Recording human gestures from a wearable sensor produces valuable information to implement control gestures or in healthcare services. The wearable sensor is required to be small and easily worn. Advances in miniaturized sensor and materials research produces patchable inertial measurement units (IMUs). In this paper, a hand gesture recognition system using a single patchable six-axis IMU attached at the wrist via recurrent neural networks (RNN) is presented. The IMU comprises IC-based electronic components on a stretchable, adhesive substrate with serpentine-structured interconnections. The proposed patchable IMU with soft form-factors can be worn in close contact with the human body, comfortably adapting to skin deformations. Thus, signal distortion (i.e., motion artifacts) produced for vibration during the motion is minimized. Also, our patchable IMU has a wireless communication (i.e., Bluetooth) module to continuously send the sensed signals to any processing device. Our hand gesture recognition system was evaluated, attaching the proposed patchable six-axis IMU on the right wrist of five people to recognize three hand gestures using two models based on recurrent neural nets. The RNN-based models are trained and validated using a public database. The preliminary results show that our proposed patchable IMU have potential to continuously monitor people’s motions in remote settings for applications in mobile health, human–computer interaction, and control gestures recognition.
Silicon nanowires are widely used for sensing applications due to their outstanding mechanical, electrical, and optical properties. However, one of the major challenges involves introducing silicon-nanowire arrays to a specific layout location with reproducible and controllable dimensions. Indeed, for integration with microscale structures and circuits, a monolithic wafer-level process based on a top-down silicon-nanowire array fabrication method is essential. For sensors in various electromechanical and photoelectric applications, the need for silicon nanowires (as a functional building block) is increasing, and thus monolithic integration is highly required. In this paper, a novel top-down method for fabricating vertically-stacked silicon-nanowire arrays is presented. This method enables the fabrication of lateral silicon-nanowire arrays in a vertical direction, as well as the fabrication of an increased number of silicon nanowires on a finite dimension. The proposed fabrication method uses a number of processes: photolithography, deep reactive-ion etching, and wet oxidation. In applying the proposed method, a vertically-aligned silicon-nanowire array, in which a single layer consists of three vertical layers with 20 silicon nanowires, is fabricated and analyzed. The diamond-shaped cross-sectional dimension of a single silicon nanowire is approximately 300 nm in width and 20 μm in length. The developed method is expected to result in highly-sensitive, reproducible, and low-cost silicon-nanowire sensors for various biomedical applications.
Technological advances in wireless communications, miniaturized sensors, and low-power electronics have made it possible to implement integrated wireless body area networks (WBANs). These developments enable the applications of wireless wearable systems for diagnosis, health monitoring, rehabilitation, and dependency care. Across the current range of commercial wearable devices, the products are not firmly fixed to the human body. To minimize data error caused by movement of the human body and to achieve accurate measurements, it is essential to bring the wearable device close to the skin. This paper presents the implementation of a patch-type, six-axis inertial measurement unit (IMU) with wireless communication technology. The device comprises hard-electronic components on a stretchable elastic substrate for application in epidermal electronics, to collect precise data from the human body. Instead of the commonly used cleanroom processes of implementing devices on a stretchable substrate, a simple and inexpensive “cut-solder-paste” method is adopted to fabricate complex, convoluted interconnections. Thus, the signal distortions in the proposed device can be minimized during various physical activities and skin deformations when used in gait analysis. The inertial sensor data measured from the motion of the body can be sent in real-time via Bluetooth to any processing unit enabled with such a widespread standard wireless interface. For performance evaluation, the implemented device is mounted on a rotation plate in order to compare performance with the conventional product. In addition, an experiment on joint angle estimation is performed by attaching the device to an actual human body. The preliminary results of the device indicate the potential to monitor people in remote settings for applications in mobile health, human-computer interfaces (HCIs), and wearable robots.
Silicon nanowires (SiNWs) are emerging as versatile components in the fabrication of sensors for implantable medical devices because of their exceptional electrical, optical, and mechanical properties. This paper presents a novel top-down fabrication method for vertically stacked SiNWs, eliminating the need for wet oxidation, wet etching, and nanolithography. The integration of these SiNWs into body channel communication (BCC) circuits was also explored. The fabricated SiNWs were confirmed to be capable of forming arrays with multiple layers and rows. The SiNW-based pH sensors demonstrated a robust response to pH changes, and when tested with BCC circuits, they showed that it was possible to quantize based on pH when transmitting data through the human body. This study successfully developed a novel method for SiNW fabrication and integration into BCC circuits, which could lead to improvements in the reliability and efficiency of implantable medical sensors. The findings demonstrate significant potential for bioelectronic applications and real-time biochemical monitoring.
BACKGROUND: In retinal prosthetic systems on multi-channel microelectrodes to effectively stimulate retinal neurons, the electrode-electrolyte interface impedance of a microelectrode should be minimized to drive sufficiently large current at a given supply voltage. OBJECTIVE: This paper presents the fabrication of the nanostructured microelectrode array with simplified fabrication and its characteristic evaluation using biphasic current stimulator. METHODS: The nanostructured microelectrodes with the base diameter of 25 μm, 50 μm, 75 μm are fabricated, and the maximum allowable current injection limits are measured to verify the estimated injection limit. Also, a biphasic stimulator has been fabricated using the 2-stage amplifier and 4 switches based on a stimulator cell. The adjustable load resistance is adopted to control between 5 kΩ to 20 kΩ, and the biphasic stimulator can drive the stimulation current between 50 uA and 200 uA. RESULTS: The proposed electrode-electrolyte interface impedance of the fabricated nanostructured microelectrode is 3178 Ω, 1218 Ω and 798.8 Ω for electrodes with diameter of 25 μm, 50 μm, 75 μm, respectively. CONCLUSION: This paper shows the advantages of the nanostructured microelectrode arrays for high resolution retinal prostheses, which could be a basic experiment for artificial retina research.
This paper presents an integrated approach for a retinal prosthesis that overcomes the scalability challenges and limitations of conventional systems that use external cameras. Silicon nanowires (SiNWs) are utilized as photonic sensors due to their nanoscale dimensions and high surface-to-volume ratio. To enhance these properties and achieve high photoresponsivity, our research team developed a vertically stacked SiNW structure using a fabrication method entirely based on dry etching. The fabricated SiNW photodetector demonstrated excellent electrical and optical characteristics, including linear I–V characteristics that confirmed ohmic contact formation and high photoresponsivity exceeding 105 A/W across the 400–800 nm wavelength range. The SiNW photodetector, following its integration with a switched capacitor stimulator circuit, exhibited a proportional increase in stimulation current in response to higher light intensity and increased SiNW density. In vitro experiments confirmed the efficacy of the integrated system in inducing neural responses from retinal cells, as indicated by an increased number of neural spikes observed at higher light intensities and SiNW densities. This study contributes to sensor technology by demonstrating an approach to integrating nanostructures and electronic components, which enhances control and functionality.