Light reflectance value (LRV) of indoor surfaces impacts on electricity consumption for lighting. For this reason, inner surface reflectance is one of the parameters required by building energy efficiency codes and standards. In countries with advanced building energy certification processes, the LRV of coatings and paints is given by manufacturers. However, at regional and local level, these data are generally not available. In this context, the following problem arises: regional standards demand certifiers to determine the LRV of interior surfaces for the calculation of electric energy consumption by artificial lighting without proposing any tool or methodology for its calculation. Against this background, the main objective of the present work is to develop a simplified and low cost tool for the determination of LRV of inner surfaces materials. The methodology used is divided into three stages: (i) data (LRV, colour, type of material) collection, systematization and classification of materials; (ii) statistical analysis; (iii) development of the surface material card. Results show that a sample of the same material and colour may show variations in its LRV of up to 86%. This highlights the importance of the development of methods and tools, according to socio-technological contexts, for the determination of the LRV.
15 December 2015 in Lighting Research & Technology
While the use of satellite weather files is a possibility in regions without terrestrial stations, it is necessary to consider their impact on daylight simulations. This paper aims to verify the variability of dynamic daylight simulation results according to the weather file used. This study compares the results of daylight simulations in learning spaces using different weather files (land-based station data and satellite data). This work is divided into three main stages: comparative analysis of climatic databases; comparative analysis of annual outside horizontal illuminance; analysis of dynamic daylight performance metrics. Annual calculated dynamic daylight metric indicates variations of up to 13% under the different weather files analysed. This is a relevant topic since the accurate prediction of daylight levels for indoor environments guides daylighting design.
When solar radiation passes through a window, its spectral composition changes due to the presence of shades and glazing. While many studies have analysed the impact of different types of glass on correlated colour temperature (CCT), there are only a few cases in which the effect of shading and daylighting systems on this parameter was tested. This work analyses the impact of woven shade fabrics on the spectrum and intensity of daylight conditions in indoor spaces. A combined analysis of horizontal illuminance ( Eh) and CCT was performed. It focused on the impact that physical properties of woven shade fabrics – colour and openness factor (OF) – had on the CCT and Eh values. In this study, 11 fabrics with different colours (white, grey and black) and varying OF were analysed. For the set of studied woven shade fabrics, it was found that fabric OF and colour had a significant effect on CCT and Eh. Results show that white and grey fabrics provided spaces with lower values of CCT than black fabrics. CCT values were compared with those proposed by standard EN 12464-1:2011.
Benefits of urban trees are evident from the energy and environmental perspective, likewise they reduce glare and control light intensity. Given the hypothesis that trees reduce visible radiation significantly reaching lower level façades, this study is an approach to the analysis of urban forestation as a solar control element. The methodology employed involves measurement of: illuminance – transmittance variation, permeability variation and luminance contrast, by levels along the vertical development of the tree. Vertical illuminance values that exceed 25,000 lx were detected from 5.5 m onwards and values inferior to 3500 lx under that height. Based on the daily analysis of mulberry trees permeability variation in the visible spectrum, it is noted that incident radiation decreases by 90%, with 15% of variability. Natural light analysis must be differentiated by height since daylight scenarios vary accordingly.