Touko Kaasalainen

Dr. Touko Kaasalainen

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2021 in Physica Medica
Verified
Journal Article
Closed access
TKTouko Kaasalainen
Touko Kaasalainen
MEMarja Ekholm
Marja Ekholm
TSTeemu Siiskonen
Teemu Siiskonen
MKMika Kortesniemi
Mika Kortesniemi

1 December 2015 in Physica Medica
Verified
Journal Article
Closed access
TKTimo Kiljunen
Timo Kiljunen
TKTouko Kaasalainen
Touko Kaasalainen
ASAnni Suomalainen
Anni Suomalainen
MKMika Kortesniemi
Mika Kortesniemi

1 July 2014 in American Journal of Roentgenology
Verified
Journal Article
Closed access
TKTouko Kaasalainen
Touko Kaasalainen
KPKirsi Palmu
Kirsi Palmu
VRVappu Reijonen
Vappu Reijonen
MKMika Kortesniemi
Mika Kortesniemi
The objective of our study was to evaluate the effect of vertical centering on dose and image noise in chest MDCT of different-sized patients using anthropomorphic phantoms and retrospectively studying examinations of clinical patients. Three different anthropomorphic phantoms were scanned using different vertical centering (offset ± 6 cm) and were assessed with radiation dose-monitoring software. The effect of vertical positioning on the radiation dose was studied using the volume CT dose index, dose-length product, and size-specific dose estimates for different-sized phantoms. Image noise was determined from CT number histograms. Vertical positioning for chest CT examinations of 112 patients ranging from neonates to adults were retrospectively assessed. Radiation doses were highest when using the posteroanterior scout image for automatic exposure control (AEC) and when phantoms were set in the lowest table position, and radiation doses were lowest when phantoms were set in the uppermost table position. For the adult phantom, relative doses increased by 38% in the lowest table position and decreased by 23% in the highest table position. Similarly, doses for pediatric 5-year-old and newborn phantoms were 21% and 12% higher in the lowest table position and 12% and 8% lower in the highest table position, respectively. The effect decreased when a lateral scout image was used for AEC. The relative noise was lowest when the phantoms were properly centered and increased with vertical offset. In clinical patients, we observed offset with a median value varying from 25 to 35 mm below the isocenter. Regardless of patient size, most patients in this study were positioned too low, which negatively affected both patient dose and image noise. Miscentering was more pronounced in smaller pediatric patients.

1 January 2015 in American Journal of Roentgenology
Verified
Journal Article
Closed access
UNUlla Nikupaavo
Ulla Nikupaavo
TKTouko Kaasalainen
Touko Kaasalainen
VRVappu Reijonen
Vappu Reijonen
SASanna-Mari Ahonen
Sanna-Mari Ahonen
MKMika Kortesniemi
Mika Kortesniemi
The purpose of this study was to study different optimization methods for reducing eye lens dose in head CT. Two anthropomorphic phantoms were scanned with a routine head CT protocol for evaluation of the brain that included bismuth shielding, gantry tilting, organ-based tube current modulation, or combinations of these techniques. Highsensitivity metal oxide semiconductor field effect transistor dosimeters were used to measure local equivalent doses in the head region. The relative changes in image noise and contrast were determined by ROI analysis. The mean absorbed lens doses varied from 4.9 to 19.7 mGy and from 10.8 to 16.9 mGy in the two phantoms. The most efficient method for reducing lens dose was gantry tilting, which left the lenses outside the primary radiation beam, resulting in an approximately 75% decrease in lens dose. Image noise decreased, especially in the anterior part of the brain. The use of organ-based tube current modulation resulted in an approximately 30% decrease in lens dose. However, image noise increased as much as 30% in the posterior and central parts of the brain. With bismuth shields, it was possible to reduce lens dose as much as 25%. Our results indicate that gantry tilt, when possible, is an effective method for reducing exposure of the eye lenses in CT of the brain without compromising image quality. Measurements in two different phantoms showed how patient geometry affects the optimization. When lenses can only partially be cropped outside the primary beam, organ-based tube current modulation or bismuth shields can be useful in lens dose reduction.

1 January 2015 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
PPPauli Pöyhönen
Pauli Pöyhönen
AHAnita Hiippala
Anita Hiippala
LOLaura Ollila
Laura Ollila
TKTouko Kaasalainen
Touko Kaasalainen
HHHelena Hänninen
Helena Hänninen
MHMiia Holmström
Miia Holmström
Autosomal dominantly inherited PRKAG2 cardiac syndrome is due to a unique defect of the cardiac cell metabolism and has a distinctive histopathology with excess intracellular glycogen, and prognosis different from sarcomeric hypertrophic cardiomyopathy. We aimed to define the distinct characteristics of PRKAG2 using cardiovascular magnetic resonance (CMR). CMR (1.5 T) and genetic testing were performed in two families harboring PRKAG2 mutations. On CMR, segmental analysis of left ventricular (LV) hypertrophy (LVH), function, native T1 mapping, and late gadolinium enhancement (LGE) were performed. Six individuals (median age 23 years, range 16–48; two females) had a PRKAG2 mutation: five with an R302Q mutation (family 1), and one with a novel H344P mutation (family 2). Three of six mutation carriers had LV mass above age and gender limits (203 g/m2, 157 g/m2 and 68 g/m2) and others (with R302Q mutation) normal LV masses. All mutation carriers had LVH in at least one segment, with the median maximal wall thickness of 13 mm (range 11–37 mm). Two R302Q mutation carriers with markedly increased LV mass (203 g/m2 and 157 g/m2) showed a diffuse pattern of hypertrophy but predominantly in the interventricular septum, while other mutation carriers exhibited a non-symmetric mid-infero-lateral pattern of hypertrophy. In family 1, the mutation negative male had a mean T1 value of 963 ms, three males with the R302Q mutation, LVH and no LGE a mean value of 918 ± 11 ms, and the oldest male with the R302Q mutation, extensive hypertrophy and LGE a mean value of 973 ms. Of six mutations carriers, two with advanced disease had LGE with 11 and 22 % enhancement of total LV volume. PRKAG2 cardiac syndrome may present with eccentric distribution of LVH, involving focal mid-infero-lateral pattern in the early disease stage, and more diffuse pattern but focusing on interventricular septum in advanced cases. In patients at earlier stages of disease, without LGE, T1 values may be reduced, while in the advanced disease stage T1 mapping may result in higher values caused by fibrosis. CMR is a valuable tool in detecting diffuse and focal myocardial abnormalities in PRKAG2 cardiomyopathy.

23 January 2013 in Pediatric Radiology
Verified
Journal Article
Closed access
PDF file
TKTouko Kaasalainen
Touko Kaasalainen
KPKirsi Palmu
Kirsi Palmu
ALAnniina Lampinen
Anniina Lampinen
MKMika Kortesniemi
Mika Kortesniemi