Introduction: Traditional intermittent hypoxia training improves sport performance after short periods of exposure, but acute exposure to intermittent hypoxia leads to decreased training intensity and technical quality. The solution to overcome these negative effects may be to perform efforts in normoxia and the intervals between efforts in hypoxia, maintaining the quality of training and the benefits of hypoxia. Objective: This study aimed to evaluate the acute physiological responses to hypoxia exposure during recovery between high intensity efforts. Materials and methods: Randomized, one-blind, placebo-controlled study. Sixteen men performed a graded exercise test to determine their maximal intensity and two sessions of high-intensity interval training. The training intervals could be in hypoxia (HRT), FIO2: 0.136 or normoxia (NRT), FIO2: 0.209. During the two-minute interval between the ten one-minute efforts, peripheral oxygen saturation (SpO2), heart rate (HR), blood lactate ([La]), blood glucose ([Glu]) were constantly measured. Results: There were differences in HR (TRN = 120 ± 14 bpm; TRH = 129 ± 13 bpm, p < 0.01) and SpO2 (TRN = 96.9 ± 1.0%; TRH = 86.2 ± 3.5%, p < 0.01). No differences in [La] and [Glu] TRN (4.4 ± 1.7 mmol.l-1; 3.9 ± 0.5 mmol.l-1) and TRH (5.2 ± 2.0 mmol.l-1; 4.0 ± 0.8 mmol.l-1, p = 0.17). Conclusion: The possibility of including hypoxia only in the recovery intervals as an additional stimulus to the training, without decreasing the quality of the training, was evidenced. Level of Evidence II; Randomized Clinical Trial of Minor Quality.
Introduction. This study aimed to compare the results of professional technical and anthropometric anamnesis data with the transmission of external chest compressions performed by military firefighters at different execution times. Objective. The objective was to evaluate the performance and perceived effort of the sequence of external chest compressions performed in two minutes, as well as the evolution of the technique over time. Materials and Methods. This was a descriptive, correlational study involving adult firefighters who were members of a specific firefighter group, comprising a population of 105 individuals with a voluntary sample of 44 participants. The study used a Bayesian statistical approach to provide probabilistic expressions. Results. The participants had an average work experience of 17years, an average age of 38.6years, an average weight of 81.48kilograms, an average height of 176centimeters, and an average of 2.5 qualifications. The results indicated that the firefighters performed external chest compressions with excellent technique and a moderate level of perceived effort in a two-minute evaluation. The evaluation of the evolution of the technique over time showed that the participants were able to maintain high-quality compressions for an average of 6minutes, with a maximum of 20 uninterrupted minutes. Conclusion. The study underscores the critical role of professional firefighters in performing and maintaining high-quality external chest compressions, which has the potential to reduce morbidity and mortality in cases of cardiorespiratory arrest.
2 October 2021 in Research Quarterly for Exercise and Sport
Purpose: Judo is an intermittent sport, dependent on anaerobic metabolism as well as aerobic metabolism to generate energy during a match; however, there are few reliable tests to measure specific aerobic performance in judo. Thus, the present study aimed to propose a new specific and indirect method to assess the aerobic performance in judo athletes; it determined the inter-rater and test–retest reliability of this new protocol and correlated the new protocol with a valid laboratory test. Method: The participants included 15 men, athletes of judo (age average: 21.59 ± 4.60 years, weight: 80.71 ± 15.93 kg and height: 173.2 ± 6.84 cm). The participants performed three tests: the first test was a graded exercise test (GXT) and the second and third tests were the Judo Aerobic Test (JAT). Results: The test presented high test–retest and inter-rater reliability, the intraclass correlation coefficients (ICC) ranking of 0.68–0.96, the correlation values ranging from .77 to .96, and no statistical differences between means in test and retest (p > .05). The standard error of measurement and the coefficient of variation between raters presented lower than 10%, indicating reproducibility. Moderate and strong correlations were found between JAT and GXT variables. Conclusion: We concluded that the test presents excellent inter-rater and test–retest reliability and a moderate correlation with GXT.
As doenças cardiovasculares são o principal motivo de mortes no mundo e apesar dos avanços na atualidade com relação ao tratamento e à prevenção, a parada cardiorrespiratória é um grande problema de saúde pública mundial. O atendimento adequado da parada cardiorrespiratória exige organização, decisão rápida, assertiva e habilidades por parte dos envolvidos no atendimento, dessa forma é fundamental que os profissionais mantenham constante treinamento e métodos de reavaliação de suas habilidades. O objetivo desse estudo foi analisar a efetividade das compressões torácicas externas realizadas por bombeiros, com tempo de execução de dois minutos, em treinamento durante a pandemia Covid-19. Trata-se de um estudo descritivo, correlacional, realizado de janeiro à novembro de 2020, no Corpo de Bombeiros de Ribeirão Preto, com participantes adultos, bombeiros militares, pertencentes a um Grupamento específico, compondo amostra de 44 voluntários. O estudo abordou o convite aos participantes e sua caracterização bem como pré-teste de análise de efetividade das compressões torácicas externas por dois minutos, após ocorreu aula expositiva de aproximadamente quinze minutos sobre ressuscitação cardiopulmonar e treinamento de habilidades para compressões torácicas externas. Após o treinamento ocorreu teste de efetividade das compressões torácicas externas por dois minutos. Para análise estatística foi utilizado abordagem bayesiana foi utilizada para fornecer afirmações probabilísticas. Através das ferramentas metodológicas para análise da efetividade das compressões torácicas observou-se alta acurácia científica e nos resultados identificou-se um ótimo desempenho dos bombeiros, tanto no pré-teste como nos pós teste, além da percepção moderada de esforço nas compressões.