The purpose of this study was to reveal the structural properties that need to be considered in dental implant treatment by investigating differences between dentulous and edentulous maxillae in the three-dimensional (3D) microstructure of the incisive canals (ICs) and their surrounding bone. A total of 40 maxillary bones comprising 20 dentulous maxillae and 20 edentulous maxillae were imaged by micro-CT for 3D observation and measurement of the IC and alveolar bone in the anterior region of the IC. The Y-morphology canal was most frequently observed at 60% in dentulous maxilla and 55% in edentulous maxilla. There was a significant difference between dentulous and edentulous maxillae in IC diameter and volume, but no significant difference between the two in the major axis of the ICs. The anatomic structure surrounding the IC has limited area for implant placement. Therefore, where esthetic and long-term maintenance requirements are taken into account, careful attention is needed when setting the placement position. Also, due to the resorption of bone, edentulous maxillae have a different IC morphology from dentulous maxillae, and therefore, a cautious approach is required.
19 March 2020 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
This study aimed to investigate the release of metallic ions from cobalt–chromium (Co-Cr) alloys fabricated by additive manufacturing (AM) for comparison with dental casting. Co-Cr alloys were fabricated via AM using selective laser melting (SLM) and electron beam melting (EBM) in powder-bed fusion. Polished and mechanically ground specimens were prepared. Each specimen was analyzed using an electron probe microanalyzer (EPMA). Each specimen was immersed in an acidic saline solution for 7 days in accordance with ISO 10271: 2020. The EPMA indicated the segregation of some elements in the as-prepared SLM and EBM specimens, whereas the polished and ground specimens exhibited a homogenous elemental distribution. The total amount of ion release from the SLM and EBM specimens was confirmed to be less than 7 μg/cm2, which was less than 42 μg/cm2 for the cast specimen. The polished and ground specimens exhibited an even lower ion release than the as-prepared specimens. The amount of ions released from the Co-Cr alloy was less than the 200 μg/cm² requirement of ISO 22674: 2022. Co-Cr alloys fabricated by SLM and EBM could provide superior corrosion resistance to cast specimens. AM could be a valuable method for fabricating appliances and denture frameworks in dentistry.
This study investigated the effects of mechanical and chemical pretreatment of polyetherketoneketone (PEKK) on shear bond strength (SBS) to root dentin using two types of resin cement. A total of 100 PEKK specimens were prepared and polished. Sixty specimens were mechanically treated by sandblasting (50-µm Al2O3 for 10 s at 0.2-0.25 MPa), and the remaining 40 were untreated. Self-adhesive resin cement and conventional resin cement were used. PEKK specimens bonded to root dentin using self-adhesive resin cement were classified into three groups by pretreatment method: (1) untreated PEKK, (2) mechanical pretreatment (sandblasted PEKK), and (3) both mechanical and chemical pretreatment (PEKK sandblasting as well as application of Scotchbond Universal; 3M Oral Care). Conventional resin cement was pretreated following the same steps (1-3) as those followed for self-adhesive specimens. Each group included 10 specimens. PEKK specimens after surface treatments were examined using SEM. SBS tests were performed using a universal testing machine, and data were statistically analyzed using one-way ANOVA and Tukey's multiple comparison test (p < 0.05). No significant difference was observed between cements with and without sandblasting. However, self-adhesive specimens with both mechanical and chemical pretreatments demonstrated higher SBS than other cements with or without pretreatment. Mechanical pretreatment by sandblasting did not improve the PEKK-root dentin SBS. However, combined mechanical (sandblasting) and chemical pretreatment (ScotchBond Universal) significantly improved the SBS between the PEKK and root dentin.
The wear of enamel and crown restorative materials often occur by occlusion. The purpose of this study was to evaluate the wear volume between glass-ceramics used for CAD/CAM blocks (lithium disilicate: Initial LiSi block (LIS), IPS e.max CAD (IPS), zirconia-reinforced lithium silicate glass-ceramics: Celtra DUO (DUO), VITA Suprinity (VITS) and feldspar-based glass-ceramics: Vitablocs Mark II (MAK)) and bovine tooth enamel using a two-body wear test, the hardness, three-point bending strength, micro-structure and the element components of glass-ceramics. The data were analyzed using a one-way analysis of variance and Tukey’s multiple comparison test (α = 0.05). IPS and DUO with relatively large size crystal gain had significantly larger abrader wear volumes. Zirconia-reinforced lithium silicate glass-ceramics (DUO, VITS) caused significantly greater wear volume in antagonist enamel. MAK with scale-shape crystals grains produced distinct scratches after wear tests, both in the material itself and in the enamel. A strong correlation between the mechanical properties (hardness, three-point bending strength) and wear volume could not be confirmed. The type of glass-ceramic, size, and shape of the crystal grains affected the wear behavior of the glass-ceramics for CAD/CAM blocks. Therefore, dentists should consider that wear behavior varies with crystal structure, size, and shape in glass-ceramics for CAD/CAM blocks.
The hyoid is the only bone in the human body that is completely independent, not forming a joint with any other bone; its position is maintained by the suprahyoid and infrahyoid muscles, as well as several ligaments. The purpose of this study was to ascertain the effect of the functional pressure arising from these muscles and ligaments on the hyoid body structure from its bone mineral density, bone quality, and histological observations. The area between the mesial-most part of each lesser horn and the center of the hyoid body was divided equally into four measurement regions. We conducted histological investigations at each measurement region and observed the entheses. To analyze bone mass and bone quality, we also measured bone mineral density (BMD) and analyzed biological apatite (BAp) crystallite orientation in the same regions. Histological observations identified periosteal insertions and fibrocartilaginous entheses. There was no significant difference in BMD between any of the measurement regions, but the preferential orientation of BAp crystallites was stronger in the infrahyoid muscles and ligaments, where fibrocartilaginous entheses are found, than in other places. This suggests that the functional pressure at these sites might exert a major effect not only on the morphological characteristics of the entheses but also on bone quality.