Three-dimensional kinematic analysis equipment is a valuable instrument for studying the execution of movement during functional activities of the upper limbs. The aim of this study was to analyze the kinematic differences in the execution of a daily activity such as drinking from a glass between two groups of patients with tetraplegia and a control group.
2 February 2011 in Journal of NeuroEngineering and Rehabilitation
Central cord syndrome (CCS) is considered the most common incomplete spinal cord injury (SCI). Independent ambulation was achieved in 87-97% in young patients with CCS but no gait analysis studies have been reported before in such pathology. The aim of this study was to analyze the gait characteristics of subjects with CCS and to compare the findings with a healthy age, sex and anthropomorphically matched control group (CG), walking both at a self-selected speed and at the same speed. Twelve CCS patients and a CG of twenty subjects were analyzed. Kinematic data were obtained using a three-dimensional motion analysis system with two scanner units. The CG were asked to walk at two different speeds, at a self-selected speed and at a slower one, similar to the mean gait speed previously registered in the CCS patient group. Temporal, spatial variables and kinematic variables (maximum and minimum lower limb joint angles throughout the gait cycle in each plane, along with the gait cycle instants of occurrence and the joint range of motion - ROM) were compared between the two groups walking at similar speeds. The kinematic parameters were compared when both groups walked at a similar speed, given that there was a significant difference in the self-selected speeds (p < 0.05). Hip abduction and knee flexion at initial contact, as well as minimal knee flexion at stance, were larger in the CCS group (p < 0.05). However, the range of knee and ankle motion in the sagittal plane was greater in the CG group (p < 0.05). The maximal ankle plantar-flexion values in stance phase and at toe off were larger in the CG (p < 0.05). The gait pattern of CCS patients showed a decrease of knee and ankle sagittal ROM during level walking and an increase in hip abduction to increase base of support. The findings of this study help to improve the understanding how CCS affects gait changes in the lower limbs.
16 October 2024 in IEEE Transactions on Instrumentation and Measurement
3D force plates are used to measure the ground reaction forces/moments and the center of pressure (COP) during the stance phase of walking. Force plates consist of three essential components, i.e., lower platform, upper platform (typically with square or rectangular shape) and some load cells between both platforms. The design of the load cells, their location in the force plate and the type of sensors used in the load cells determine the main differences. Two types of sensors are usually used in load cells: resistive strain gauges and piezoelectric crystals. Commercial force plates usually have four 3D load cells located at the corners of the plate. The number of resistive strain gauges used commonly in each load cell of force plates based on resistive strain gauges is twenty-four, whereas piezoelectric force plates have three orthogonal piezoelectric sensors packaged in each load cell. Although the operational performance of commercial force plates is very good, they are very expensive, and many research groups cannot afford to buy them. A novel 3D force plate for gait analysis is proposed in this study with a simple design that is easy and economical compared to commercial force plates (approximately one-tenth of the cost of commercial force plates). The foot-ground reaction forces/moments and the COP are estimated from only eight force sensors strategically distributed on the force plate. Each force sensor consists of a uniaxial cantilever beam and a strain sensor attached at its fixed end. The design and manufacture of cantilever beam force sensors are simpler and more economical than 3D load cells used in commercial force plates. The cantilever beam force sensors are designed to maximize the signal-force relation and minimize vibration modes. The performance of the proposed force plate (linearity, ±1.6%FSO–Full Scale Output–, hysteresis ±0.5%FSO, accuracy error ±2%AL–Applied Load–, cross-talk ±5%AL, and COP accuracy error, 14.5 mm) has been compared with the performance of other commercial force plates. In general, the deviation of the specifications in our system is slightly greater than in commercial force plates. These deviations might be acceptable if we consider that we used manufacturing methods and machines which are not as precise as those used by companies that manufacture this type of force plate. In addition, two types of strain sensors, resistive strain gauges and piezoelectric paint sensors were compared in this study. Experimental tests showed similar results with both strain sensors. The relative mean difference in the estimation of the forces/moments with both strain sensors was lower than 5% in all cases except the vertical component of the force, Fy, which was about 9%, and the mean difference in the estimation of the COP with both sensors was 11 mm. Therefore, they might be used to design this type of force plate.
The treatment of spinal cord injury (SCI) with uncultivated human bone marrow-derived stromal cells (bmSCs) prepared by negative selection has been proposed to be therapeutically superior to treatment with stem cells that were expanded in vitro. To explore their use in clinical trials, we studied the functional effects of delayed application at 7 days after SCI by testing different doses of bmSCs. Spinal cord contusion injury was induced in adult male Wistar rats at the thoracic level T9. Human bmSCs were prepared by negative selection without expansion in vitro (NeuroCellsTM). Treatment consisted of one 150 µL injection into the cisterna magna containing 0.5 or 2.5 million fresh bmSCs or 2.5 million bmSCs. The recovery of motor functions was evaluated during a surveillance period of six weeks (6 W), during which spinal cords were assessed histologically. Treatment resulted in a significant, dose-dependent therapeutic effect on the recovery of motor performance. The histological analysis revealed a lower degree of axonal degeneration and better survival of neurons and oligodendrocytes in bmSCs treated rats. Our results support delayed intrathecal application of bmSCs prepared by negative selection without expansion in vitro as a treatment of SCI.
Following spinal cord injury (SCI), the regenerative capacity of the central nervous system (CNS) is severely limited by the failure of axonal regeneration. The regeneration of CNS axons has been shown to occur by grafting predegenerated peripheral nerves (PPNs) and to be promoted by the transplantation of neural precursor cells (NPCs). The introduction of a combinatorial treatment of PPNs and NPCs after SCI has to address the additional problem of glial scar formation, which prevents regenerating axons from leaving the implant and making functional connections. Previously, we discovered that the synthetic sulfoglycolipid Tol-51 inhibits astrogliosis. The objective was to evaluate axonal regeneration and locomotor function improvement after SCI in rats treated with a combination of PPN, NPC, and Tol-51. One month after SCI, the scar tissue was removed and replaced with segments of PPN or PPN+Tol-51; PPN+NPC+Tol-51. The transplantation of a PPN segment favors regenerative axonal growth; in combination with Tol-51 and NPC, 30% of the labeled descending corticospinal axons were able to grow through the PPN and penetrate the caudal spinal cord. The animals treated with PPN showed significantly better motor function. Our data demonstrate that PPN implants plus NPC and Tol-51 allow successful axonal regeneration in the CNS.