Zhu Qing

Zhu Qing

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
ZQZhu Qing
Zhu Qing
YSYu Su
Yu Su
Currently, cutting-edge, high-frequency current sources are limited by switching devices and wire materials, and the output current cannot take into account the demands of a high peak and low rise time at the same time. Based on the output demand of a current source, a non-inductive coil for providing high-frequency, high current sources with low rise times is designed. The coil is appropriately designed according to the principle of the ampere-turn method, where several turns of wire are utilized to linearly synthesize the current to obtain high-frequency currents with amplitudes up to 30 kA. However, the inductance formed after winding the coil could possess a hindering effect on the high-frequency current. In the present investigation, based on the law of energy conservation and utilizing the principle of transformer coupling, the inductor’s hindering effect on high-frequency currents is appropriately eliminated by consuming the stored energy of the inductor innovatively. Theoretical calculations and practical tests show that the inductance of a two-layer 28-turn coil is 42 times smaller than that of a two-layer, 28-turn perfect circular spiral PCB coil. The measured inductance is only 6.69 μH, the output current amplitude is calculated to be up to 33 kA with a rise time of 20 ns, and the output waveform corresponding to a 1 MHz square wave is not remarkably distorted. This effective design idea could be very helpful in solving the problem of high peak values and low rise times in high-frequency, high-current source output design.

1 March 2024 in AIP Advances
Verified
Journal Article
Open access
PDF file
ZQZhu Qing
Zhu Qing
YSYu Su
Yu Su
ZZZhen Zhang
Zhen Zhang
FLFei Liu
Fei Liu
QLQing Liu
Qing Liu
The accurate large-scale positioning system is a novel full-space laser positioning system that has the advantages of automatic and multi-node parallel measurement and sub-millimeter positioning accuracy, and it has become an important component in the digital manufacturing of large equipment. Goniometric accuracy is particularly important for the evaluation of system function and accuracy improvement. An improved goniometric accuracy calibration method is proposed to assess the goniometric accuracy by using multiple measurement points to fit the mapping relationship between the goniometric measurement of the system and the goniometric measurement of the multi-tooth indexing table. The feasibility of the accuracy assessment method is verified by establishing a geometric model and performing modeling and simulation analysis. The method is verified using an all-space laser positioning system, and the dynamic performance of the base station is optimized to improve the overall goniometric accuracy. The maximum value of the goniometric error is 0.008″ and the goniometric accuracy is 0.026″ after fitting the curve by the mapping relation, demonstrating high stability, and the fluctuation of the goniometric error after optimization is improved from the original ±15″ to ±7.5″, verifying the effectiveness of the goniometric compensation method. This method solves the problem of coaxiality calibration in goniometric evaluation and provides the basis for the traceability of the goniometric accuracy.