Eduardo Miqueles

Dr. Eduardo Miqueles

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2014 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
EMEduardo Miqueles
Eduardo Miqueles
JRJ. Rinkel
J. Rinkel
FOF. O'DOwd
F. O'DOwd
JBJ. S. V. Bermúdez
J. S. V. Bermúdez

20 January 2010 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
EMEduardo Miqueles
Eduardo Miqueles
APAlvaro R De Pierro
Alvaro R De Pierro
X-ray fluorescence computed tomography (XFCT) is a relatively new synchrotron-based imaging modality aiming at reconstructing the distribution of nonradiative elements within a sample irradiated with high-intensity monochromatic x-rays. In a recent paper La Riviere (2004 Phys. Med. Biol. 49 2391-405) presented an approximated inversion method based on reducing the problem to the inversion of the exponential radon transform. In this paper we compare La Riviere's results with recently derived 'exact' analytic formulae for the generalized attenuated radon transform. We present numerical experiments with real and simulated data.

26 October 2017 in IEEE Transactions on Image Processing
Verified
Journal Article
Closed access
EMEduardo Miqueles
Eduardo Miqueles
NKNikolay Koshev
Nikolay Koshev
EHElias S. Helou
Elias S. Helou
Fast image reconstruction techniques are becoming important with the increasing number of scientific cases in high resolution micro and nano tomography. The processing of the large scale 3D data demands new mathematical tools for the tomographic reconstruction. Due to the high computational complexity of most current algorithms, big data sizes demands powerful hardware and more sophisticated numerical techniques. Several reconstruction algorithms are dependent on a mathematical tool called backprojection (a transposition process). A conventional implementation of the backprojection operator has cubic computational complexity. In the present manuscript we propose a new fast backprojection operator for the processing of tomographic data, providing a low-cost algorithm for this task. We compare our formula against other fast transposition techniques, using real and simulated large data sets.

7 October 2010 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
EMEduardo Miqueles
Eduardo Miqueles
APAlvaro R. De Pierro
Alvaro R. De Pierro
We describe a new approach for the inversion of the generalized attenuated radon transform in X-ray fluorescence computed tomography (XFCT). The approach consists of using the radon inverse as an approximation for the actual one, followed by an iterative refinement. Also, we analyze the problem of retrieving the attenuation map directly from the emission data, giving rise to a novel alternating method for the solution. We applied our approach to real and simulated XFCT data and compared its performance to previous inversion algorithms for the problem, showing its main advantages: better images than those obtained by other analytic methods and much faster than iterative methods in the discrete setting.

2 September 2023 in Communications Materials
Verified
Journal Article
Open access
PDF file
RGRadosław Górecki
Radosław Górecki
CPCarla Cristina Polo
Carla Cristina Polo
TKTiago Araujo Kalile
Tiago Araujo Kalile
EMEduardo Miqueles
Eduardo Miqueles
YTYuri R. Tonin
Yuri R. Tonin
SNSuzana Nunes
Suzana Nunes
New visualization methods can be utilized to resolve structures at resolutions that were previously unachievable. 3D images of porous materials with high resolution have been so far obtained using transmission electron tomography or focused ion beam coupled with scanning electron microscopy. For these methods, ultra-vacuum is required, and only a small volume of the sample is visualized. Here, we demonstrate the application of ptychographic X-ray computed tomography for the visualization of soft matter with a resolution of 26 nm over large fields of view. Thanks to the high-penetration depth of the X-ray beam, we visualize the 3D complex porous structure of polyetherimide hollow fibers in a non-destructive manner and obtain quantitative information about pore size distribution and pore network interconnectivity across the whole membrane wall. The non-destructive nature of this method, coupled with its ability to image samples without requiring modification or a high vacuum environment, makes it valuable in the fields of porous- and nano-material sciences enabling imaging under different environmental conditions.

7 April 2017 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
RVR. F. C. Vescovi
R. F. C. Vescovi
MCM. B. Cardoso
M. B. Cardoso
EMEduardo Miqueles
Eduardo Miqueles