In the context of global climate change, the implementation of building energy conservation and carbon reduction, as well as the realization of zero-energy buildings, is a key measure to cope with climate change and resource depletion. A substation is an indispensable building in the process of urbanization construction. However, in existing cold areas, the heating form of substations generally adopts electric heating, which consumes a large amount of energy. This paper optimizes the existing HVAC form of substations through the rational utilization of surrounding environmental resources and puts forward reasonable building energy-saving and carbon-reduction methods. It demonstrates the feasibility of combining solar photovoltaic power generation systems, air source heat pumps, and natural ventilation to optimize energy savings and carbon reduction in the main control building of a substation in a cold area. The computational fluid dynamics (CFD) method is used to demonstrate the feasibility of natural ventilation during the summer and transition seasons. The data indicate that the installation of a solar photovoltaic power generation system results in an average annual power generation of 18.75 MWh. Additionally, using an air source heat pump can save 44.5% of electricity compared to electric heating. When both a solar photovoltaic power generation system and an air source heat pump are used to provide a building with cold and heat sources, the annual emissions of CO2 can be reduced by 4.90 tons compared to a traditional electric heating system.
14 October 2022 in Journal of Thermal Science and Engineering Applications
CO2 is a promising refrigerant substitute, and falling film evaporator is widely used in high-capacity heat pump systems. In this article, a CO2 heat pump experimental device is built. According to experimental parameters, a CO2 falling film heat exchanger is fabricated. The falling film heat exchanger is used in heat pump evaporator, and its heat transfer characteristics are analyzed and tested. The outer diameter of the heat exchanger is 219 mm, outer diameter of the inner tube is 15.88 mm, and total outer surface area of the inner tube is 0.58 m2. Number of internal tubes was 12, each with a length of 0.97 m. During the test, change of heat transfer coefficient of each tube was analyzed when evaporation temperature, CO2 mass flowrate, and heat flow density changed. The influence of the position of heat exchange tube inside falling film evaporator on heat transfer coefficient is analyzed. The order of heat transfer coefficient of internal heat exchange tube is obtained. Finally, database of CO2 falling film evaporator is established. Through data sorting, heat exchange correlation formula is obtained. The deviation of 90% data in database is less than 5%. Heat exchange correlation formula has good accuracy.
23 May 2024 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects