Gerard JH Hutten

Gerard JH Hutten

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2024 in The Lancet Regional Health - Europe
Verified
Journal Article
Open access
RKRonny Knol
Ronny Knol
EBEmma Brouwer
Emma Brouwer
TAThomas van Den Akker
Thomas van Den Akker
PDPhilip L.J. DeKoninck
Philip L.J. DeKoninck
WOWes Onland
Wes Onland
APArjan B. Te Pas
Arjan B. Te Pas
Physiological-based cord clamping (PBCC) in preterm infants is beneficial for cardiovascular transition at birth and may optimize placental transfusion. Whether PBCC can improve clinical outcomes is unknown. The aim of the Aeration, Breathing, Clamping (ABC3) trial was to test whether PBCC results in improved intact survival in very preterm infants. The ABC3 trial was a parallel-group, multicentre, randomised, controlled superiority clinical trial conducted in all Dutch tertiary referral centers for perinatal care involving infants born before 30 weeks of gestation. Infants were randomised to either PBCC or time-based delayed cord clamping (TBCC), stratified by gestational age and treatment center. Infants receiving PBCC were stabilised with umbilical cord intact, which was clamped after reaching cardiorespiratory stability (heart rate >100 bpm and SpO2 >85% while supplemental oxygen <40%). In TBCC the cord was clamped after 30–60 s. The primary outcome was survival without major cerebral injury and/or necrotizing enterocolitis. The primary and key secondary analyses were done in both the intention-to-treat and per-protocol populations. The trial was registered with ClinicalTrials.gov (NCT03808051). From January 25, 2019, through October 2, 2022, 669 infants were randomised (median gestational age 27+5 weeks (IQR 26+2–28+6)) and included in the intention-to-treat population. Intact survival occurred in 241 of 339 infants (71.1%) after PBCC, compared with 223 of 330 (67.6%) after TBCC (odds ratio 1.18, 95% CI 0.84–1.66; absolute risk difference 3.1 %points, 95% CI −11.0 to 15.8, p = 0.33). Pre-specified subgroup analysis showed 69.9% intact survival in male infants after PBCC, compared with 61.8% after TBCC (odds ratio 2.32, 95% CI 1.42–3.78, p for interaction 0.026). Secondary outcomes showed fewer red blood cell transfusions after PBCC (rate ratio 0.83, 95% CI 0.75–0.92, p = 0.0003), lower incidence of late-onset sepsis (27.4% versus 33.3%, odds ratio 0.77, 95% CI 0.62–0.95, p = 0.013) and lower admission temperature (36.3 °C versus 36.7 °C, mean difference −0.5, 95% CI −0.8 to −0.3, p < 0.0001). Parents were less anxious (Likert scale 1.52 (SD 0.97) versus 2.23 (SD 1.35); p < 0.001) and more content (Likert scale 4.74 (SD 0.75) versus 4.49 (SD 0.97); p < 0.001) after PBCC. PBCC in very preterm infants did not increase survival without major cerebral injury or necrotizing enterocolitis compared to TBCC in the entire cohort. A possible beneficial effect in male infants requires confirmation from other trials. PBCC was safe to perform and parents reported more contentment and less anxiety. The Netherlands Organization for Health Research and Development.

1 February 2021 in Pediatric Pulmonology
Verified
Journal Article
Open access
PDF file
RLRuud W. van Leuteren
Ruud W. van Leuteren
CWCornelia G. de Waal
Cornelia G. de Waal
GHGerard JH Hutten
Gerard JH Hutten
FJFrans H. de Jongh
Frans H. de Jongh
AKAnton H. van Kaam
Anton H. van Kaam
Objective: Monitoring work of breathing (WOB) is important to assess the pulmonary condition and adjust respiratory support in preterm infants. Conventional WOB measurement (esophageal pressure, tidal volume) is invasive and we hypothesized that monitoring diaphragm activity could be a noninvasive alternative to estimate WOB. The objective was to determine the correlation between conventional WOB measures and diaphragm activity, in preterm infants.Methods: WOB and diaphragm activity, measured with transcutaneous electromyography (dEMG), were simultaneously recorded at different nasal continuous positive airway pressure (nCPAP) levels. During a 30‐s recording at each nCPAP level, dEMG parameters, inspiratory WOB (WOBi), and pressure time product (PTPin) were calculated per breath. The correlation coefficient between WOB‐ and dEMG‐measures was calculated using single breaths and after aggregating all breaths into deciles of incremental WOBi.Results: Fifteen preterm infants were included (median gestational age, 28 weeks). Single‐breath analysis showed a poor median correlation of 0.27 (interquartile range [IQR], 0.03 to 0.33) and 0.08 (IQR, −0.03 to 0.28), respectively, for WOBi and PTPin with peak diaphragmatic activity (dEMGpeak). A modest median correlation coefficient of 0.65 (IQR, 0.13 to 0.79) and 0.43 (IQR, −0.33 to 0.69) was found for, respectively, WOBi and PTPin with dEMGpeak in the aggregated analysis.Conclusion: Diaphragm activity showed a modest correlation with WOBi and PTPin in an aggregated analysis. This finding warrants further studies in infants with more significant lung disease.

25 May 2022 in Physiological Measurement
Verified
Journal Article
Closed access
ASAnouk W J Scholten
Anouk W J Scholten
RLRuud W van Leuteren
Ruud W van Leuteren
CWCornelia G de Waal
Cornelia G de Waal
FJFrans H de Jongh
Frans H de Jongh
AKAnton H van Kaam
Anton H van Kaam
GHGerard JH Hutten
Gerard JH Hutten
Objective. Monitoring heart rate (HR) and respiratory rate (RR) is essential in preterm infants and is currently measured with ECG and chest impedance (CI), respectively. However, in current clinical practice these techniques use wired adhesive electrodes which can cause skin damage and hinder parent-infant interaction. Moreover, CI is not always reliable. We assessed the feasibility of a wireless dry electrode belt to measure HR and RR via transcutaneous diaphragmatic electromyography (dEMG). Approach. In this prospective, observational study, infants were monitored up to 72 h with the belt and standard CI. Feasibility of the belt was expressed by its ability to retrieve a respiratory waveform from dEMG, determining the percentage of time with stable respiration data without signal errors (‘lead-off’ and Bluetooth Loss Error, ‘BLE’), skin-friendliness of the belt (skin score) and by exploring the ability to monitor trends in HR and RR with the belt. Main results. In all 19 included infants (median gestational age 27.3 weeks) a respiratory waveform could be obtained. The amount of signal errors was low (lead-off 0.5% (IQR 0.1–1.6) and BLE 0.3% (IQR 0.1–0.9)) and 76.5% (IQR 69.3–80.0) of the respiration measurement was stable. No adverse skin effects were observed (median skin score of 3(3–4)). A similar HR and RR trend between the belt and CI was observed. Significance. Dry electrodes incorporated in a non-adhesive belt can measure dEMG in preterm infants. The belt provided a HR and RR trend similar to CI. Future studies are required to investigate the non-inferiority of the belt as a cardiorespiratory monitor compared to CI.

5 October 2023 in Pediatric Pulmonology
Verified
Journal Article
Open access
ASAnouk W. J. Scholten
Anouk W. J. Scholten
ZZZhuozhao Zhan
Zhuozhao Zhan
HNHendrik Niemarkt
Hendrik Niemarkt
MVMarieke Vervoorn
Marieke Vervoorn
RLRuud W. van Leuteren
Ruud W. van Leuteren
GHGerard JH Hutten
Gerard JH Hutten
Introduction: We determined if the heart rate (HR) monitoring performance of a wireless and nonadhesive belt is non‐inferior compared to standard electrocardiography (ECG). Secondary objective was to explore the belt's respiratory rate (RR) monitoring performance compared to chest impedance (CI).Method: In this multicenter non‐inferiority trial, preterm and term infants were simultaneously monitored with the belt and conventional ECG/CI for 24 h. HR monitoring performance was estimated with the HR difference and ability to detect cardiac events compared to the ECG, and the incidence of HR‐data loss per second. These estimations were statistically compared to prespecified margins to confirm equivalence/non‐inferiority. Exploratory RR analyses estimated the RR trend difference and ability to detect apnea/tachypnea compared to CI, and the incidence of RR‐data loss per second.Results: Thirty‐nine infants were included. HR monitoring with the belt was non‐inferior to the ECG with a mean HR difference of 0.03 beats per minute (bpm) (standard error [SE] = 0.02) (95% limits of agreement [LoA]: [−5 to 5] bpm) (p < 0.001). Second, sensitivity and positive predictive value (PPV) for cardiac event detection were 94.0% (SE = 0.5%) and 92.6% (SE = 0.6%), respectively (p ≤ 0.001). Third, the incidence of HR‐data loss was 2.1% (SE = 0.4%) per second (p < 0.05). The exploratory analyses of RR showed moderate trend agreement with a mean RR‐difference of 3.7 breaths/min (SE = 0.8) (LoA: [−12 to 19] breaths/min), but low sensitivities and PPV's for apnea/tachypnea detection. The incidence of RR‐data loss was 2.2% (SE = 0.4%) per second.Conclusion: The nonadhesive, wireless belt showed non‐inferior HR monitoring and a moderate agreement in RR trend compared to ECG/CI. Future research on apnea/tachypnea detection is required.

25 November 2019 in Pediatric Pulmonology
Verified
Journal Article
Open access
PDF file
RLRuud W. van Leuteren
Ruud W. van Leuteren
RBRobin E. Bekhuis
Robin E. Bekhuis
CWCornelia G. de Waal
Cornelia G. de Waal
FJFrans H. de Jongh
Frans H. de Jongh
AKAnton H. van Kaam
Anton H. van Kaam
GHGerard JH Hutten
Gerard JH Hutten
Objective: To determine the effect of changing electrode positions on vital signs and respiratory effort parameters measured with transcutaneous electromyography of the diaphragm (dEMG) in preterm infants.Methods: In this observational study, simultaneous dEMG measurements were performed at the standard position and at one alternative electrode position (randomly assigned to lateral, superior, medial, inferior to the standard placement, or dorsal). The activity of the diaphragm was measured for 1 hour at both positions. Main outcome measures were the agreement in heart rate (HR), respiratory rate (RR), and percentage difference in dEMG parameters of respiratory effort (peak and tonic activity, amplitude, area under the curve, and frequency content) between the standard and alternative electrode positions.Results: Thirty clinically stable preterm infants (gestational age 30.1 ± 3.0 weeks) with either no or noninvasive respiratory support were included. Agreement in HR was excellent at all positions (ICC > 0.95) while RR agreement showed more diversity (ICC range 0.40‐0.86). Mixed modeling of dEMG parameters revealed that medial and inferior placement measured the weakest signals (median 75.5% and 64.5% lower dEMG amplitude). Lateral electrode placement showed the highest similarity to standard positioning (median 23.5% lower amplitude).Conclusion: Measuring HR showed high similarity at all positions. However, registration of RR and respiratory effort is clearly influenced by the electrode position. Electrodes in the same transversal plane as the diaphragm, and at sufficient distance from each other, provide the best agreement with the standard positioning.

1 January 2023 in Physiological Measurement
Verified
Journal Article
Open access
RPRosemijne R W P Pigmans
Rosemijne R W P Pigmans
RLRuud W van Leuteren
Ruud W van Leuteren
ASAnouk W J Scholten
Anouk W J Scholten
CVChiara Veneroni
Chiara Veneroni
AKAnton H van Kaam
Anton H van Kaam
FJFrans H C de Jongh
Frans H C de Jongh
Objective. To examine the influence of the endotracheal tube (ETT) on respiratory reactance (X rs ) measured with the forced oscillation technique (FOT) and develop a correction method for it. Approach. In a bench study, the reactance of ETTs (X tube ) with different dimensions was measured on a breathing test lung in various respiratory settings. Main results. X tube can be accurately predicted by a fitted formula, with an R 2 of 0.97, with negligible effects due to changes in respiratory pattern and lung volume. Significance. The developed formula offers the ability to measure ETT-independent X rs values of patients, improving the potential of FOT for lung function testing in mechanically ventilated newborns.