Luca Schwarzenbacher

Dr. Luca Schwarzenbacher

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2020 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
VRVeronika Röggla
Veronika Röggla
ALAchim Langenbucher
Achim Langenbucher
CLChristina Leydolt
Christina Leydolt
DSDaniel Schartmüller
Daniel Schartmüller
LSLuca Schwarzenbacher
Luca Schwarzenbacher
RMRupert Michael Menapace
Rupert Michael Menapace
Aims To provide clinical guidance on the use of intraocular lens (IOL) power calculation formulas according to the biometric parameters. Methods 611 eyes that underwent cataract surgery were retrospectively analysed in subgroups according to the axial length (AL) and corneal power (K). The predicted residual refractive error was calculated and compared to evaluate the accuracy of the following formulas: Haigis, Hoffer Q, Holladay 1 and SRK/T. Furthermore, the percentages of eyes with ≤±0.25, ≤±0.5 and 1 dioptres (D) of the prediction error were recorded. Results The Haigis formula showed the highest percentage of cases with ≤0.5 D in eyes with a short AL and steep K (90%), average AL and steep cornea (73.2%) but also in long eyes with a flat and average K (65% and 72.7%, respectively). The Hoffer Q formula delivered the lowest median absolute error (MedAE) in short eyes with an average K (0.30 D) and Holladay 1 in short eyes with a steep K (Holladay 1 0.24 D). SRK/T presented the highest percentage of cases with ≤0.5 D in average long eyes with a flat and average K (80.5% and 68.1%, respectively) and the lowest MedAE in long eyes with an average K (0.29 D). Conclusion Overall, the Haigis formula shows accurate results in most subgroups. However, attention must be paid to the axial eye length as well as the corneal power when choosing the appropriate formula to calculate an IOL power, especially in eyes with an unusual biometry.

1 December 2020 in American Journal of Ophthalmology
Verified
Journal Article
Open access
DSDaniel Schartmüller
Daniel Schartmüller
LSLuca Schwarzenbacher
Luca Schwarzenbacher
EMElias Laurin Meyer
Elias Laurin Meyer
SSSabine Schriefl
Sabine Schriefl
CLChristina Leydolt
Christina Leydolt
RMRupert Michael Menapace
Rupert Michael Menapace
To compare rotational stability and its influencing factors in 3 different widely used hydrophobic acrylic intraocular lenses (IOLs) from the end of surgery (EoS) to 4-7 months (6 months) in over 380 eyes. Prospective interventional comparative clinical study. Setting: Department of Ophthalmology, Medical University of Vienna. A total of 381 eyes of 199 patients with age-related cataract received an IOL Acrysof SN60WF, Tecnis ZCB00, or Envista MX60 in a consecutive order. Implantation of an Acrysof, Tecnis, or Envista IOL randomized to the 0 ± 10, 45 ± 10, 90 ± 10, or 135 ± 10° axis in 1 or both eyes. Baseline measurement was performed with patients supine still on the operating table. Postoperative follow-ups were conducted after 1 hour, 1 week, 1 month, and 6 months. Difference of absolute rotation from the EoS to 6 months. Absolute rotations from the EoS to 6 months were 1.65 ± 2.1, 2.65 ± 4.1, and 3.18 ± 5.8° for the Acrysof, Tecnis, and Envista group, respectively. Rotational stability was statistically significantly superior in the Acrysof compared with the Envista group (P = .014), but not compared with the Tecnis group (P = .10). No significant difference was found between the Tecnis and Envista groups (P = .761). Maximum values of 15.8, 38.6, and 44.9° were observed for the Acrysof, Tecnis, and Envista group, respectively. The Acrysof IOL showed the least amount of absolute rotation compared with the Tecnis and Envista IOLs. Outliers possibly requiring secondary intervention were observed in all groups. The amount of rotation was greatest during the first postoperative hour.

8 November 2023 in American Journal of Ophthalmology
Verified
Journal Article
Open access
VDVictor Danzinger
Victor Danzinger
DSDaniel Schartmüller
Daniel Schartmüller
MLMarcus Lisy
Marcus Lisy
MSMarkus Schranz
Markus Schranz
LSLuca Schwarzenbacher
Luca Schwarzenbacher
CLChristina Leydolt
Christina Leydolt
To compare intraindividual differences in visual performance of a monofocal and enhanced monofocal intraocular lens (IOL) of the same platform. Prospective, interventional, fellow-eye comparison clinical study. In total, 55 patients (110 eyes) with bilateral age-related cataract were enrolled. All patients received a monofocal ZCB00 IOL in the dominant and an enhanced monofocal Eyhance ICB00 IOL in the nondominant eye. After 2 to 4 months, monocular best-corrected distant visual acuity (BCDVA), distance-corrected intermediate visual acuity (DCIVA), distance-corrected near visual acuity (DCNVA), contrast visual acuity, monocular defocus curves, internal higher-order aberrations (HOAs) and spherical aberrations (SA), decentration, and tilt were compared. The monocular mean BCDVA, DCIVA at 80 cm and 66 cm, and DCNVA were -0.03 ± 0.07, 0.24 ± 0.12, 0.32 ± 0.13, and 0.50 ± 0.13 logarithm of the minimum angle of resolution for the enhanced ICB00 and -0.06 ± 0.06 (P = .014), 0.30 ± 0.11 (P = .005), 0.38 ± 0.12 (P = .004), and 0.55 ± 0.14 (P = .034) logarithm of the minimum angle of resolution for the ZCB00, respectively. Internal HOAs (P = .001) and negative SA (P < .001) were increased with the ICB00 at 3 mm and comparable at 5 mm (P > .05). Contrast acuity, tilt, and decentration were similar (P > .05). Significantly increased monocular DCIVA at 80 cm and 66 cm and DCNVA at 40 cm were observed with the enhanced ICB00 IOL, and the ZCB00 IOL demonstrated better BCDVA. This would result in a mean gain of 2 to 3 Early Treatment of Diabetic Retinopathy Study letters at near and intermediate distance. Monocular defocus curves displayed highest differences of 5 Early Treatment of Diabetic Retinopathy Study letters at -1.25 diopters (D) and -1.50 D levels of defocus and a depth of focus of 1.23 D for the ICB00 IOL and 0.94 D for the ZCB00 IOL. Decentration, tilt, and HOAs were generally low.

31 October 2023 in Ophthalmology
Verified
Journal Article
Open access
DSDaniel Schartmüller
Daniel Schartmüller
VRVeronika Röggla
Veronika Röggla
LSLuca Schwarzenbacher
Luca Schwarzenbacher
EMElias Laurin Meyer
Elias Laurin Meyer
CAClaudette Abela-Formanek
Claudette Abela-Formanek
RMRupert Michael Menapace
Rupert Michael Menapace
To evaluate the influence of a capsular tension ring (CTR) on rotational stability, decentration, tilt, and axial stability of an 11.0-mm plate haptic intraocular lens (IOL). Intraindividual, randomized, double-masked, controlled clinical trial. Patients scheduled for sequential same-day bilateral cataract surgery. All patients were randomized to receive a CTR and a plate haptic IOL in one eye and a plate haptic IOL in the fellow eye only. Intraocular lens axis assessment was performed at the end of surgery, 1 hour, 1 week, 1 month, and 6 months using a high-precision evaluation method. Decentration and tilt of the crystalline and pseudophakic lenses were assessed before surgery and at 1 week and 6 months using an anterior segment OCT. Rotational stability from the end of surgery to 6 months and at all follow-up visits, decentration and tilt at 6 months, and differences in axial shift between 1 week and 6 months. One hundred thirty eyes of 65 patients were included in the study. Absolute rotation from the end of surgery to 6 months was 2.8 ± 3.9° and 3.2 ± 5.3° for the CTR and control groups, respectively (P = 0.613). Intraocular lens decentration and IOL tilt at 6 months were 0.29 ± 0.1 mm and 0.24 ± 0.1 mm and 6.7 ± 2.8° and 5.6 ± 1.6° for the CTR and control groups, respectively (P = 0.058; P < 0.01). A posterior IOL shift of 0.31 ± 0.31 mm and 0.19 ± 0.14 mm was observed in the CTR and control groups, respectively. Concomitant implantation of a CTR and a plate haptic IOL did not improve the overall rotational stability of the IOL compared with the control group. Against expectations, higher values of decentration, tilt, and axial shift were observed in the CTR group. The simultaneous use of a CTR and a plate haptic IOL in the absence of zonular weakness at the time of cataract surgery should be considered with caution. Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

20 September 2021 in Acta Ophthalmologica
Verified
Journal Article
Open access
PDF file
RMRupert Michael Menapace
Rupert Michael Menapace
DSDaniel Schartmüller
Daniel Schartmüller
VRVeronika Röggla
Veronika Röggla
GRGregor S. Reiter
Gregor S. Reiter
CLChristina Leydolt
Christina Leydolt
LSLuca Schwarzenbacher
Luca Schwarzenbacher
Purpose: The purpose of the study was to compare ultrasound (US) consumption and central macular thickness (CMT) and volume changes with manual and femtosecond laser (FSL)‐assisted cataract nucleus workup.Methods: Sixty patients scheduled for immediate sequential bilateral surgery underwent a prospective randomized intraindividual comparison of nucleus sector fragmentation performed manually in one eye and with low‐energy FSL assistance in the partner eye, followed by high‐fluidics phacoaspiration with a maximum US power of 30%. Ultrasound (US) energy consumption and macular thickness and volume were compared as measured by intraoperative effective phacoemulsification time (EPT) and high‐resolution spectral domain optical coherence tomography pre‐ and 1 week, 3 weeks and 6 weeks postoperatively. Results are presented as means ± SD or medians [min; max].Results: Fifty‐two patients completed the full follow‐up. For the manual and FSL‐assisted groups, nuclear hardness was almost identical with a mean LOCS III grade of 2.44 ± 1.08 and 2.50 ± 1.00 (p = 0.371). Median EPT was 1.40 [0.2; 8.3] and 1.25 [0.2; 9.4] seconds. Median preoperative CMT was 276.50 [263.25; 289.75] µm and 276.00 [262.00; 290.00] µm. Median postoperative CMT was 278.00 [260.50; 288.00] versus 275.50 [264.00; 290.50] µm at 1 week, 279.50 [266.75; 292.25] versus 280.00 [266.50; 294.50] µm at 3 weeks and 280.50 [268.00, 293.75] versus 279.50 [264.75; 295.25] µm at 6 weeks. Differences in CMT and total macular volume between the groups were not statistically significant at any point in time.Conclusion: Femtosecond laser (FSL) prefragmentation of the nucleus into six sectors did not reduce US energy consumption compared with manual splitting of the nucleus into four quadrants in this particular surgical setting. Sectorial FSL‐prechopping with the low‐energy FSL used had no additional impact on postoperative macular thickness and volume.

6 June 2024 in American Journal of Ophthalmology
Verified
Journal Article
Open access
VDVictor Danzinger
Victor Danzinger
DSDaniel Schartmüller
Daniel Schartmüller
MLMarcus Lisy
Marcus Lisy
MSMarkus Schranz
Markus Schranz
LSLuca Schwarzenbacher
Luca Schwarzenbacher
CLChristina Leydolt
Christina Leydolt
To compare intraindividual monocular visual performance of a monofocal extended depth-of-focus (EDOF) and a trifocal EDOF intraocular lens (IOL) following bilateral cataract surgery. Single-center, prospective, fellow-eye comparison clinical trial. All patients received uneventful bilateral cataract surgery with implantation of the monofocal EDOF Isopure IOL in the dominant eye and the trifocal EDOF FineVision Triumf IOL in the nondominant eye. Intraindividual monocular comparison included visual acuity at various distances, defocus curves, internal total higher-order aberration (HOA), spherical aberration (SA) Z(4.0), IOL decentration, and tilt. Additionally, subjective outcomes were evaluated using Halo and Glare simulation and the Seven-Item Visual-Functioning Index questionnaire. In total, 25 patients (50 eyes) were included. Intraindividual monocular best-corrected distance visual acuity, distance-corrected intermediate visual acuity, and best-corrected near visual acuity were comparable (P > .05). However, monocular contrast acuity (P = .019), distance-corrected near visual acuity (P < .001), and defocus curves at defocus levels of 0.0 D (P = .005) and between -1.5 and -4.0 D (P < .001) differed significantly. At 5 mm, internal HOA and SA Z(4.0) were significantly different (P < .001) and comparable at 3-mm pupil diameter, as were IOL tilt and decentration (P > .05). In this combined fellow-eye comparison, near vision was significantly better with the trifocal EDOF IOL. The monofocal EDOF IOL demonstrated similar distance and intermediate visual performance as the trifocal EDOF IOL. Overall, low values of photic phenomena and visual impairment were observed.