Fault detection is very important to improve the reliability of power conversion devices. Faults of power semiconductors can be broadly divided into shorts and opens and are further classified into two types depending on whether there is an internal problem with the switch or anti-parallel diode. In this paper, fault-diagnosis methods for short-circuit and open-circuit states are proposed, respectively. A method of classifying and diagnosing faults by applying a gate signal to each switch is proposed to diagnose short-circuit conditions. This method uses only current magnitude information, which reduces the amount of required information and reduces diagnostic failures due to angle errors and current noise. A method is proposed to detect a faulty switch by applying a voltage vector and comparing the current angle with a lookup table to diagnose an open state. An iterative diagnostic algorithm is proposed to prevent diagnostic failure due to angle error and current noise. The effectiveness of the proposed diagnosis method is verified through experiments and simulations.
In this study, wafer cleaning equipment was designed and fabricated using the induction heating (IH) method and a short-time superheated steam (SHS) generation process. To prevent problems arising from the presence of particulate matter in the fluid flow region, pure grade 2 titanium (Ti) R50400 was used in the wafer cleaning equipment for heating objects via induction. The Ti load was designed and manufactured with a specific shape, along with the resonant network, to efficiently generate high-temperature steam by increasing the residence time of the fluid in the heating object. The IH performance of various shapes of heating objects made of Ti was analyzed and the results were compared. In addition, the heat capacity required to generate SHS was mathematically calculated and analyzed. The SHS heating performance was verified by conducting experiments using the designed 2.2 kW wafer cleaning equipment. The performance of the proposed pure Ti-based SHS generation system was found to be satisfactory, and SHS with a temperature higher than 200 °C was generated within 10 s using this system.
1 March 2017 in Journal of Electrical Engineering & Technology
Turn-on Loss Reduction for High Voltage Power Stack Using Active Gate Driving Method Active gate drive;Insulated Gate Bipolar Transistor (IGBT) gate driver;IGBT;Medium-voltage drive; This paper presents an improved approach towards reducing the switching loss of insulated gate bipolar transistors (IGBTs) for a medium-capacity-class power conditioning system (PCS). In order to improve the switching performance, the switching operation is analyzed, and based on this analysis, an improved switching method that reduces the switching time and switching loss is proposed. Compared to a conventional gate drive scheme, the switching loss, switching time, and delay are improved in the proposed gate driving method. The performance of the proposed gate driving method is verified through several experiments.
This paper proposes an energy-efficient current control strategy for drive modules of permanent magnetic actuators (PMAs) to reduce the cost and volume of DC-link capacitors. The drive module of the PMA does not receive the input power from an external power source during operation. Instead, the externally charged DC-link capacitors are used as internal backup power sources to guarantee the reliable operation even in the case of an emergency. Therefore, it is important to use the charged energy efficiently within the limited DC-link capacitors. However, conventional control strategies using a voltage open loop have trouble reducing the energy waste. This is because the drive module with the voltage open loop uses unnecessary energy even after the PMA mover has finished its movement. To figure it out, the proposed control strategy adopts a current control loop to save energy even if the displacement of the PMA mover is unknown. In addition, the proposed strategy can ensure the successful operation of the PMA by using the driving force analysis. The efficacy of the proposed strategy is verified through the experimental test. It would be expected that the proposed strategy can reduce the cost and volume of the PMA drive system.
27 June 2026 in Journal of Electrical Engineering & Technology