Giovanna Beccia

Dr. Giovanna Beccia

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
DNDania Nachira
Dania Nachira
GPGiovanni Punzo
Giovanni Punzo
GCGiuseppe Calabrese
Giuseppe Calabrese
FSFlaminio Sessa
Flaminio Sessa
MCMaria Teresa Congedo
Maria Teresa Congedo
SMStefano Margaritora
Stefano Margaritora
Background: To evaluate the analgesic efficacy of continuous erector spinae plane block(c-ESPB) and serratus anterior plane block(c-SAPB) versus the intercostal nerve block (ICNB) in Uniportal-VATS in terms of pain control, drug consumption, and complications. Methods: Ninety-three consecutive patients, undergone one of the three peripheral nerve blocks after Uniportal-VATS, were prospectively enrolled. A 1:1 propensity score matching was used to minimize bias. Results: C-ESPB and c-SAPB groups had no difference in morphine request upon awakening compared to ICNB. A higher VAS-score was recorded in c-ESPB compared to ICNB in the first 12 h after surgery. A significantly lower consumption of paracetamol in II postoperative day (p.o.d.) and tramadol in I and II p.o.d. was recorded in the c-ESPB group compared to the ICNB group. A higher dynamic VAS score was recorded at 24 h and 48 h in the ICNB group compared to the c-SAPB. No difference was found in safety, VAS-score and drug consumption between c-ESPB and c-SAPB at any given time, except for a higher tramadol request in c-SAPB in II p.o.d. Conclusions: C-ESPB and c-SAPB appear to have the same safety and analgesic efficacy when compared between them and to ICNB in Uniportal-VATS approach. C-ESPB showed a delayed onset of analgesic effect and a lower postoperative drug consumption compared to ICNB.

20 September 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
GPGiovanni Punzo
Giovanni Punzo
GBGiovanna Beccia
Giovanna Beccia
CCChiara Cambise
Chiara Cambise
TITiziana Iacobucci
Tiziana Iacobucci
FSFlaminio Sessa
Flaminio Sessa
PAPaola Aceto
Paola Aceto
Background: Intraoperative fluid management based on pulse pressure variation has shown potential to reduce postoperative pulmonary complications (PPCs) and improve clinical outcomes in various surgical settings. However, its efficacy and safety have not been assessed in patients undergoing thoracic surgery with one-lung ventilation. Methods: Patients scheduled for pulmonary lobectomy using uniportal video-assisted thoracic surgery approach were randomly assigned to two groups. In the PPV group, fluid administration was guided by the pulse pressure variation parameter, while in the near-zero group, it was guided by conventional hemodynamic parameters. The primary outcome was the partial pressure of oxygen (PaO2)/ fraction of inspired oxygen (FiO2) ratio 15 min after extubation. The secondary outcomes included extubation time, the incidence of postoperative pulmonary complications in the first three postoperative days, and the length of hospital stay. Results: The PaO2/FiO2 ratio did not differ between the two groups (364.48 ± 38.06 vs. 359.21 ± 36.95; p = 0.51), although patients in the PPV group (n = 44) received a larger amount of both crystalloids (1145 ± 470.21 vs. 890 ± 459.31, p = 0.01) and colloids (162.5 ± 278.31 vs 18.18 ± 94.68, p = 0.002) compared to the near-zero group (n = 44). No differences were found in extubation time, type and number of PPCs, and length of hospital stay. Conclusions: PPV-guided fluid management in thoracic surgery requiring one-lung ventilation does not improve pulmonary gas exchange as measured by the PaO2/FiO2 ratio and does not seem to offer clinical benefits. Additionally, it results in increased fluid administration compared to fluid management based on conventional hemodynamic parameters.