The purpose of this study was to ascertain whether a correlation exists between glaucoma-associated alteration of ocular vascular haemodynamics and endothelin-1 (ET-1) levels exist. Eyes of patients with cataract (n = 30) or glaucoma (n = 68) were examined with optical coherence tomography (OCT) and OCT-angiography (OCT-A; AngioVue™-RTVue-XR; Optovue, Fremont, California, USA). The peripapillary and the macular vessel density (VD) values were measured. Inferior and superior retinal nerve fibre layer (RNFL) thickness loss was used for further OCT staging. Aqueous humour of the examined eye and plasma were sampled during cataract or glaucoma surgery and analysed by means of ELISA to determine their ET-1 level. Glaucoma eyes are characterised by reductions in RNFL thickness and VD that correlate significantly with the OCT GSS score. Peripheral and ocular ET-1 level were significantly elevated in patients with glaucoma and correlate positively with the OCT-GSS score of the entire study population. Peripapillary and macula VD of glaucoma patients correlates negatively with plasma ET-1 levels. Multivariable analysis showed a subordinate role of intraocular pressure predictive factor for impaired retinal blood flow compared with plasma ET-1 level in glaucoma. Peripheral ET-1 level serves as risk factor for detection of ocular blood flow changes in the optic nerve head region of glaucomatous eyes.
Being the primary site of degeneration, the optic nerve has always been the focus of structural glaucoma assessment. The technical advancements, mainly of optical coherence tomography (OCT), now allow for a very precise quantification of the optic nerve head and peripapillary retina morphology. By far the most commonly used structural optic nerve parameter is the thickness of the parapapillary retinal nerve fiber, which has great clinical utility but also suffers from significant limitations, mainly in advanced glaucoma. Emerging novel imaging technologies, such as OCT angiography, polarization-sensitive or visible-light OCT and adaptive optics, offer new biomarkers that have the potential to significantly improve structural glaucoma diagnostics. Another great potential lies in the processing of the data already available. Artificial intelligence does not only help increase the reliability of current biomarkers but can also integrate data from various imaging modalities and other clinical measures to increase diagnostic accuracy. And it can, in a more efficient way, draw information from available datasets, such as an OCT scan, compared to the current concept of biomarkers, which only use a fraction of the whole dataset.
18 May 2018 in International Journal of Ophthalmology
AIM: To evaluate whether optical coherence tomography angiography (OCTA) can detect altered vessel density (VD) at the optic nerve head (ONH) in glaucoma patients. Special attention is paid to the accuracy of the OCTA technique for distinguishing healthy from glaucomatous eyes. METHODS: A total of 171 eyes were examined by the OCTA system AngioVue T (Optovue): 97 eyes diagnosed with glaucoma and 74 healthy control eyes. The papillary and peripapillary VD was measured. Furthermore, the VD was correlated with different structural and functional measurements. In order to test the accuracy of differentiation between eyes with and without glaucoma, we calculated the receiver operating characteristic curve (ROC) and the area under the curve (AUC). RESULTS: The papillary and peripapillary VD in glaucomatous eyes was significantly lower than in healthy eyes (P< 0.05). The VD of the nasal peripapillary sector was significantly lower than in the other sectors. The further the disease had progressed [measured by determining the thickness of the ganglion cell complex (GCC) and the retinal nerve fiber layer (RNFL)] the greater the VD reduction. The AUC discriminated well between glaucomatous and normal eyes (consensus classifier 94.2%). CONCLUSION: OCTA allows non-invasive quantification of the peripapillary and papillary VD, which is significantly reduced in glaucomatous eyes and accurately distinguishes between healthy and diseased eyes. OCTA expands the spectrum of procedures for detecting and monitoring glaucoma.
Purpose: To compare papillary and macular vessel density (VD), as measured by optical coherence tomography angiography (OCTA), in eyes with primary open-angle glaucoma (POAG), normal-tension glaucoma (NTG) and exfoliation glaucoma (XFG). Methods: The papillary and macular VD of 40 eyes with POAG, 19 with NTG and 21 with XFG were examined using OCTA (AngioVue™). The VD was measured at two different layers of segmentation (optic nerve head: radial peripapillary capillary [RPC] and nerve head [NH]; macula: superficial [SL] and deep [DL] retinal vascular plexus) with a 4.5×4.5mm papillary and 6×6-mm macular scan. VD was calculated by an automated density measuring tool in the AngioVue™ software. Results: There were no significant differences in the total value of the papillary, peripapillary and macular VD. A significantly higher VD could be measured for NTG compared to POAG, as well as for XFG in the inferior nasal peripapillary sector at RPC-segmentation and at the NH-level between NDG and XFG. Conclusion: OCTA can detect a difference in VD in the nasal inferior peripapillary sector in NTG compared with POAG and XFG. These findings may help to improve the understanding of further pathophysiological mechanisms.