Steffen Müller

Steffen Müller


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Pascal VorwerkPascal Vorwerk
Pascal Vorwerk
JKJörg Kelleter
Jörg Kelleter
SMSteffen Müller
Steffen Müller
UKUlrich Krause
Ulrich Krause
Effective early fire detection is crucial for preventing damage to people and buildings, especially in fire-prone historic structures. However, due to the infrequent occurrence of fire events throughout a building’s lifespan, real-world data for training models are often sparse. In this study, we applied feature representation transfer and instance transfer in the context of early fire detection using multi-sensor nodes. The goal was to investigate whether training data from a small-scale setup (source domain) can be used to identify various incipient fire scenarios in their early stages within a full-scale test room (target domain). In a first step, we employed Linear Discriminant Analysis (LDA) to create a new feature space solely based on the source domain data and predicted four different fire types (smoldering wood, smoldering cotton, smoldering cable and candle fire) in the target domain with a classification rate up to 69% and a Cohen’s Kappa of 0.58. Notably, lower classification performance was observed for sensor node positions close to the wall in the full-scale test room. In a second experiment, we applied the TrAdaBoost algorithm as a common instance transfer technique to adapt the model to the target domain, assuming that sparse information from the target domain is available. Boosting the data from 1% to 30% was utilized for individual sensor node positions in the target domain to adapt the model to the target domain. We found that additional boosting improved the classification performance (average classification rate of 73% and an average Cohen’s Kappa of 0.63). However, it was noted that excessively boosting the data could lead to overfitting to a specific sensor node position in the target domain, resulting in a reduction in the overall classification performance.

18 August 2023 in Fire
Verified
Journal Article
Open access
PDF file
Pascal VorwerkPascal Vorwerk
Pascal Vorwerk
JKJörg Kelleter
Jörg Kelleter
SMSteffen Müller
Steffen Müller
UKUlrich Krause
Ulrich Krause
This work analyzes a new indoor laboratory dataset looking at early fire indicators in controlled and realistic experiments representing different incipient fire scenarios. The experiments were performed within the constraints of an indoor laboratory setting using multiple distributed sensor nodes in different room positions. Each sensor node collected data of particulate matter (PM), volatile organic compounds (VOCs), carbon monoxide (CO), carbon dioxide (CO2), hydrogen (H2), ultraviolet radiation (UV), air temperature, and humidity in terms of a multivariate time series. These data hold immense value for researchers within the machine learning and data science communities who are keen to explore innovative and advanced statistical and machine learning techniques. They serve as a valuable resource for the development of early fire detection systems. The analysis of the collected data was carried out depending on the Manhattan distance between the fire source and the sensor node. We found that especially larger particles (>0.5 μm) and VOCs show a significant dependency with respect to the intensity as a function of the Manhattan distance to the source. Moreover, we observed differences in the propagation behavior of VOCs, PM, and CO, which are particularly relevant in incipient fire scenarios due to the presence of strand propagation effects.

14 March 2024 in Proceedings
Verified
Conference Paper
Open access
PDF file
Pascal VorwerkPascal Vorwerk
Pascal Vorwerk
JKJörg Kelleter
Jörg Kelleter
SMSteffen Müller
Steffen Müller
UKUlrich Krause
Ulrich Krause
Multi-sensor data from a small laboratory setup was used to create a new feature space with linear discriminant analysis (LDA) to improve the classification of different fire materials. The LDA parameters were applied to a real room dataset to evaluate classification models. Data transformation using LDA improved the classification rate by up to 17% compared to principal component analysis (PCA) approaches used in previous studies.

8 June 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
Pascal VorwerkPascal Vorwerk
Pascal Vorwerk
JKJörg Kelleter
Jörg Kelleter
SMSteffen Müller
Steffen Müller
UKUlrich Krause
Ulrich Krause
This work analyzes a new indoor laboratory data set looking at early fire indicators in controlled and realistic experiments representing different incipient fire scenarios. The experiments were performed within the confines of an indoor laboratory setting using multiple distributed sensor nodes on different room positions. Each sensor node collected data of particulate matter (PM), volatile organic compounds (VOC), CO, CO2, H2, UV, air temperature and humidity in terms of a multivariate time series. These data hold immense value for researchers within the machine learning and data science communities who are keen on exploring innovative advanced statistical and machine learning techniques. They serve as a valuable resource for the development of early fire detection systems. The analysis of the collected data was carried out in dependence of the manhattan distance between the fire source and the sensor node. We found that especially larger particles (> 0.5 μm) and VOCs show a significant dependency with respect to the intensity as a function of the manhattan distance to the source. Moreover, we observed differences in the propagation behavior of VOCs, PM, and CO, which are particularly relevant in incipient fire scenarios due to the presence of strand popagation effects.