Fangmeng Liu

Prof. Dr. Fangmeng Liu


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2019 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
LZLianjing Zhao
Lianjing Zhao
ZWZepei Wu
Zepei Wu
GLGuannan Liu
Guannan Liu
HLHuiying Lu
Huiying Lu
YGYuan Gao
Yuan Gao
GLGeyu Lu
Geyu Lu
Nanozymes have drawn considerable attention because of their lower cost, higher stability and convenient preparation compared to protein enzymes. In the present work, Mo, S co-doped carbon quantum dots (Mo-CQDs) as a peroxidase mimic were used to fabricate a cascade colorimetric biosensor to detect cholesterol. The Mo-CQDs possess a robust peroxidase-like activity, and they can easily catalyze 3,3,5,5-tetramethylbenzidine (TMB) to produce an oxidized TMB in the presence of H2O2. The Mo, S doping in the carbon quantum dots (CQDs) notably boosts the yield of CQDs and may facilitate the electron transfer between TMB and H2O2, which further enhances the catalytic activity of CQDs. The colorimetric biosensor based on Mo-CQDs and cholesterol oxidase exhibited excellent selectivity and high sensitivity for cholesterol in the range of 0.01–1.0 mM along with a detection limit as low as 7 μM. The total cholesterol concentration in the serum sample was measured with satisfactory results and read out by the naked eye, indicating the potential application in clinical diagnosis and portable test kits.

10 April 2024 in InfoMat
Verified
Journal Article
Open access
YLYiwen Li
Yiwen Li
SGShuai Guo
Shuai Guo
BWBoyi Wang
Boyi Wang
JSJianguo Sun
Jianguo Sun
LZLiupeng Zhao
Liupeng Zhao
GLGeyu Lu
Geyu Lu
The fast booming of wearable electronics provides great opportunities for intelligent gas detection with improved healthcare of mining workers, and a variety of gas sensors have been simultaneously developed. However, these sensing systems are always limited to single gas detection and are highly susceptible to the inference of ubiquitous moisture, resulting in less accuracy in the analysis of gas compositions in real mining conditions. To address these challenges, we propose a synergistic strategy based on sensor integration and machine learning algorithms to realize precise NH3 and NO2 gas detections under real mining conditions. A wearable sensing array based on the graphene and polyaniline composite is developed to largely enhance the sensitivity and selectivity under mixed gas conditions. Further introduction of backpropagation neural network (BP‐NN) and partial least squares (PLS) algorithms could improve the accuracy of gas identification and concentration prediction and settle the inference of moisture, realizing over 99% theoretical prediction level on NH3 and NO2 concentrations within a wide relative humidity range, showing great promise in real mining detection. As proof of concept, a wireless wearable bracelet, integrated with sensing arrays and machine‐learning algorithms, is developed for wireless real‐time warning of hazardous gases in mines under different humidity conditions. image

5 February 2022 in Nano-Micro Letters
Verified
Journal Article
Open access
PDF file
ZYZijie Yang
Zijie Yang
SLSiyuan Lv
Siyuan Lv
YZYueying Zhang
Yueying Zhang
JWJing Wang
Jing Wang
LJLi Jiang
Li Jiang
GLGeyu Lu
Geyu Lu
Environmentally friendly degradable sensors with both hazardous gases and pressure efficient sensing capabilities are highly desired for various promising applications, including environmental pollution monitoring/prevention, wisdom medical, wearable smart devices, and artificial intelligence. However, the transient gas and pressure sensors based on only identical sensing material that concurrently meets the above detection needs have not been reported. Here, we present transient all-MXene NO2 and pressure sensors employing three-dimensional porous crumpled MXene spheres prepared by ultrasonic spray pyrolysis technology as the sensing layer, accompanied with water-soluble polyvinyl alcohol substrates embedded with patterned MXene electrodes. The gas sensor achieves a ppb-level of highly selective NO2 sensing, with a response of up to 12.11% at 5 ppm NO2 and a detection range of 50 ppb–5 ppm, while the pressure sensor has an extremely wide linear pressure detection range of 0.14–22.22 kPa and fast response time of 34 ms. In parallel, all-MXene NO2 and pressure sensors can be rapidly degraded in medical H2O2 within 6 h. This work provides a new avenue toward environmental monitoring, human physiological signal monitoring, and recyclable transient electronics.

25 August 2022 in Analytical Chemistry
Verified
Journal Article
Closed access
GPGuishan Peng
Guishan Peng
JDJianan Dai
Jianan Dai
RZRi Zhou
Ri Zhou
GLGuannan Liu
Guannan Liu
XLXiaomin Liu
Xiaomin Liu
GLGeyu Lu
Geyu Lu

21 April 2022 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
YZYue Zhou
Yue Zhou
LZLiupeng Zhao
Liupeng Zhao
WTWei Tao
Wei Tao
TWTianshuang Wang
Tianshuang Wang
PSPeng Sun
Peng Sun
GLGeyu Lu
Geyu Lu

8 November 2023 in ACS Sensors
Verified
Journal Article
Closed access
YLYiwen Li
Yiwen Li
YZYibo Zhang
Yibo Zhang
YZYun Zhou
Yun Zhou
LZLiupeng Zhao
Liupeng Zhao
Xu YanXu Yan
Xu Yan
PSPeng Sun
Peng Sun