Limb volume measurements are used for evaluating growth of muscle mass and effectivity of strength training. Beside sport sciences, it is used e.g. for detection of oedemas, lymphedemas or carcinomas or for examinations of muscle atrophy. There are several commonly used methods, but there is a lack of clear comparison, which shows their advantages and limits. The accuracy of each method is uncertainly estimated only. The aim of this paper is to determine and experimentally verify their accuracy and compare them among each other. Water Displacement Method (WD), three methods based on circumferential measures—Frustum Sign Model (FSM), Disc Model (DM), Partial Frustum Model (PFM) and two 3D scan based methods Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) were compared. Precise reference cylinders and limbs of two human subjects were measured 10 times by each method. Personal dependency of methods was also tested by measuring 10 times the same object by 3 different people. Accuracies: WD 0.3 %, FSM 2–8 % according person, DM, PFM 1–8 %, MRI 2 % (hand) or 8 % (finger), CT 0.5 % (hand) or 2 % (finger);times: FSM 1 min, CT 7 min, WD, DM, PFM 15 min, MRI 19 min; and more. WD was found as the best method for most of uses with best accuracy. The CT disposes with almost the same accuracy and allows measurements of specific regions (e.g. particular muscles), as same as MRI, which accuracy is worse though, but it is not harmful. Frustum Sign Model is usable for very fast estimation of limb volume, but with lower accuracy, Disc Model and Partial Frustum Model is useful in cases when Water Displacement cannot be used.
Aim: Both aerobic training (AT) and electromyostimulation (EMS) of leg muscles improve exercise tolerance in patients suffering from chronic heart failure (CHF). It was speculated that combination of both methods might have an additive effect. ...
Aim. Specify the risk rate of incorrect patient classification based on the night-to-day ratio specification from singular 24-h ABPM in comparison to the results of 7-day ABPM monitoring Materials and Methods. 1197 24 h cycles were enrolled in 171 subjects in the study and divided into 4 groups: group 1 (40 healthy men and women without exercise), group 2 (40 healthy exercise-training men and women), group 3 (40 patients with ischemic coronary artery disease without exercise), and group 4 (51 patients with ischemic coronary artery disease following cardiovascular rehabilitation). The subject of the evaluation was the percentage rate of incorrect subject classification (dipper, nondipper, extreme dipper, and riser) based on the mean blood pressure values for 7 days and from seven independent 24-hour cycles (the mean value mode). Results. In the case of the individuals included in the monitored groups, the mean night-to-day ratio-based (mode for the 7 days versus the individual days of 24-hour monitoring) classification accordance ranged between 59% and 62%. Only in singular cases did the accordance reach 0% or 100%. The accordance size was not dependent on the health or cardiovascular disease ( ; 56% vs. 54%) or physical activity ( ; 55% vs. 54%) of the monitored individuals. Conclusion. The specification of the night-to-day ratio of each individual for each day of the 7-day ABPM monitoring would be the most convenient option. In many patients, diagnosing could thus be based on the most frequently occurring values (mode specification). The study protocol was registered with ClinicalTrials.gov (NCT05264090)