The four-meter gait speed (4MGS) is a recommended physical performance test in older adults but is challenging to implement clinically. We developed a smartphone application (App) with a four-meter ribbon for remote 4MGS testing at home. This study aimed to assess the validity and reliability of this smartphone App-based assessment of the home 4MGS. We assessed the validity of the smartphone App by comparing it against a gold standard video assessment of the 4MGS conducted by study staff visiting community-dwelling older adults and against the stopwatch-based measurement. Moreover, we assessed the test–retest reliability in two supervised sessions and three additional sessions performed by the participants independently, without staff supervision. The 4MGS measured by the smartphone App was highly correlated with video-based 4MGS (r = 0.94), with minimal differences (mean = 0.07 m/s, ± 1.96 SD = 0.12) across a range of gait speeds. The test–retest reliability for the smartphone App 4MGS was high (ICC values: 0.75 to 0.93). The home 4MGS in older adults can be measured accurately and reliably using a smartphone in the pants pocket and a four-meter strip of ribbon. Leveraging existing technology carried by a significant portion of the older adult population could overcome barriers in busy clinical settings for this well-established objective mobility test.
Background: Gait speed is a valuable biomarker for mobility and overall health assessment. Existing methods to measure gait speed require expensive equipment or personnel assistance, limiting their use in unsupervised, daily-life conditions. The availability of smartphones equipped with a single inertial measurement unit (IMU) presents a viable and convenient method for measuring gait speed outside of laboratory and clinical settings. Previous works have used the inverted pendulum model to estimate gait speed using a non–smartphone-based IMU attached to the trunk. However, it is unclear whether and how this approach can estimate gait speed using the IMU embedded in a smartphone while being carried in a pants pocket during walking, especially under various walking conditions. Objective: This study aimed to validate and test the reliability of a smartphone IMU–based gait speed measurement placed in the user’s front pants pocket in both healthy young and older adults while walking quietly (ie, normal walking) and walking while conducting a cognitive task (ie, dual-task walking). Methods: A custom-developed smartphone application (app) was used to record gait data from 12 young adults and 12 older adults during normal and dual-task walking. The validity and reliability of gait speed and step length estimations from the smartphone were compared with the gold standard GAITRite mat. A coefficient-based adjustment based upon a coefficient relative to the original estimation of step length was applied to improve the accuracy of gait speed estimation. The magnitude of error (ie, bias and limits of agreement) between the gait data from the smartphone and the GAITRite mat was calculated for each stride. The Passing-Bablok orthogonal regression model was used to provide agreement (ie, slopes and intercepts) between the smartphone and the GAITRite mat. Results: The gait speed measured by the smartphone was valid when compared to the GAITRite mat. The original limits of agreement were 0.50 m/s (an ideal value of 0 m/s), and the orthogonal regression analysis indicated a slope of 1.68 (an ideal value of 1) and an intercept of −0.70 (an ideal value of 0). After adjustment, the accuracy of the smartphone-derived gait speed estimation improved, with limits of agreement reduced to 0.34 m/s. The adjusted slope improved to 1.00, with an intercept of 0.03. The test-retest reliability of smartphone-derived gait speed was good to excellent within supervised laboratory settings and unsupervised home conditions. The adjustment coefficients were applicable to a wide range of step lengths and gait speeds. Conclusions: The inverted pendulum approach is a valid and reliable method for estimating gait speed from a smartphone IMU placed in the pockets of younger and older adults. Adjusting step length by a coefficient derived from the original estimation of step length successfully removed bias and improved the accuracy of gait speed estimation. This novel method has potential applications in various settings and populations, though fine-tuning may be necessary for specific data sets.
Background: Recovery after total hip arthroplasty (THA) and total knee arthroplasty (TKA) is typically assessed with infrequent clinic-based evaluations that may not reflect patients’ everyday mobility. Smartphone inertial sensors enable scalable, repeated gait measurement in real-world settings, but the extent to which prompted walking tests reflect daily life walking during recovery is not well defined. Objective: The objective of this study was to characterize week-by-week recovery trajectories after THA and TKA using high-frequency smartphone sensor data and quantify the difference between prompted in-app walking tests and passive daily life background walking. Methods: We analyzed longitudinal smartphone-based gait measurements from 735 patients (THA, n=350; TKA, n=385) who underwent unilateral surgery between July 2022 and October 2025. Nine spatiotemporal gait parameters were monitored over the first 15 postoperative weeks across 2 conditions: prompted “in-app” walks and passively captured “background” walks. Recovery trajectories were evaluated using Kaplan-Meier time-to-baseline analyses, linear mixed-effects models, and comparison of late-stage plateau levels (weeks 11‐15) using estimated marginal means of the models. Results: Across all parameters, THA patients returned to preoperative baseline levels faster than TKA patients, with mean trajectories generally approaching baseline by week 4 for THA versus weeks 6 to 8 for TKA. Linear mixed-effects models showed that surgical procedure type significantly influenced recovery trajectory for all parameters except single support of the unaffected leg. All gait parameters except stance asymmetry and single support of the unaffected leg exhibited persistent differences through the late-recovery plateau (weeks 11‐15). We also compared prompted “in-app” walks with passively captured background walking. Prompted and passive walking showed systematic divergence in both THA and TKA; prompted assessments generally indicated faster or more complete return to baseline than passive daily life walking. Finally, preoperative gait level was strongly associated with postoperative trajectories, with baseline-stratified analyses showing distinct patterns of recovery between groups. Conclusions: High-frequency smartphone gait assessment quantifies procedure-specific recovery dynamics and demonstrates that prompted tests and passive daily life measurements capture distinct, noninterchangeable functional signals. Parameters from prompted walks plateaued while those from passively captured walks were still changing; prompted testing alone therefore captures only one component of returning function, highlighting the additional information that passive, real-world gait monitoring can provide.
BACKGROUND Gait speed is a valuable biomarker for mobility and health assessment in clinical and research settings. Existing methods to measure gait speed require expensive equipment or personal assistance, limiting their use in unsupervised, daily-life conditions. OBJECTIVE This study aimed to examine the validity and reliability of the inverted pendulum model approach to estimating gait speed and required spatial information (i.e., step length) from data collected with a single smartphone IMU placed in the user’s pants pocket, for both healthy younger and older adults. METHODS A custom-developed smartphone app was used to record gait data from healthy younger and older adults during normal and dual-task walking. Validity and reliability of gait speed and step length estimations from the smartphone were compared with the gold-standard GAITRite mat. A coefficient-based adjustment based upon a coefficient relative to the original estimation of step length was applied to improve the accuracy of gait speed estimation. RESULTS Smartphone-derived gait speed and step length showed good validity compared to the GAITRite mat, with minimal bias and acceptable limits of agreement. The test-retest reliability of app-derived gait speed was good to excellent within supervised laboratory settings and unsupervised home conditions. After adjustment, the accuracy of gait speed estimation improved, with reduced bias. The adjustment coefficients were applicable to a wide range of step lengths and gait speeds. CONCLUSIONS The inverted pendulum approach is a valid and reliable method for estimating gait speed from a smartphone IMU placed in the pocket of younger and older adults. Adjusting step length by a coefficient derived from the original estimation of step length successfully removed bias and improved the accuracy of gait speed estimation. This novel method has potential applications in various settings and populations, though fine-tuning may be necessary for specific datasets.