Jin Xi

Dr. Jin Xi


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
CXChanghang XU
Changhang XU
JXJin Xi
Jin Xi
CWChangwei Wu
Changwei Wu
LGLemei Gao
Lemei Gao
GCGuoming Chen
Guoming Chen
Gangbing SongGangbing Song
Gangbing Song
The effectiveness of pulsed thermography (PT) for detecting delamination in carbon fiber-reinforced polymer (CFRP) plates has been widely verified. However, delaminations are usually characterized by weak visibility due to the influences of inspection factors and the delaminations with weak visibility are easily missed in real inspections. In this study, by introducing a deep learning algorithm—stacked autoencoder (SAE)—to PT, we propose a novel approach (SAE-PT) to enhance the visibility of delaminations. Based on the ability of SAE to learn unsupervised features from data, the thermal features of delaminations are extracted from the raw thermograms. The extracted features are then employed to construct SAE images, in which the visibility of delaminations is expected to be enhanced. To test the performance of SAE-PT, we inspected CFRP plates with prefabricated delaminations. By implementing SAE-PT on the raw inspection data, the delaminations were more clearly indicated in the constructed SAE images. We also compare SAE-PT to the widely used principal component thermography (PCT) method to further verify the validity of the proposed approach. The results reveal that compared to PCT, SAE-PT can show delaminations in CFRP with higher contrast. By effectively enhancing the delamination visibility, SAE-PT thus has potential for improving the inspection accuracy of PT for non-destructive testing (NDT) of CFRP.

23 November 2017 in Sensors
Verified
Journal Article
Open access
PDF file
CXChanghang XU
Changhang XU
JXJin Xi
Jin Xi
ZWZhang Wuyang
Zhang Wuyang
Qingzhao KongQingzhao Kong
Qingzhao Kong
GCGuoming Chen
Guoming Chen
Gangbing SongGangbing Song
Gangbing Song
Vibrothermography often employs a high-power actuator to generate heat on a specimen to reveal damage, however, the high-power actuator brings inconvenience to the application and possibly introduces additional damage to the inspected objects. This study uses a low-power piezoceramic transducer as the actuator of vibrothermography and explores its ability to detect multiple surface cracks in a metal part. Experiments were conducted on a thin aluminum beam with three cracks in different orientations. Detailed analyses of both thermograms and temperature data are presented to validate the proposed vibrothermography method. To further investigate the performance of the proposed vibrothermography method, we experimentally studied the effects of several critical factors, including the amplitude of excitation signal, specimen constraints, relative position between the transducer and cracks (the transducer is mounted on the same or the opposite side with the cracks). The results demonstrate that all cracks can be detected conveniently and simultaneously by using the proposed low-power vibrothermography. We also found that the magnitude of excitation signal and the specimen constraints have a great influence on detection results. Combined with effective data processing methods, such as Fourier transformation employed in this study, the proposed method provides a promising potential to detect multiple cracks on a metal surface in a safe and effective manner.

17 November 2024 in International Journal of Pressure Vessels and Piping
Verified
Journal Article
Open access
JXJin Xi
Jin Xi
WWWenao Wang
Wenao Wang
CXChanghang Xu
Changhang Xu
MFMingfu Fu
Mingfu Fu
WHWeiping Huang
Weiping Huang

5 December 2016 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JXJin Xi
Jin Xi
CXChanghang XU
Changhang XU
XGXumei Gong
Xumei Gong
WHWeiping Huang
Weiping Huang
GCGuoming Chen
Guoming Chen
We developed a new approach for sizing subsurface defects in the square pulse thermography of metallic plates by employing the oriented gradient of histograms. To size defects with high accuracies is still a challenge in infrared (IR) thermography today. Especially for blurry defects, accurate sizing of them is difficult with existing methods. The oriented gradient of histograms, which is used in the successful probability of boundary (Pb) contour detector in natural image processing literature, is employed in this work to improve the sizing accuracy in square pulse thermography. Experiments on a corroded steel plate with flat blind holes have verified the effectiveness of the proposed approach to size defects. Experimental results show that the proposed approach can size distinct and blurry defects with high accuracies. Comparison research is also implemented between the proposed approach and other sizing methods. The comparison results show that the proposed approach is superior to existing methods.