Samuel Bunani

Prof. Dr. Samuel Bunani

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Desalination
Verified
Journal Article
Closed access
DIDeniz İpEkçi
Deniz İpEkçi
NKNalan Kabay
Nalan Kabay
SBSamuel Bunani
Samuel Bunani
Esra AltıokEsra Altıok
Esra Altıok
MAMüşerref Arda
Müşerref Arda
SNSyouhei Nishihama
Syouhei Nishihama

1 December 2018 in Desalination
Verified
Journal Article
Closed access
DIDeniz İpEkçi
Deniz İpEkçi
Esra AltıokEsra Altıok
Esra Altıok
SBSamuel Bunani
Samuel Bunani
KYKazuharu Yoshizuka
Kazuharu Yoshizuka
SNSyouhei Nishihama
Syouhei Nishihama
NKNalan Kabay
Nalan Kabay

12 April 2024 in Molecules
Verified
Journal Article
Open access
PDF file
SBSamuel Bunani
Samuel Bunani
GAGudrun Abbt-Braun
Gudrun Abbt-Braun
HHHarald Horn
Harald Horn
Lack of safe water availability and access to clean water cause a higher risk of infectious diseases and other diseases as well. Heavy metals (HMs) are inorganic pollutants that cause severe threats to humans, animals, and the environment. Therefore, an effective HM removal technology is urgently needed. In the present study, a customized bipolar membrane electrodialysis process was used to remove HMs from aqueous solutions. The impacts of the feed ionic strength, applied electrical potential, and the type and concentration of HMs (Cd2+, Co2+, Cr3+, Cu2+, and Ni2+) on the process performance were investigated. The results showed that feed solution pH changes occurred in four stages: it first decreased linearly before stabilizing in the acidic pH range, followed by an increase and stabilization in the basic range of the pH scale. HM speciation in the basic pH range revealed the presence of anionic HM species. The presence of HMs on anion exchange membranes confirmed the contribution of these membranes for HM removal in the base channels of the process. While no clear trend was seen in the ionic strength solution, the maximum HM removal was observed when 1.5 g/L NaCl was used. The initial HM concentration showed a linear increase in HMs removal of up to 30 mg/L. A similar trend was seen with an increase in the applied electrical potential of up to 15 V. In general, the amount of HMs removed increased in the following order: Cd2+ ˃ Ni2+ ˃ Co2+ ˃ Cu2+ ˃ Cr3+. Under some operational conditions, however, the removed amount of Cu2+, Co2+, and Ni2+ was similar. The mass balance and SEM-EDX results revealed that the removed HMs were sorbed onto the membranes. In conclusion, this process efficiently separates HMs from aqueous solutions. It showed the features of diluate pH adjustment, reduction in the overall stack electrical resistance, and contribution of anion exchange membranes in multivalent cation removal. The mechanisms involved in HMs removal were diffusion and migration from the bulk solution, followed by their sorption on both cation and anion exchange membranes.

19 February 2015 in Environmental Science and Pollution Research
Verified
Journal Article
Closed access
PDF file
SBSamuel Bunani
Samuel Bunani
EYEren Yörükoğlu
Eren Yörükoğlu
GSGökhan Sert
Gökhan Sert
NKNALAN KABAY
NALAN KABAY
ÜYÜmran Yüksel
Ümran Yüksel
TPTaylan Özgür Pek
Taylan Özgür Pek

9 September 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
SNStanislas Ndayishimiye
Stanislas Ndayishimiye
SBSamuel Bunani
Samuel Bunani
ENEmery Nkurunziza
Emery Nkurunziza
NKNALAN KABAY
NALAN KABAY
The increasing generation of liquid waste from agricultural, industrial, and municipal sources poses significant environmental challenges due to its high content of organic carbon (OC) and nutrients such as phosphorus and nitrogen. This review examined the effectiveness of membrane-based technologies, particularly microfiltration (MF) and ultrafiltration (UF), in separating and recovering these valuable compounds. Drawing on key literature indexed in Scopus, the review analyzed how membrane properties, operating conditions, and feed characteristics influence removal efficiency. The find-ings indicate that MF membranes primarily retain particulate organic matter and sus-pended solids (SS), with limited retention of phosphorus and nitrogen species. In con-trast, UF membranes exhibited superior performance in removing both OC and phos-phorus, and partially retain some nitrogen compounds depending on molecular size and charge. When combined with pre-treatment processes such as coagulation or ad-sorption, both MF and UF achieve higher nutrient removal rates. These membrane technologies showed promise not only in reducing pollutant loads but also in enabling nutrient recovery for potential reuse in agriculture. The optimization of membrane configuration and integration with other processes is essential for enhancing treatment performance and contributing to circular wastewater management strategies.

27 October 2026 in Membranes
Verified
Journal Article
Open access
PDF file
Emery NKURUNZIZAEmery NKURUNZIZA
Emery NKURUNZIZA
SBSamuel Bunani
Samuel Bunani
SNStanislas Ndayishimiye
Stanislas Ndayishimiye
NKNALAN KABAY
NALAN KABAY
Bipolar membrane electrodialysis (BMED) is an electro-membrane separation technology used for over 20 years to treat liquid wastes, including wastewater from various industrial processes, municipal wastewater, and animal farms. This technology has been developed for its ability to dissociate H2O into H+ and OH− ions and to convert cations and anions in the feed solution into bases and acids, respectively, by applying an electrical potential. In comparison with alternative treatment technologies, BMED has some advantages, such as no need for chemical reagents, high degrees of efficiency, and straightforward operational procedures. However, BMED has been limited by a high level of preparation expense for BMs, membrane deposition, and ion loss during operation. This review mainly describes the principles and designs of BMED, their compositions along with their advantages and disadvantages, the membrane fouling and cleaning, and also the trend of their application in wastewater treatment. Finally, the results on nutrient recovery by BMED show that the performance of BMED depends on the nature of the ion exchange membranes used, the composition of the sample solution, the process conditions, and the configuration of the membrane stack.