Hongxing Qi

Dr. Hongxing Qi


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2022 in Frontiers in Chemistry
Verified
Journal Article
Open access
XCXi Chen
Xi Chen
JLJingzhou Li
Jingzhou Li
YZYichi Zhong
Yichi Zhong
XLXin Li
Xin Li
MPMingzhong Pan
Mingzhong Pan
LZLong Zhang
Long Zhang
Semiconductor quantum dots (QDs) are a promising luminescent phosphor for next-generation lightings and displays. In particular, QD-based white light-emitting diodes (WLEDs) are considered to be the candidate light sources with the most potential for application in displays. In this work, we synthesized quaternary/ternary core/shell alloyed CdZnSeS/ZnSeS QDs with high bright emission intensity. The QDs show good thermal stability by performing high temperature-dependent experiments that range from 295 to 433 K. Finally, the WLED based on the CdZnSeS/ZnSeS QDs exhibits a luminous efficiency (LE) of 28.14 lm/W, an external quantum efficiency (EQE) of 14.86%, and a warm bright sunlight close to the spectrum of daylight (Commission Internationale de l'éclairage (CIE) coordinates 0.305, 0.371). Moreover, the photoluminescence (PL) intensity, LE, EQE, and correlated color temperature (CCT) of as-prepared QD WLED remained relatively stable with only slight changes in the luminescence stability experiment.

12 December 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZPZhao Pengyang
Zhao Pengyang
JDJiuchang Deng
Jiuchang Deng
CXChengwen Xing
Chengwen Xing
FMFanchao Meng
Fanchao Meng
LMLingqiang Meng
Lingqiang Meng
JWJian-yu Wang
Jian-yu Wang
A spaceborne mounting method for fixing a 100 × 100 × 100 mm cubic Fabry–Pérot (FP) cavity is presented. The method constrains the FP cavity in eight directions with a titanium bracket, PEEK gaskets, and vacuum glue. Three criteria were proposed for judging whether the FP cavity is offset or not during aerospace vibration tests. Results indicate that the proposed method is a reliable, robust, and stable way to fix a cubic FP cavity in ultra-stable lasers (USLs). This approach paves the way for the use of USLs in space.

15 November 2024 in Photonics
Verified
Journal Article
Open access
PDF file
ZPZhao Pengyang
Zhao Pengyang
FMFanchao Meng
Fanchao Meng
JXJunyang Xiong
Junyang Xiong
JJJia Jianjun
Jia Jianjun
LMLingqiang Meng
Lingqiang Meng
HQHongxing Qi
Hongxing Qi
Acousto-optic modulators (AOMs) have been widely used in ultra-stable lasers (USLs) for optimizing its performances. A thermal theoretical model of the AOM, which is made by TeO2, was established. Based on the model, the temperature coefficients of the diffraction angle and efficiency were calculated to be 4.051 μrad/°C and 0.018%/°C. The influences of thermal effects of the AOM on USLs’ cavity coupling and frequency stability were firstly studied. A 1 °C temperature change in the AOM results in a 0.31 Hz frequency fluctuation of the laser within the USL cavity. Simulation and experimental results indicate that, to achieve USLs’ optimal performance, thermal effects of AOMs within the system must be addressed and managed.

6 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
WYWenHang Yang
WenHang Yang
CCChen Cao
Chen Cao
PHPujiang Huang
Pujiang Huang
JBJindong Bai
Jindong Bai
BZBangjian Zhao
Bangjian Zhao
HQHongxing Qi
Hongxing Qi
High-precision temperature control of large-area blackbodies has a pivotal role in temperature calibration and thermal imaging correction. Meanwhile, it is necessary to correct the temperature difference between the radiating (surface of use) and back surfaces (where the temperature sensor is installed) of the blackbody during the testing phase. Moreover, large-area blackbodies are usually composed of multiple temperature control channels, and manual correction in this scenario is error-prone and inefficient. At present, there is no method that can achieve temperature-automated calibration for a large-area blackbody radiation source. Therefore, this article is dedicated to achieving temperature-automated calibration for a large-area blackbody radiation source. First, utilizing two calibrated infrared thermometers, the optimal temperature measurement location was determined using a focusing algorithm. Then, a three-axis movement system was used to obtain the true temperature at the same measurement location on a large-area blackbody surface from different channels. This temperature was subtracted from the blackbody’s back surface. The temperature difference was calculated employing a weighted algorithm to derive the parameters for calibration. Finally, regarding experimental verification, the consistency error of the temperature measurement point was reduced by 85.4%, the temperature uniformity of the surface source was improved by 40.4%, and the average temperature measurement deviation decreased by 43.8%. In addition, this system demonstrated the characteristics of strong environmental adaptability that was able to perform temperature calibration under the working conditions of a blackbody surface temperature from 100 K to 573 K, which decreased the calibration time by 9.82 times.

8 July 2025 in Communications Engineering
Verified
Journal Article
Open access
PDF file
JBJindong Bai
Jindong Bai
WYWenhang Yang
Wenhang Yang
SZShouzheng Zhu
Shouzheng Zhu
HJHaijun Jin
Haijun Jin
YZYuchen Zhang
Yuchen Zhang
LSLiu Shijie
Liu Shijie
In applications such as those in the semiconductor industry, precise temperature measurements with low power consumption are crucial. This article presents a novel noncontact temperature measurement method with low power consumption and high precision, and a thermopile sensor-based linear array for surface temperature measurements is used in semiconductor manufacturing and temperature calibration applications. The array consists of 15 thermopile sensors, a negative temperature coefficient (NTC) thermistor, an FPGA control board with a fiber optic interface, and a motion module. Moreover, the total power consumption of the board is less than 1.5 W. On the FPGA control board, a multiparameter temperature compensation algorithm is used to address intrinsic temperature differences and consistency errors among the sensors. Compared with the traditional two-point calibration method, the temperature measurement accuracy of the proposed method reaches 26 mK in the temperature range of 293–303 K, the maximum repeatability error of the sensor is less than 5.5 mK, and the non-uniformity error between 15 sensors is less than 11.9 mK. The array and its replicas were subjected to more than 6 h of rigorous testing, demonstrating their high stability, with the reduction in accuracy not exceeding 1.5 mK.

27 April 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YGYue Guo
Yue Guo
JYJinke Yang
Jinke Yang
HQHongxing Qi
Hongxing Qi
LMLingqiang Meng
Lingqiang Meng
JJJia Jianjun
Jia Jianjun
In the detection of gravitational waves in space, during the science phase of the mission, the point-ahead angle mechanism (PAAM) serves to steer a laser beam to compensate for the angle generated by the relative motion of the two spacecrafts (SCs) during the approximately 10 s of flight time a laser beam will take from one SC to reach a distant SC of three million kilometers away. The Tilt-to-length (TTL) noise budget for the PAAM is constrained to less than 8 pm/Hz within the frequency range of 1 mHz to 1 Hz. This constraint requires that the measurement noise of the interferometer remains below this threshold to guarantee the precision needed for gravitational wave detection in space. In the present work, an equal-arm heterodyne interferometer, which is fixed in a vacuum system with multilayer thermal shields, is proposed for the OPD (Optical Path Difference) measurement. The background measurement noise of the system is smaller than 60 pm/Hz within the frequency range of 1 mHz to 1 Hz. This corresponds to an 84.6% noise reduction at 1 mHz compared to similar unshielded interferometers utilizing conventional bonding methods, demonstrating that the proposed system effectively suppresses measurement noises, particularly thermal noise, in the low-frequency range.