Piotr Korczyk

Dr. Piotr Korczyk


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2012 in Soft Matter
Verified
Journal Article
Closed access
PDF file
JGJan Guzowski
Jan Guzowski
PKPiotr Korczyk
Piotr Korczyk
Slawomir JakielaSlawomir Jakiela
Slawomir Jakiela
PGPiotr Garstecki
Piotr Garstecki
Microfluidic droplet-on-demand systems allow the controllable construction of multiple droplets of previously unattainable morphologies. Guided by the diagrams of the possible topologies of double droplets we investigate in detail the vistas to control the morphology of Janus droplets. We also explore and control new morphologies of multiple Janus droplets, i.e., arbitrarily long chains of alternating immiscible segments. Theoretical calculations together with the control offered by the use of automation allow the design of both the topology and the geometry (e.g. curvatures of the interfaces) of the multiple droplets. The ability to rationally design convex–convex, convex–concave and concave–convex segments may be useful in material science, while the ability to tune the distances between the interfaces in the chains of droplets may have applications in designing artificial biochemical signalling networks.

16 February 2010 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
KCKrzysztof Churski
Krzysztof Churski
PKPiotr Korczyk
Piotr Korczyk
PGPiotr Garstecki
Piotr Garstecki
We demonstrate a new droplet on demand (DOD) technique and an integrated system for scanning of arbitrary combinations of 3 miscible solutions in ∼1.5 μL droplets at 3 Hz. The DOD system uses standard electromagnetic valves that are external to the microfluidic chip. This feature makes up for modularity, simplicity of assembly and compatibility with virtually any microfluidic chip and yields an on-chip footprint of less than 1 mm2. A novel protocol for formation of DOD enables generation of an arbitrarily large range of volumes of droplets at a maximum operational frequency of ∼30 Hz. The integrated system that we demonstrate can be used to scan up to 10 000 conditions of chemical and biochemical reactions per hour using ∼10 mL of solutions in total.

15 October 2010 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
PKPiotr Korczyk
Piotr Korczyk
OCOlgierd Cybulski
Olgierd Cybulski
SMSylwia Makulska
Sylwia Makulska
PGPiotr Garstecki
Piotr Garstecki
Oscillations of the input rates of flow have a significant impact on the dynamics of formation of droplets in microfluidic systems and on the quality of generated emulsions.

9 September 2011 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
Slawomir JakielaSlawomir Jakiela
Slawomir Jakiela
SMSylwia Makulska
Sylwia Makulska
PKPiotr Korczyk
Piotr Korczyk
PGPiotr Garstecki
Piotr Garstecki
Droplet microfluidic techniques offer an attractive compromise between the throughput (of i.e. reactions per second) and the number of input/output controls needed to control them. Reduction of the number of controls follows from the confinement to essentially one-dimensional flow of slugs in channels which—in turn—relies heavily on the speed of flow of droplets. This speed is a complicated function of numerous parameters, including the volume of droplets (or length L of slugs), their viscosity μd, viscosity μc and rate of flow of the continuous phase, interfacial tension and geometry of the cross-section of the channel. Systematic screens of the impact of these parameters on the speed of droplets remain an open challenge. Here we detail an automated system that screens the speeds of individual droplets at a rate of up to 2000 experiments per hour, with high precision and without human intervention. The results of measurements in channels of square cross-section (of width w = 360 μm) for four different values of the contrast of viscosities λ = μd/μc = 0.3, 1, 3, and 33, wide ranges of values of the capillary number Ca ∈ (10−4, 10−1), and wide ranges of lengths of droplets l = L/w ∈ (0.8, 30) show that the speed of droplets depends significantly both on l and on λ. The dependence on Ca is very strong for λ > 1, while it is less important both for λ ≤ 1 and for λ ≫ 1.

7 June 2019 in Nature Communications
Verified
Journal Article
Open access
PDF file
PKPiotr Korczyk
Piotr Korczyk
VSVolkert van Steijn
Volkert van Steijn
SBSlawomir Blonski
Slawomir Blonski
DZDamian Zaremba
Damian Zaremba
DBDavid A. Beattie
David A. Beattie
PGPiotr Garstecki
Piotr Garstecki
While shear emulsification is a well understood industrial process, geometrical confinement in microfluidic systems introduces fascinating complexity, so far prohibiting complete understanding of droplet formation. The size of confined droplets is controlled by the ratio between shear and capillary forces when both are of the same order, in a regime known as jetting, while being surprisingly insensitive to this ratio when shear is orders of magnitude smaller than capillary forces, in a regime known as squeezing. Here, we reveal that further reduction of—already negligibly small—shear unexpectedly re-introduces the dependence of droplet size on shear/capillary-force ratio. For the first time we formally account for the flow around forming droplets, to predict and discover experimentally an additional regime—leaking. Our model predicts droplet size and characterizes the transitions from leaking into squeezing and from squeezing into jetting, unifying the description for confined droplet generation, and offering a practical guide for applications.

22 September 2022 in Blood Advances
Verified
Journal Article
Open access
PDF file
JRJulija Rabcuka
Julija Rabcuka
SBSlawomir Blonski
Slawomir Blonski
AMAthinoula Meli
Athinoula Meli
SSSamuel Sowemimo-Coker
Samuel Sowemimo-Coker
DZDamian Zaremba
Damian Zaremba
PSPawel Swietach
Pawel Swietach
Stored red blood cells (RBCs) incur biochemical and morphological changes, collectively termed the storage lesion. Functionally, the storage lesion manifests as slower oxygen unloading from RBCs, which may compromise the efficacy of transfusions where the clinical imperative is to rapidly boost oxygen delivery to tissues. Recent analysis of large real-world data linked longer storage with increased recipient mortality. Biochemical rejuvenation with a formulation of adenosine, inosine, and pyruvate can restore gas-handling properties, but its implementation is impractical for most clinical scenarios. We tested whether storage under hypoxia, previously shown to slow biochemical degradation, also preserves gas-handling properties of RBCs. A microfluidic chamber, designed to rapidly switch between oxygenated and anoxic superfusates, was used for single-cell oxygen saturation imaging on samples stored for up to 49 days. Aliquots were also analyzed flow cytometrically for side-scatter (a proposed proxy of O2 unloading kinetics), metabolomics, lipidomics, and redox proteomics. For benchmarking, units were biochemically rejuvenated at 4 weeks of standard storage. Hypoxic storage hastened O2 unloading in units stored to 35 days, an effect that correlated with side-scatter but was not linked to posttranslational modifications of hemoglobin. Although hypoxic storage and rejuvenation produced distinct biochemical changes, a subset of metabolites including pyruvate, sedoheptulose 1-phosphate, and 2/3 phospho-d-glycerate, was a common signature that correlated with changes in O2 unloading. Correlations between gas handling and lipidomic changes were modest. Thus, hypoxic storage of RBCs preserves key metabolic pathways and O2 exchange properties, thereby improving the functional quality of blood products and potentially influencing transfusion outcomes.