoidal fossa prosthesis designed by imitating the lower limb prostheses were used for comparison. Simulations were performed to analyze the effects of different fossa prostheses on jaw opening-closing motions, mandibular muscle activation, and contact forces.Results: The maximum opening displacement for the envelope-based fossa prosthesis was greater than those for Biomet and ellipsoidal prostheses (36 mm, 35 mm, and 33 mm, respectively). The mandibular musculoskeletal model with ellipsoidal prosthesis led to dislocation near maximal jaw opening. Compared to Biomet, the envelope-based fossa reduced the digastric and lateral pterygoid activation at maximal jaw opening. It also reduced the maximal resistance to condylar sliding on the intact side by 63.2 N.Conclusion: A customized TMJ fossa prosthesis was successfully developed using the ESCM concept. Our study of musculoskeletal multibody modeling has highlighted its advantages and potential. The artificial fossa design successfully achieved a wider condylar range of motion. It also reduced the activation of jaw opening muscles on the affected side and resistance on the intact side. This study showed that an ESCM-based approach may be useful for optimizing TMJ fossa prostheses design.

11 February 2023 in Odontology
Verified
Journal Article
Open access
PDF file
JJJun-Qi Jiang
Jun-Qi Jiang
YKYan-Feng Kang
Yan-Feng Kang
KCKe-Nan Chen
Ke-Nan Chen
NCNian-Hui Cui
Nian-Hui Cui
ZYZi-Yu Yan
Zi-Yu Yan
XXXiangliang Xu
Xiangliang Xu
The aim of this study is to assess the relationship between somatosensory functional changes and inferior alveolar nerve (IAN) exposure after impacted mandibular third molars (M3M) removal. We recruited 35 patients who underwent impacted M3M extraction near the IAN. The M3Ms were extracted by combined endoscopy, piezosurgery, and contra-angle high-speed turbine handpiece. All IAN canal perforations and exposed regions were recorded and measured by endoscopy after extraction and on cone-beam computed tomography (CBCT) images before extraction. The patients were followed up 1, 7, and 35 days after surgery. A standardized quantitative sensory testing (QST) battery was performed on the lower lip skin. All of 35 cases had exposed IAN on CBCT images, 5 of which had no exposed IAN under endoscopy. For the other 30 cases, the endoscopy-measured IAN length and width were shorter than the CBCT measurements (P < 0.001). The warm and mechanical detection thresholds (MDT) on the operation side were significantly higher than the contralateral side after surgery (P < 0.05). Thermal sensory limen, MDT, and cold pain threshold were strongly correlated with the exposed IAN length and MDT also with the exposed IAN width one day after surgery. In conclusion, it was found that not all exposed IAN in CBCT images were real exposure after surgery. The intraoperative exposed IAN endoscopic measurements were smaller than by CBCT and strongly correlated with some QST parameters.

16 November 2024 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
JWJiayi Wang
Jiayi Wang
BCBo Chen
Bo Chen
YZYuexin Zhao
Yuexin Zhao
SPShaoxia Pan
Shaoxia Pan
XXXiangliang Xu
Xiangliang Xu
To investigate the difference in bone-implant contact (BIC) and the rate of infratemporal fossa intrusion among different apex sites for quad zygomatic implants (ZIs) design in edentulous patients with severe alveolar bone resorption. Patients with maxillary edentulism were evaluated. Alveolar bone resorption was assessed using the Cawood and Howell classification. Participants with Class IV or Class V/VI bone resorption were selected. The zygomatic bone was devided into upper, middle and lower thirds, with four potential implant apex locations identified in each third. Virtual planning for quad ZIs, along with measurements of BIC were performed. Additionally, the occurrence of ZIs intrusion into the infratemporal fossa was examined, and the distance between ZI and orbital cavity was measured. A total of 28 CBCT scans of edentulous patients, encompassing 56 zygomas, were analyzed. Thirty-nine single lateral posterior edentulous jaws were classified into Class IV subgroup, while 17 into Class V/IV subgroup. Among all patients and patients in subgroups, the anterior and posterior ZI exhibited the highest BIC at points A3 and B2, respectively. The average zygomatic BIC at A3 apex point was 18.3 ± 3.9 mm, and that at the B2 apex point was 16.3 ± 5.3 mm. Quad ZIs risk intrusion into the infratemporal fossa when positioned at B2, B3, and at all apex points of the lower zygoma segment. Three anterior ZIs at A3 point show less than 1 mm distance to orbital cavity. Overall, A3 and B1 apex points showed high BIC and low infratemporal intrusion rate for quad ZIs, irrespective of patient’s alveolar bone resorption status. The optional apex point for anterior and posterior quad ZIs is A3 and B1, respectively, regardless of the patients’s alveolar bone resorption level. Alveolar bone resorption does not affect the BIC for quad ZIs. Anterior ZI positioned at A3 point may present high risk for orbital penetration and may not be reccomended in a Quad ZI approach. The clinical research is registered under the number ChiCTR2100044472.