Jinglun Li

Dr. Jinglun Li


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JZJipeng Zhang
Jipeng Zhang
XXXiong Xiao
Xiong Xiao
YCYe Chen
Ye Chen
BZBin Zhang
Bin Zhang
XMXinhua Ma
Xinhua Ma
JLJinglun Li
Jinglun Li
(1) Background: The imaging energy range of a typical Compton camera is limited due to the fact that scattered gamma photons are seldom fully absorbed when the incident energies are above 3 MeV. Further improving the upper energy limit of gamma-ray imaging has important application significance in the active interrogation of special nuclear materials and chemical warfare agents, as well as range verification of proton therapy. (2) Methods: To realize gamma-ray imaging in a wide energy range of 0.3~7 MeV, a principle prototype, named a portable three-layer Compton camera, is developed using the scintillation detector that consists of an silicon photomultiplier array coupled with a Gd3Al2Ga3O12:Ce pixelated scintillator array. Implemented in a list-mode maximum likelihood expectation maximization algorithm, a far-field energy-domain imaging method based on the two interaction events is applied to estimate the initial energy and spatial distribution of gamma-ray sources. The simulation model of the detectors is established based on the Monte Carlo simulation toolkit Geant4. The reconstructed images of a 133Ba, a 137Cs and a 60Co point-like sources have been successfully obtained with our prototype in laboratory tests and compared with simulation studies. (3) Results: The proportion of effective imaging events accounts for about 2%, which allows our prototype to realize the reconstruction of the distribution of a 0.05 μSv/h 137Cs source in 10 s. The angular resolution for resolving two 137Cs point-like sources is 15°. Additional simulated imaging of the 6.13 MeV gamma-rays from 14.1 MeV neutron scattering with water preliminarily demonstrates the imaging capability for high incident energy. (4) Conclusions: We conclude that the prototype has a good imaging performance in a wide energy range (0.3~7 MeV), which shows potential in several MeV gamma-ray imaging applications.

18 March 2024 in Energies
Verified
Journal Article
Open access
PDF file
WLWenhui Li
Wenhui Li
QZQianqian Zhou
Qianqian Zhou
YZYuzhong Zhang
Yuzhong Zhang
JXJianming Xie
Jianming Xie
WZWei Zhao
Wei Zhao
HCHui Cui
Hui Cui
(1) Background: Generally, in nuclear medicine and nuclear power plants, energy spectrum measurements and radioactive nuclide identification are required for evaluation of strong radiation fields to ensure nuclear safety and security; thereby, damage is prevented to nuclear facilities caused by natural disasters or the criminal smuggling of nuclear materials. High count rates can lead to signal accumulation, negatively affecting the performance of gamma spectrometers, and in severe cases, even damaging the detectors. Higher pulse throughput with better energy resolution is the ultimate goal of a gamma-ray spectrometer. Traditionally, pileup pulses, which cause dead time and affect throughput, are rejected to maintain good energy resolution. (2) Method: In this paper, an ultra-throughput boost (UTB) off-line processing method was used to improve the throughput and reduce the pileup effect of the spectrometer. Firstly, by fitting the impulse signal of the detector, the response matrix was built by the functional model of a dual exponential tail convolved with the Gaussian kernel; then, a quadratic programming method based on a non-negative least squares (NNLS) algorithm was adopted to solve the constrained optimization problem for the inversion. (3) Results: Both the simulated and experimental results of the UTB method show that most of the impulses in the pulse sequence from the scintillator detector were restored to δ-like pulses, and the throughput of the UTB method for the NaI(Tl) spectrometer reached 207 kcps with a resolution of 7.71% @661.7 keV. A reduction was also seen in the high energy pileup phenomenon. (4) Conclusions: We conclude that the UTB method can restore individual and piled-up pulses to δ-like sequences, effectively boosting pulse throughput and suppressing high-energy tailing and sum peaks caused by the pileup effect at the cost of a slight loss in energy resolution.

1 October 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YJYubin Jia
Yubin Jia
YJYiyang Jiang
Yiyang Jiang
WLWenhui Li
Wenhui Li
ZWZhuoqun Wang
Zhuoqun Wang
SLShuaibin Liu
Shuaibin Liu
JLJinglun Li
Jinglun Li
Accurate radionuclide identification is critical for nuclear safety and environmental radiation monitoring. To integrate the guiding effect of peak morphology features and the nonlinear fitting capability of data-driven models, this paper proposes a Physics-Enhanced Module (PEM). This module adopts the Laplacian of Gaussian (LoG) operator to decompose input gamma spectra and generate auxiliary features representing peak responses, which are concatenated with the original spectrum as an additional channel to inject peak position information into neural networks. Small-sample comparative experiments are conducted on a multi-label nuclide identification dataset covering 16 radionuclides, where PEM-ResNet and PEM-DenseNet are compared against vanilla ResNet and DenseNet baseline models. Experimental results demonstrate that all physics-enhanced networks outperform their corresponding baselines across all evaluation metrics. Consistent performance improvements observed on two mainstream convolutional architectures verify that the PEM effectively mitigates performance degradation induced by limited training samples. Further analysis reveals that the PEM provides the model with clearly identifiable peak response features for discrimination tasks. The integrated framework synergizes the fitting strengths of data-driven learning and the regularization merits of the fixed preprocessing module, thereby substantially improving the reliability and robustness of nuclide identification for nuclear energy applications.