Vikas Kumar

Dr. Vikas Kumar

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2025 in AI
Verified
Journal Article
Open access
PDF file
Sasa JenkoSasa Jenko
Sasa Jenko
Elsa PapadopoulouElsa Papadopoulou
Elsa Papadopoulou
VKVikas Kumar
Vikas Kumar
SOSteven S. Overman
Steven S. Overman
KKKatarina Krepelkova
Katarina Krepelkova
Themis ExarchosThemis Exarchos
Themis Exarchos
Background/Objectives: Artificial intelligence (AI) is increasingly integrated into everyday life, including the complex and highly regulated healthcare sector. Given healthcare’s essential role in safeguarding human life and well-being, AI deployment requires careful oversight to ensure safety, effectiveness, and ethical compliance. This paper aims to examine the current regulatory landscapes governing AI in healthcare, particularly in the European Union (EU) and the United States (USA), and to propose practical tools to support the responsible development and implementation of AI systems. Methods: The study reviews key regulatory frameworks, ethical guidelines, and expert recommendations from international bodies, professional associations, and governmental institutions in the EU and USA. Based on this analysis, the paper develops structured questionnaires tailored for AI developers and implementers to help operationalize regulatory and ethical expectations. Results: The proposed questionnaires address critical gaps in existing frameworks by providing actionable, lifecycle-oriented tools that span AI development, deployment, and clinical use. These instruments support compliance and ethical integrity while promoting transparency and accountability. Conclusions: The structured questionnaires can serve as practical tools for health technology assessments, public procurement, accreditation processes, and training initiatives. By aligning AI system design with regulatory and ethical standards, they contribute to building trustworthy, safe, and innovative AI applications in healthcare.

23 February 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
HRHamidreza Rajabzadeh-Oghaz
Hamidreza Rajabzadeh-Oghaz
VKVikas Kumar
Vikas Kumar
DBDavid Berry
David Berry
ASAnshu Singh
Anshu Singh
BSBradley S. Schoch
Bradley S. Schoch
CRChristopher P. Roche
Christopher P. Roche
Background: Despite the importance of the deltoid to shoulder biomechanics, very few studies have quantified the three-dimensional shape, size, or quality of the deltoid muscle, and no studies have correlated these measurements to clinical outcomes after anatomic (aTSA) and/or reverse (rTSA) total shoulder arthroplasty in any statistically/scientifically relevant manner. Methods: Preoperative computer tomography (CT) images from 1057 patients (585 female, 469 male; 799 primary rTSA and 258 primary aTSA) of a single platform shoulder arthroplasty prosthesis (Equinoxe; Exactech, Inc., Gainesville, FL) were analyzed in this study. A machine learning (ML) framework was used to segment the deltoid muscle for 1057 patients and quantify 15 different muscle characteristics, including volumetric (size, shape, etc.) and intensity-based Hounsfield (HU) measurements. These deltoid measurements were correlated to postoperative clinical outcomes and utilized as inputs to train/test ML algorithms used to predict postoperative outcomes at multiple postoperative timepoints (1 year, 2–3 years, and 3–5 years) for aTSA and rTSA. Results: Numerous deltoid muscle measurements were demonstrated to significantly vary with age, gender, prosthesis type, and CT image kernel; notably, normalized deltoid volume and deltoid fatty infiltration were demonstrated to be relevant to preoperative and postoperative clinical outcomes after aTSA and rTSA. Incorporating deltoid image data into the ML models improved clinical outcome prediction accuracy relative to ML algorithms without image data, particularly for the prediction of abduction and forward elevation after aTSA and rTSA. Analyzing ML feature importance facilitated rank-ordering of the deltoid image measurements relevant to aTSA and rTSA clinical outcomes. Specifically, we identified that deltoid shape flatness, normalized deltoid volume, deltoid voxel skewness, and deltoid shape sphericity were the most predictive image-based features used to predict clinical outcomes after aTSA and rTSA. Many of these deltoid measurements were found to be more predictive of aTSA and rTSA postoperative outcomes than patient demographic data, comorbidity data, and diagnosis data. Conclusions: While future work is required to further refine the ML models, which include additional shoulder muscles, like the rotator cuff, our results show promise that the developed ML framework can be used to evolve traditional CT-based preoperative planning software into an evidence-based ML clinical decision support tool.

12 September 2023 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
CAChristine Allen
Christine Allen
VKVikas Kumar
Vikas Kumar
JEJosie Elwell
Josie Elwell
SOSteven Overman
Steven Overman
BSBradley S. Schoch
Bradley S. Schoch
CRChristopher P. Roche
Christopher P. Roche

5 July 2025 in JSES International
Verified
Journal Article
Open access
HRHamidreza Rajabzadeh-Oghaz
Hamidreza Rajabzadeh-Oghaz
JEJosie Elwell
Josie Elwell
BSBradley Schoch
Bradley Schoch
WAWilliam Reuben Aibinder
William Reuben Aibinder
BGBruno Borralho Gobbato
Bruno Borralho Gobbato
CRChristopher P. Roche
Christopher P. Roche
The goal of this study is to analyze a registry of preoperative computed tomography (CT) images of anatomic total shoulder arthroplasty (aTSA) and reverse total shoulder arthroplasty (rTSA) patients, quantify the radiomics of the deltoid muscle and scapular bone, and identify the radiomic features that are most predictive of pain, motion, and function before and after aTSA/rTSA. Preoperative CT images and clinical data from 4,009 primary shoulder arthroplasty patients were retrospectively analyzed. Next, three-dimensional masks of the deltoid (n = 2,597) and scapula (n = 3,358) were auto-segmented from CT images, and radiomic features were extracted using Py-Radiomics. These radiomics features were then used to train machine-learning regression models to predict pain, motion, and function before and after aTSA/rTSA. Finally, a clustering analysis was performed using the most predictive radiomic features to identify unique deltoid and scapula morphological groups/classes relevant to clinical outcomes before and after aTSA/rTSA. Incorporating radiomic features into the machine-learning models improved the accuracy of 70.5% of deltoid model outcome predictions and 67.3% of scapular model outcome predictions. Analysis of feature importance data demonstrated that the most predictive radiomic features were numerical representations of deltoid and scapula shape and size. Notably, most shape-based radiomic features were more predictive of aTSA/rTSA outcomes than any patient demographic data (except age), comorbidity data, implant data, or diagnosis data. Finally, a radiomic-based clustering analysis identified several deltoid muscle and scapula bone morphologies associated with differences in clinical outcomes before and after aTSA/rTSA. This analysis of >4,000 preoperative CT scans identified numerous radiomic features of the deltoid and scapula that were highly predictive of pain, motion, and function before and after aTSA/rTSA. These most predictive radiomic features were aggregated into unique morphological clusters of deltoids and scapula that were associated with differences in clinical outcomes before and after aTSA/rTSA. Shape-based radiomic features were more predictive than first-order and second-order radiomic features, suggesting that these more interpretable measurements are more clinically relevant and could be more readily incorporated into future radiomic-based clinical decision support tools. Future work is required to further validate these radiomic findings and refine the proposed clustering analysis.

14 July 2025 in Algorithms
Verified
Journal Article
Open access
PDF file
HRHamidreza Rajabzadeh-Oghaz
Hamidreza Rajabzadeh-Oghaz
JEJosie Elwell
Josie Elwell
BSBradley S. Schoch
Bradley S. Schoch
WAWilliam Reuben Aibinder
William Reuben Aibinder
BGBruno Borralho Gobbato
Bruno Borralho Gobbato
CRChristopher P. Roche
Christopher P. Roche
Introduction: We developed a computed tomography (CT)-based tool designed for automated segmentation of deltoid muscles, enabling quantification of radiomic features and muscle fatty infiltration. Prior to use in a clinical setting, this machine learning (ML)-based segmentation algorithm requires rigorous validation. The aim of this study is to conduct shoulder expert validation of a novel deltoid ML auto-segmentation and quantification tool. Materials and Methods: A SwinUnetR-based ML model trained on labeled CT scans is validated by three expert shoulder surgeons for 32 unique patients. The validation evaluates the quality of the auto-segmented deltoid images. Specifically, each of the three surgeons reviewed the auto-segmented masks relative to CT images, rated masks for clinical acceptance, and performed a correction on the ML-generated deltoid mask if the ML mask did not completely contain the full deltoid muscle, or if the ML mask included any tissue other than the deltoid. Non-inferiority of the ML model was assessed by comparing ML-generated to surgeon-corrected deltoid masks versus the inter-surgeon variation in metrics, such as volume and fatty infiltration. Results: The results of our expert shoulder surgeon validation demonstrates that 97% of ML-generated deltoid masks were clinically acceptable. Only two of the ML-generated deltoid masks required major corrections and only one was deemed clinically unacceptable. These corrections had little impact on the deltoid measurements, as the median error in the volume and fatty infiltration measurements was <1% between the ML-generated deltoid masks and the surgeon-corrected deltoid masks. The non-inferiority analysis demonstrates no significant difference between the ML-generated to surgeon-corrected masks relative to inter-surgeon variations. Conclusions: Shoulder expert validation of this CT image analysis tool demonstrates clinically acceptable performance for deltoid auto-segmentation, with no significant differences observed between deltoid image-based measurements derived from the ML generated masks and those corrected by surgeons. These findings suggest that this CT image analysis tool has potential to reliably quantify deltoid muscle size, shape, and quality. Incorporating these CT image-based measurements into the pre-operative planning process may facilitate more personalized treatment decision making, and help orthopedic surgeons make more evidence-based clinical decisions.

16 October 2026 in JSES International
Verified
Journal Article
Open access
GSGregory W. Spangenberg
Gregory W. Spangenberg
HRHamidreza Rajabzadeh-Oghaz
Hamidreza Rajabzadeh-Oghaz
JEJosie Elwell
Josie Elwell
VKVikas Kumar
Vikas Kumar
CRChristopher P. Roche
Christopher P. Roche
GLG. Daniel G. Langohr
G. Daniel G. Langohr