Hiroaki Kumada

Prof. Hiroaki Kumada

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2014 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
HKHiroaki Kumada
Hiroaki Kumada
AMA. Matsumura
A. Matsumura
HSH. Sakurai
H. Sakurai
TST. Sakae
T. Sakae
MYM. Yoshioka
M. Yoshioka
HNH. Nakashima
H. Nakashima

5 October 2023 in EPJ Techniques and Instrumentation
Verified
Journal Article
Open access
PDF file
HKHiroaki Kumada
Hiroaki Kumada
TSTakeji Sakae
Takeji Sakae
HSHideyuki Sakurai
Hideyuki Sakurai
Recently, progress in technology for accelerator-based neutron sources has increased attention regarding boron neutron capture therapy (BNCT). BNCT is a type of radiotherapy that combines neutrons and boron drugs and is expected to be used in the treatment of refractory and recurrent cancers. Owing to the need for high-intensity neutrons in treatment, compact accelerator-based neutron sources applicable to BNCT are being developed worldwide. These current projects utilize cyclotrons, linear accelerators, and electrostatic accelerators as accelerators for BNCT devices. Beryllium and lithium are the main target materials for neutron generation. The accelerators for BNCT device are required to accelerate charged particles with an average current ranging from a few milliamperes to a few tens of milliamperes in order to generate neutrons of sufficient intensity for the treatment. Moreover, the target systems require technologies and mechanisms that can withstand the large heat load produced by high-power beam irradiation and prevent blistering. This review outlines and explains the accelerator neutron sources for BNCT and the requirements for the components of each device, such as the accelerator, target material, and beam shaping assembly. In addition, various development projects for accelerator-based BNCT devices worldwide are introduced.

1 December 2015 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
HKHiroaki Kumada
Hiroaki Kumada
TKToshikazu Kurihara
Toshikazu Kurihara
MYMasakazu Yoshioka
Masakazu Yoshioka
HKHitoshi Kobayashi
Hitoshi Kobayashi
HMHiroshi Matsumoto
Hiroshi Matsumoto
AMAkira Matsumura
Akira Matsumura

1 January 2018 in Therapeutic Radiology and Oncology
Verified
Journal Article
Closed access
PDF file
HKHiroaki Kumada
Hiroaki Kumada
KTKenta Takada
Kenta Takada
To perform boron neutron capture therapy (BNCT), a type of radiotherapy, a neutron source as a treatment device and peripheral devices such as a treatment planning system (TPS), patient setting device, and neutron monitor are needed. In particular, a TPS is indispensable software in radiotherapy and enables the simulation of a treatment with neutron beam irradiation with a patient’s three-dimensional model based on the patient’s medical images. In addition, the system supports the determination of suitable irradiation conditions for each patient. The patient setting device works to realize the irradiation conditions determined during treatment planning in the actual irradiation room just before irradiation.

29 January 2012 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
THTakayuki Hashimoto
Takayuki Hashimoto
TITomonori Isobe
Tomonori Isobe
HHHaruko Hashii
Haruko Hashii
HKHiroaki Kumada
Hiroaki Kumada
HTHiroshi Tada
Hiroshi Tada
HSHideyuki Sakurai
Hideyuki Sakurai
Although proton radiotherapy is a promising new approach for cancer patients, functional interference is a concern for patients with implantable cardioverter defibrillators (ICDs). The purpose of this study was to clarify the influence of secondary neutrons induced by proton radiotherapy on ICDs. The experimental set-up simulated proton radiotherapy for a patient with an ICD. Four new ICDs were placed 0.3 cm laterally and 3 cm distally outside the radiation field in order to evaluate the influence of secondary neutrons. The cumulative in-field radiation dose was 107 Gy over 10 sessions of irradiation with a dose rate of 2 Gy/min and a field size of 10 × 10 cm2. After each radiation fraction, interference with the ICD by the therapy was analyzed by an ICD programmer. The dose distributions of secondary neutrons were estimated by Monte-Carlo simulation. The frequency of the power-on reset, the most serious soft error where the programmed pacing mode changes temporarily to a safety back-up mode, was 1 per approximately 50 Gy. The total number of soft errors logged in all devices was 29, which was a rate of 1 soft error per approximately 15 Gy. No permanent device malfunctions were detected. The calculated dose of secondary neutrons per 1 Gy proton dose in the phantom was approximately 1.3-8.9 mSv/Gy. With the present experimental settings, the probability was approximately 1 power-on reset per 50 Gy, which was below the dose level (60-80 Gy) generally used in proton radiotherapy. Further quantitative analysis in various settings is needed to establish guidelines regarding proton radiotherapy for cancer patients with ICDs.

1 November 2020 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
HKHiroaki Kumada
Hiroaki Kumada
KTKenta Takada
Kenta Takada
STSusumu Tanaka
Susumu Tanaka
YMYoshitaka Matsumoto
Yoshitaka Matsumoto
FNFujio Naito
Fujio Naito
TSTakeji Sakae
Takeji Sakae