Vicente Leonardo Paucar

Dr. Vicente Leonardo Paucar

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2002 in Electric Power Systems Research
Verified
Journal Article
Closed access
VPVicente Leonardo Paucar
Vicente Leonardo Paucar
MRMarcos J. Rider
Marcos J. Rider

1 January 2004 in IEE Proceedings - Generation, Transmission and Distribution
Verified
Journal Article
Closed access
MRMarcos J. Rider
Marcos J. Rider
VPVicente Leonardo Paucar
Vicente Leonardo Paucar

21 February 2013 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
RARodrigo J. Albuquerque
Rodrigo J. Albuquerque
VPVicente Leonardo Paucar
Vicente Leonardo Paucar
Phasor measurement units (PMUs) equipped with global positioning system (GPS) receivers are the first devices capable of efficiently performing real-time monitoring of remote electrical power systems. Reliability of the monitoring system that exclusively uses PMUs is directly related to the reliability of each unit allocated on the system. As the failure of measurement channels is more common than PMU's failure, a probabilistic evaluation method of the PMUs measurement channels availability for electrical network observability analysis is proposed. In this method, the Markov process is adopted for estimating the measurement channels availability, as well as for determining an equivalent of the state space diagram of all possible operation states of channels for each unit. With the objective to assess the impact of the failure of measurement channels in the observability and reliability of the system, an algorithm that determines the optimal placement of PMUs using a modified binary search, the measurement channels availability for each unit, the global measurement availability, and the critical measurement channels for power system observability analysis was developed. Numerical results using the IEEE 14-bus, IEEE 30-bus, New England 39-bus, and IEEE 118-bus test systems are presented and discussed.

1 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ISInocêncio Santos
Inocêncio Santos
CCChristian Diniz Carvalho
Christian Diniz Carvalho
GFGilberto Balby Araujo Filho
Gilberto Balby Araujo Filho
CACassio Daniel Salomão Silva Andrade
Cassio Daniel Salomão Silva Andrade
GSGiselle Cutrim de Oliveira Santos
Giselle Cutrim de Oliveira Santos
FSFrancisco Sávio Mendes Sinfrônio
Francisco Sávio Mendes Sinfrônio
Non-standard diesel blends can be harmful to the environment and human health. In this context, a simple analytical method to estimate the biodiesel mixture ratio in diesel was developed based on impedance spectroscopy (IS) associated with interdigitated sensors. In this article, four different interdigitated sensors with varied comb spacing (G) were simulated using the COMSOL Multiphysics software. Based on finite element simulations, four interdigitated electrode architectures were manufactured and evaluated. The best geometry was chosen according to theoretical data simulations, and its interdigitated electrodes were manufactured for the compositional evaluation of pseudo-binary biodiesel–diesel mixtures. According to the X-ray powder diffraction technique, the deposition of the conductive layer (Au0) over the surface of the dielectric substrate (SiO2) did not alter its phase composition. In the analysis of AFM and SEM, it was possible to observe irregular edges on the electrodes, possibly related to the manufacturing process of the thin layers and mechanical stability. Another characteristic observed in the AFM images was the height of the step of the gold layer of the sensor. Several cross sections were obtained, and the mean step value was 225.71 ± 0.0032 nm. Although there were differences in the roughness, the whole sensor had nanometric roughness. Based on the finite element method simulation performed, it can be assumed that the geometric parameters more suitable for the manufacturing of the electrode are W = 20 µm, L = 1000 µm, G = 50 µm, and N = 40 digits. The electrical characterization performed by impedance spectroscopy showed that we could differentiate between biodiesel and diesel fuels and their pseudo-binary mixtures in the low-frequency region.

13 November 2002
Verified
Conference Paper
Closed access
VPVicente Leonardo Paucar
Vicente Leonardo Paucar
MRMarcos J. Rider
Marcos J. Rider
In this paper, a flexible formulation about the pricing of active and reactive power is presented. This proposal is developed using a decoupled formulation identifying the active and reactive subproblems. A model for the price calculation of the reactive power which is intended to incentive the participation of agents of the electricity markets is analyzed. An optimal power flow (OPF) to solve the reactive power subproblem which considers the production costs of the reactive power and the active losses minimization in the objective function, has been implemented. In order to solve the OPF and consequently obtaining the active and reactive power marginal cost prices has been adopted a nonlinear programming methodology. Tests using a 9-bus system for several load conditions show the validity of the methodology.