Wenming Wu

Dr. Wenming Wu

National Engineering Research Center for Health Care Devices, Guangdong Academy of Sciences, Guangzhou, China
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2018 in Advanced Healthcare Materials
Verified
Journal Article
Closed access
PDF file
JMJun Ma
Jun Ma
SYShiqiang Yan
Shiqiang Yan
CMChunyue Miao
Chunyue Miao
LLLinmei Li
Linmei Li
WSWeiwei Shi
Weiwei Shi
YAO LUYAO LU
YAO LU

1 August 2020 in Analytica Chimica Acta
Verified
Journal Article
Closed access
YJYangyang Jiang
Yangyang Jiang
AMAndreas Manz
Andreas Manz
Wenming WuWenming Wu
Wenming Wu

3 February 2020 in The Analyst
Verified
Journal Article
Closed access
PDF file
BSBing Shi
Bing Shi
YLYuanming Li
Yuanming Li
DWDi Wu
Di Wu
Wenming WuWenming Wu
Wenming Wu
The polymerase chain reaction (PCR) has unique advantages of sensitivity, specificity and rapidity in pathogen detection, which makes it at the forefront of academia and application in molecular biology diagnosis. In this study, we proposed a hand-held real-time fluorescence qPCR system, which can be used for the quantitative analysis of nucleic acid molecules. For the first time, we use a PVC microreactor which improved the transmittance of the microreactor and made it easy to collect the fluorescence signal. In order to make it portable, the system adopted a passive syringe for sample injection and integrated temperature control and detection with a lithium battery for power supply. What's more, the fluorescence signal was captured by using a smartphone through an external automatic robotic arm. This real-time qPCR system can detect genomic DNA of the H7N9 avian influenza over four orders of magnitude of concentration from 107 to 104 copies per μL. In addition, it was verified that the fluorescence images obtained by this system were clearer than those obtained by a traditional system (using a PTFE spatial PCR microreactor) with two typical dyes and a probe tested—EvaGreen, SYBR Green and FAM.

8 May 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
LHLimin He
Limin He
BSBenliang Sang
Benliang Sang
Wenming WuWenming Wu
Wenming Wu
The traditional qPCR instrument is bulky, expensive, and inconvenient to carry, so we report a portable rotary real-time fluorescent PCR (polymerase chain reaction) that completes the PCR amplification of DNA in the field, and the reaction can be observed in real-time. Through the analysis of a target gene, namely pGEM-3Zf (+), the gradient amplification and melting curves are compared to commercial devices. The results confirm the stability of our device. This is the first use of a mechanical rotary structure to achieve gradient amplification curves and melting curves comparable to commercial instruments. The average power consumption of our system is about 7.6 W, which is the lowest energy consumption for real-time fluorescence quantification in shunting PCR and enables the use of our device in the field thanks to its self-contained power supply based on a lithium battery. In addition, all of the equipment costs only about 710 dollars, which is far lower than the cost of a commercial PCR instrument because the control system through mechanical displacement replaces the traditional TEC (thermoelectric cooler) temperature control. Moreover, the equipment has a low technical barrier, which can suit the needs of non-professional settings, with strong repeatability.

3 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
DWDi Wu
Di Wu
Wenming WuWenming Wu
Wenming Wu
Temperature control is the most important and fundamental part of a polymerase chain reaction (PCR). To date, there have been several methods to realize the periodic heating and cooling of the thermal-cycler system for continuous-flow PCR reactions, and three of them were widely used: the thermo-cycled thermoelectric cooler (TEC), the heating block, and the thermostatic heater. In the present study, a new approach called open-loop controlled single thermostatic TEC was introduced to control the thermal cycle during the amplification process. Differing from the former three methods, the size of this microdevice is much smaller, especially when compared to the microdevice used in the heating block method. Furthermore, the rising and cooling speed of this method is much rapider than that in a traditional TEC cycler, and is nearly 20–30% faster than a single thermostatic heater. Thus, a portable PCR system was made without any external heat source, and only a Teflon tube-wrapped TEC chip was used to achieve the continuous-flow PCR reactions. This provides an efficient way to reduce the size of the system and simplify it. In addition, through further experiments, the microdevice is not only found to be capable of amplification of a PCR product from Human papillomavirus type 49 (Genbank ref: X74480.1) and Rubella virus (RUBV), but also enables clinical diagnostics, such as a test for hepatitis B virus.