Combining various sources to create a complementary system plays a key role in utilizing clean energy sources economically and mitigating air pollution during the heating season in Northern China. However, there is a lack of unified and reasonable design methods for such systems, resulting in the excessive capacity of equipment and the waste of energy. In this work, a unified design method is proposed to solve this problem. A generalized structure and its mathematical model are firstly established, enabling transient simulations on the TRNSYS platform. Then, a preliminary screening criterion for the system composition a general operation strategy is proposed. Finally, the system configuration is optimized by using the genetic algorithm. The method is successfully applied in a demonstration project in China. The results show that the coupling system consisting of a biomass boiler (384 kW), an air-source heat pump (430 kW) and a ground-source heat pump (369 kW) is the most economical, and the annual cost is 26.7% lower than that of a single-equipment system. Additionally, the sensitive factors that strongly affect the optimization results are explored. The establishment of the generalized structure and its mathematical model enables the quick calculation and convenient comparison of various schemes, and simplifies the complicated optimization problem of the capacity optimization of each piece of equipment. The proposed design method can reduce the annual cost to a minimum value, and thus it provides a theoretical basis for the large-scale application of clean energy sources for heating.
An integrated energy system (IES) plays a key role in transforming energy consumption patterns and solving serious environmental and economic problems. However, the abundant optional schemes and the complex coupling relationship among each piece of equipment make the optimization of an IES very complicated, and most of the current literature focuses on optimization of a specific system. In this work, a simulation-based two-step decoupling method is proposed to simplify the optimization of an IES. The generalized IES is split into four subsystems, and a two-layer optimization method is applied for optimization of the capacity of each piece of equipment. The proposed method enables fast comparison among abundant optional configurations of an IES, and it is applied to a hospital in Beijing, China. The optimized coupling system includes the gas-fired trigeneration system, the GSHP, and the electric chiller. Compared with the traditional distributed systems, the emission reduction rate of CO2 and NOX for the coupling system reaches 153.8% and 314.5%, respectively. Moreover, the primary energy consumption of the coupling system is 82.67% less than that of the traditional distributed energy system, while the annual cost is almost at the same level.