31 August 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
YZYixuan Zhang
Yixuan Zhang
ZWZoujun Wang
Zoujun Wang
KFKaiwen Feng
Kaiwen Feng
YZYirui Zhang
Yirui Zhang
ZTZhitong Tian
Zhitong Tian
HLHailiang Lu
Hailiang Lu
Transmission tower grounding safety is a critical element that significantly impacts the reliability and sustainability of power grids. Tower grounding resistance is a significant grounding characteristic parameter. In order to accurately measure the grounding resistance of towers using the clamp meter method in both single-tower and multi-tower parallel scenarios, this paper establishes theoretical calculation models for measuring tower grounding resistance using the clamp meter method. Considering the interaction between the artificial grounding device and the tower foundation, this paper models and simulates transmission towers and lightning shield wires, analyzing the influencing factors on the grounding resistance measurement results using the clamp meter method in both single- and multi-tower parallel scenarios. The results show that for single towers, the clamp meter measurement results increase with decreasing foundation root spacing and increasing length of the artificial device’s extension lines, but the changes are relatively small. In multi-tower grounding scenarios, due to the shunting effect of the parallel branches formed by the towers and lightning shield wires, the value is smaller than in single-tower grounding scenarios. Changing the number of parallel towers and the type of lightning shield wire produces little effect on the measurement results. However, changes in soil resistivity have the most significant impact. Therefore, correction formulas for the impact of soil resistivity on clamp meter measurements are proposed and then verified by applying them to field tests.

15 July 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YZYixuan Zhang
Yixuan Zhang
XZXuwei Zhou
Xuwei Zhou
FWFengrun Wang
Fengrun Wang
SCSheng Cheng
Sheng Cheng
YFYang Fan
Yang Fan
HLHailiang Lu
Hailiang Lu
At present, the precise location of fault tower struck by lightning still relies on manual line inspection, the search process is time-consuming and laborious. This paper proposes a lightning-strike fault tower localization criterion based on detection of residual magnetism on the tower. This paper firstly calculates the tower shunt coefficient of lightning current under different lightning striking faults. After a transmission tower is struck by lightning, residual magnetism is generated in the tower. An experiment platform is designed to study the residual magnetism characteristics of the fault and adjacent towers in the cases of both back flashover and shielding failure flashover at 110 kV, 220 kV and 500 kV voltage level. The specific values of residual magnetism under different conditions are obtained, and it is found that the residual magnetism of the fault tower is far larger than that of the adjacent towers. Besides, the effect of power frequency follow current during the flashover is also taken into account. Based on the experimental results, the residual magnetism law is summarized, and the criterion of lightning-struck tower localization and fault identification based on residual magnetism detection is proposed. Finally a field test was conducted which verified the validity of the method proposed.