Petr Dobsak

Prof. Dr. Petr Dobsak

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2011 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
PDPetr Dobsak
Petr Dobsak
PHPavel Homolka
Pavel Homolka
JSJan Svojanovsky
Jan Svojanovsky
ARAnna Reichertova
Anna Reichertova
MSMiroslav Soucek
Miroslav Soucek
JSJarmila Siegelova
Jarmila Siegelova

19 November 2015 in SpringerPlus
Verified
Journal Article
Open access
PDF file
Adam ChromyAdam Chromy
Adam Chromy
LZLudek Zalud
Ludek Zalud
PDPetr Dobsak
Petr Dobsak
ISIgor Suskevic
Igor Suskevic
VMVeronika Mrkvicova
Veronika Mrkvicova
Limb volume measurements are used for evaluating growth of muscle mass and effectivity of strength training. Beside sport sciences, it is used e.g. for detection of oedemas, lymphedemas or carcinomas or for examinations of muscle atrophy. There are several commonly used methods, but there is a lack of clear comparison, which shows their advantages and limits. The accuracy of each method is uncertainly estimated only. The aim of this paper is to determine and experimentally verify their accuracy and compare them among each other. Water Displacement Method (WD), three methods based on circumferential measures—Frustum Sign Model (FSM), Disc Model (DM), Partial Frustum Model (PFM) and two 3D scan based methods Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) were compared. Precise reference cylinders and limbs of two human subjects were measured 10 times by each method. Personal dependency of methods was also tested by measuring 10 times the same object by 3 different people. Accuracies: WD 0.3 %, FSM 2–8 % according person, DM, PFM 1–8 %, MRI 2 % (hand) or 8 % (finger), CT 0.5 % (hand) or 2 % (finger);times: FSM 1 min, CT 7 min, WD, DM, PFM 15 min, MRI 19 min; and more. WD was found as the best method for most of uses with best accuracy. The CT disposes with almost the same accuracy and allows measurements of specific regions (e.g. particular muscles), as same as MRI, which accuracy is worse though, but it is not harmful. Frustum Sign Model is usable for very fast estimation of limb volume, but with lower accuracy, Disc Model and Partial Frustum Model is useful in cases when Water Displacement cannot be used.

6 August 2012 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
PDPetr Dobsak
Petr Dobsak
JTJosef Tomandl
Josef Tomandl
LSLenka Spinarova
Lenka Spinarova
JVJiri Vitovec
Jiri Vitovec
LDLadislav Dušek
Ladislav Dušek
PHPavel Homolka
Pavel Homolka

1 April 2014 in Biomedical Papers
Verified
Journal Article
Open access
PDF file
VSVladimir Soska
Vladimir Soska
PDPetr Dobsak
Petr Dobsak
MPMichal Pohanka
Michal Pohanka
LSLenka Spinarova
Lenka Spinarova
JVJiri Vitovec
Jiri Vitovec
JSJarmila Siegelova
Jarmila Siegelova
Aim: Both aerobic training (AT) and electromyostimulation (EMS) of leg muscles improve exercise tolerance in patients suffering from chronic heart failure (CHF). It was speculated that combination of both methods might have an additive effect. ...

1 March 2004
Verified
Journal Article
Closed access
JEJean-Christophe Eicher
Jean-Christophe Eicher
LNLaurence De Nadai
Laurence De Nadai
FSFrancois-Xavier Soto
Francois-Xavier Soto
SFSylvie Falcon-Eicher
Sylvie Falcon-Eicher
PDPetr Dobsak
Petr Dobsak
JWJean-Eric Wolf
Jean-Eric Wolf

1 February 2023 in International Journal Of Clinical Practice
Verified
Journal Article
Open access
PDF file
AHAlena Havelkova
Alena Havelkova
PDPetr Dvořák
Petr Dvořák
JSJarmila Siegelova
Jarmila Siegelova
PDPetr Dobsak
Petr Dobsak
PFPetr Filipensky
Petr Filipensky
GCGermaine Cornelissen
Germaine Cornelissen
Aim. Specify the risk rate of incorrect patient classification based on the night-to-day ratio specification from singular 24-h ABPM in comparison to the results of 7-day ABPM monitoring Materials and Methods. 1197 24 h cycles were enrolled in 171 subjects in the study and divided into 4 groups: group 1 (40 healthy men and women without exercise), group 2 (40 healthy exercise-training men and women), group 3 (40 patients with ischemic coronary artery disease without exercise), and group 4 (51 patients with ischemic coronary artery disease following cardiovascular rehabilitation). The subject of the evaluation was the percentage rate of incorrect subject classification (dipper, nondipper, extreme dipper, and riser) based on the mean blood pressure values for 7 days and from seven independent 24-hour cycles (the mean value mode). Results. In the case of the individuals included in the monitored groups, the mean night-to-day ratio-based (mode for the 7 days versus the individual days of 24-hour monitoring) classification accordance ranged between 59% and 62%. Only in singular cases did the accordance reach 0% or 100%. The accordance size was not dependent on the health or cardiovascular disease ( ; 56% vs. 54%) or physical activity ( ; 55% vs. 54%) of the monitored individuals. Conclusion. The specification of the night-to-day ratio of each individual for each day of the 7-day ABPM monitoring would be the most convenient option. In many patients, diagnosing could thus be based on the most frequently occurring values (mode specification). The study protocol was registered with ClinicalTrials.gov (NCT05264090)