Federico Ravotti

Dr. Federico Ravotti

EP department, CERN, Geneva, Genève, Switzerland
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2018 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
Federico RavottiFederico Ravotti
Federico Ravotti
This paper will address dosimetry and monitoring techniques for Total Ionizing Dose (TID) testing of electronics devices. We will first discuss the basic principles of dosimetry, as well as the most common dosimetric quantities and units, used for the determination of the energy deposited in a given medium by ionizing radiation. In Section III, we will give an overview of the available dosimetry techniques for ionizing radiation, along with the basic mechanisms exploited for their operation. In Section IV, we will address issues and factors affecting the dosimetry measurements, as well as we will give some practical ‘hints’ about the selection and use of the presented techniques. Finally, a synthesis of the existing radiation test facilities, focusing on the one for TID testing, will be given in Section V. Their interest, limitations and some practical aspects involving the organization of radiation test campaigns will be also discussed in this paper.

1 July 2007
Verified
Conference Paper
Closed access
AHAndrew Holmes-Siedle
Andrew Holmes-Siedle
Federico RavottiFederico Ravotti
Federico Ravotti
MGMaurice Glaser
Maurice Glaser
The radiation-sensitive field-effect transistor (RADFET) is a specialized design of metal-oxide-semiconductor field-effect transistor (MOSFET). This paper gives selected data on the response of REM RADFETs to ionizing radiation. The period extends from 1975 to the present. A wide variety of test beams was used. It includes gamma-ray sources, X-ray sources, medical LINACs, reactors and high-energy charged-particle accelerators. The responses and their measurement are mainly due to the growth of trapped oxide charge, represented by shift in the threshold voltage (V T ). The dependence of charge growth with exposure bias and oxide thickness is described. Also described are instabilities such as room-temperature and isochronal annealing (known as "fade"), drift due to border states and the effect of radiation on the temperature coefficient of threshold voltage.

4 May 2024 in Polymers
Verified
Journal Article
Open access
PDF file
AGAnders Gaarud
Anders Gaarud
CSChristian Scheuerlein
Christian Scheuerlein
DPDavid Mate Parragh
David Mate Parragh
SCSébastien Clement
Sébastien Clement
JBJacob Bertsch
Jacob Bertsch
RLRalf Lach
Ralf Lach
High fracture toughness at cryogenic temperature and radiation hardness can be conflicting requirements for the resins for the impregnation of superconducting magnet coils. The fracture toughness of different epoxy-resin systems at room temperature (RT) and at 77 K was measured, and their toughness was compared with that determined for a polyurethane, polycarbonate (PC) and poly(methyl methacrylate) (PMMA). Among the epoxy resins tested in this study, the MY750 system has the highest 77 K fracture toughness of KIC = 4.6 MPa√m, which is comparable to the KIC of PMMA, which also exhibits linear elastic behaviour and unstable crack propagation. The polyurethane system tested has a much higher 77 K toughness than the epoxy resins, approaching the toughness of PC, which is known as one of the toughest polymer materials. CTD101K is the least performing in terms of fracture toughness. Despite this, it is used for the impregnation of large Nb3Sn coils for its good processing capabilities and relatively high radiation resistance. In this study, the fracture toughness of CTD101K was improved by adding the polyglycol flexibiliser Araldite DY040 as a fourth component. The different epoxy-resin systems were exposed to proton and gamma doses up to 38 MGy, and it was found that adding the DY040 flexibiliser to the CTD101K system did not significantly change the irradiation-induced ageing behaviour. The viscosity evolution of the uncured resin mix is not significantly changed when adding the DY040 flexibiliser, and at the processing temperature of 60 °C, the viscosity remains below 200 cP for more than 24 h. Therefore, the new resin referred to as POLAB Mix is now used for the impregnation of superconducting magnet coils.


1 September 2023 in Journal of Instrumentation
Verified
Journal Article
Open access
ATA. Tumasyan
A. Tumasyan
WAW. Adam
W. Adam
JAJ.W. Andrejkovic
J.W. Andrejkovic
TBThomas Bergauer
Thomas Bergauer
SCS. Chatterjee
S. Chatterjee
JZJ. Zich
J. Zich
The Precision Proton Spectrometer (PPS) of the CMS and TOTEM experiments collected 107.7 fb-1 in proton-proton (pp) collisions at the LHC at 13 TeV (Run 2). This paper describes the key features of the PPS alignment and optics calibrations, the proton reconstruction procedure, as well as the detector efficiency and the performance of the PPS simulation. The reconstruction and simulation are validated using a sample of (semi)exclusive dilepton events. The performance of PPS has proven the feasibility of continuously operating a near-beam proton spectrometer at a high luminosity hadron collider.

25 March 2019 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
PMPablo Fernández Martínez
Pablo Fernández Martínez
RARuben Garcia Alia
Ruben Garcia Alia
MCMatteo Cecchetto
Matteo Cecchetto
MKMaria Kastriotou
Maria Kastriotou
NKNourdine Kerboub
Nourdine Kerboub
RGRemi Gaillard
Remi Gaillard
Taking advantage of the heavy ion acceleration program, tests on radiation effects with Ultra High Energy (UHE) xenon ion beams (with Energy >5 GeV/nucleon) have been performed in several experimental areas of the CERN accelerator complex. Specifically, the outcomes of the first UHE heavy ion test campaign carried out at the CHARM facility are presented and discussed in this contribution. UHE ion beams have the advantage of not requiring a previous modification of the samples or testing in vacuum, owing to their large penetration range. The unic nature of the UHE ions motivated the study of their interaction with matter, with regard to the induction of SEE. To that end, great effort was paid on the calibration of the beam-line instrumentation, typically prepared for the traditional proton runs. Electronic components sensitive to Single Event Upset (SEU) and Single Event Latchup (SEL) were irradiated by an UHE xenon beam, with a particular interest in studying the sub-LET cross section region and benchmarking against the standard heavy ion test beams. Finally, the suitability of UHE ion testing for Radiation Hardness Assurance is also discussed in the contribution.