Monika Komar

Dr. Monika Komar


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2014 in Cardiovascular Ultrasound
Verified
Journal Article
Open access
PDF file
MKMonika Komar
Monika Komar
MOMaria Olszowska
Maria Olszowska
TPTadeusz Przewłocki
Tadeusz Przewłocki
JPJakub Podolec
Jakub Podolec
JSJakub Stępniewski
Jakub Stępniewski
PPPiotr Podolec
Piotr Podolec
Persistent foramen ovale (PFO) is considered a cause of cryptogenic stroke and a risk factor for neurological events in young patients. The reference standard for identifying a PFO is contrast-enhanced transesophageal echocardiography (TEE).

1 July 2014 in Clinical Interventions in Aging
Verified
Journal Article
Open access
MKMonika Komar
Monika Komar
TPTadeusz Przewlocki
Tadeusz Przewlocki
MOMaria Olszowska
Maria Olszowska
BSBartosz Sobien
Bartosz Sobien
PPPiotr Podolec
Piotr Podolec
Objective: Closure of an atrial septal defect in elderly patients is controversial. The aim of the study was to evaluate the outcomes of transcatheter closure of secundum atrial septal defects (ASDs) in elderly patients. Patients and methods: From a total of 488 patients with ASDs who underwent transcatheter closure, 75 patients aged over 60 years (45 female, 30 male) with a mean age of 65.3±15.7 (60–75) years were analyzed. All patients had an isolated secundum ASD with a mean pulmonary blood flow:systemic blood flow of 2.84±1.9 (1.5–3.9). Symptom-limited treadmill exercise tests with respiratory gas-exchange analysis and transthoracic color Doppler echocardiographic study, as well as quality of life measured using the Short Form (36) Health Survey (SF-36) were repeated in all patients before the procedure and after 12 months of follow-up. Results: The atrial septal device was successfully implanted in all patients (procedure time 37.7±4.5 [13–59] minutes, fluoroscopy time 11.2±9.9 [6–40] minutes). There were no major complications. The defect echo diameter was 17.7±15.8 (12–30) mm. The mean balloon-stretched diameter of ASDs was 22.4±7.9 (14–34) mm. The diameter of the implanted devices ranged from 16 to 34 mm. Significant improvement of exercise capacity was noted at 6 and 12 months after the procedure. Exercise time within 6 months of ASD closure was longer (P<0.001) compared to baseline values, and also oxygen consumption increased (P<0.001). Seven quality-of-life parameters (except mental health) improved at 12-month follow-up compared to baseline data. The mean SF-36 scale increased significantly in 66 (88%) patients, with a mean of 46.2±19.1 (5–69). As early as 1 month after the procedure, a significant decrease of the right ventricular dimension and the right atrium dimension was observed (P<0.001). The right ventricular dimension decreased in 67 patients (89.3%). Conclusion: Closure of ASDs in elderly patients caused significant clinical and hemodynamic improvement after percutaneous treatment, which was maintained during long-term follow-up, justifying this procedure in old age.

10 April 2014 in Cardiovascular Ultrasound
Verified
Journal Article
Open access
PDF file
LTLidia Tomkiewicz-Pająk
Lidia Tomkiewicz-Pająk
HDHanna Dziedzic-Oleksy
Hanna Dziedzic-Oleksy
JPJacek Władysław Pająk
Jacek Władysław Pająk
MOMaria Olszowska
Maria Olszowska
JKJacek Kolcz
Jacek Kolcz
PPPiotr Podolec
Piotr Podolec
Increased arterial stiffness is a risk factor of atherosclerosis and cardio-vascular complications. The aim of the study was to determine whether peripheral vascular function might be an early marker of impaired health status in patients with a single ventricle after Fontan procedure. Twenty five consecutive adults (11 women and 14 men) aged 24.7 ± 6.2 years after the Fontan procedure and 25 sex, age and BMI match healthy volunteers underwent physical examination, blood analysis, transthoracic echocardiography and noninvasive assessment of aortic stiffness. Augmented pressure and Augmentation Index (AIx) were both significantly elevated in Fontan when compared to the controls (6,08 ± 0,7 vs. 2,0 ± 3,7; p = 0.002 and 17,01 ± 3,3 vs. 6,05 ± 11; p < 0.001, respectively). There were no differences in pulse wave velocity (PWV), mean blood pressure (BP), brachial pulse pressure (PP), central: systolic BP, diastolic BP and PP. In Fontan group we find negative correlation between PWV and SatO2 (r = -0.68; p = 0.04) and positive correlation with WBC (0.72; p = 0.72; p = 0.013), INR (0.81; p = 0.008), TNFα (r = 0.45; p = 0.04), and postoperative time (r = 0.77; p = 0.02). AIx correlates positively only with age at surgery (r = 0.45; p = 0.04). Bilirubin level correlates positively with brachial PP (r = 0.71; p = 0.02) and central PP (r = 0.68; p = 0.03).The multivariate model showed that SatO2 (β = -0.44, p = 0.04) was the only independent predictor of PWV (R² = 0.32, p = 0.03). Adult Fontan patients have an increased arterial stiffness assessed by a noninvasive technique. Low arterial oxygen saturation postoperative time, age at surgery, white blood cells, TNFα and bilirubin level are associated with arterial stiffening in these patients. The combination of blood parameters of the hepatic function and noninvasive measurements of arterial stiffness could be helpful in comprehensive care of patients with Fontan circulation.

1 January 2014 in Circulation Journal
Verified
Journal Article
Open access
PDF file
MKMonika Komar
Monika Komar
TPTadeusz Przewłocki
Tadeusz Przewłocki
MOMaria Olszowska
Maria Olszowska
BSBartosz Sobień
Bartosz Sobień
JSJakub Stępniewski
Jakub Stępniewski
PPPiotr Podolec
Piotr Podolec
Background:The aim of this study was to prospectively perform ambulatory 24-h ECG monitoring to assess the effects of transcatheter closure of atrial septal defect (ASD).Methods and Results:A total of 235 consecutive subjects (female, n=163; male, n=72; age, 44.6±14.4 years) were enrolled in the study, who were due undergo ASD closure. Holter monitoring was performed before procedure and at 1, 6 and 12 months of follow-up. During the procedure transient supraventricular arrhythmia occurred in 8 patients (3.4%), and bradycardia in 3 (1.3%). In 3 patients (1.3%) an episode of atrial fibrillation occurred in the first hour after the procedure. In 8 patients (3.4%) transient first-degree atrioventricular block was noted. A significant increase in number of supraventricular extrasystoles (SVES)/24 h was noted 1 month after the procedure (P<0.001). On multiple forward stepwise regression analysis, device size and fluoroscopy time had an influence on increase in number of SVES seen 1 month after the procedure (P<0.001).Conclusions:Transcatheter closure of ASD is associated with a transient increase in supraventricular premature beats and a small risk of conduction abnormalities and paroxysmal atrial fibrillation in early follow-up. Transcatheter closure of ASD does not reduce arrhythmia that appears prior to ASD closure. Larger device size and longer procedure time are associated with increased risk of supraventricular arrhythmia on early follow-up. (Circ J 2014; 78: 2415–2421)

1 February 2015 in International Journal of Cardiology
Verified
Journal Article
Closed access
LTLidia Tomkiewicz-Pająk
Lidia Tomkiewicz-Pająk
TWTomasz Wojcik
Tomasz Wojcik
SCStefan Chlopicki
Stefan Chlopicki
MOMaria Olszowska
Maria Olszowska
JPJacek Władysław Pająk
Jacek Władysław Pająk
PPPiotr Podolec
Piotr Podolec

20 April 2018 in Clinical Rheumatology
Verified
Journal Article
Closed access
PDF file
KBKamil Bugała
Kamil Bugała
AMAdam Mazurek
Adam Mazurek
KGKrzysztof Gryga
Krzysztof Gryga
MKMonika Komar
Monika Komar
Grzegorz KopecGrzegorz Kopec
Grzegorz Kopec
WPWojciech Płazak
Wojciech Płazak