Abdelgadir Mohamed Mahmoud

Dr. Abdelgadir Mohamed Mahmoud

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 August 2024 in Energies
Verified
Journal Article
Open access
PDF file
MHMahmood Abduljabbar Hammad
Mahmood Abduljabbar Hammad
AMAbdelgadir Mohamed Mahmoud
Abdelgadir Mohamed Mahmoud
AAAhmed Mohammed Abdelrhman
Ahmed Mohammed Abdelrhman
SSShamsul Sarip
Shamsul Sarip
Blade pitch angle regulation is an effective approach to enhance the performance of H-type Darrieus Vertical Axis Wind Turbines (VAWTs). Improving the blade interaction with the wind for this type of rotor is a challenging task, especially in unsteady wind conditions. This paper presents a novel hybrid approach that integrates fixed and variable blade pitch angle regulation techniques, aiming to enhance the wind turbine efficiency across various operational stages and wind speeds. The proposed blade pitch angle regulation method targets a less complicated, mechanically feasible, and cost-effective pitching technique. This study uses the Double Multiple Streamtube (DMST) model to analyze the aerodynamic performance and calculate the power output generated at different pitch angles. MATLAB Simulink was utilized to implement the DMST model, and experimental validation was conducted to confirm the results. The findings indicate that the blade pitch angle regulation has significantly enhanced the self-starting ability of H-type Darrieus VAWT by 80%. Additionally, the maximum rotational speed and power coefficient are achieved at a zero pitch angle. Furthermore, regulating the blade pitch angle allows for the effective control of excessive rotational speeds during high wind conditions.

1 February 2023 in Fire
Verified
Journal Article
Open access
PDF file
MOMusab Omar
Musab Omar
AMAbdelgadir Mohamed Mahmoud
Abdelgadir Mohamed Mahmoud
SASa’ardin Bin Abdul Aziz
Sa’ardin Bin Abdul Aziz
The purpose of this paper was to develop a fire index system for measuring the compliance of high-rise residential buildings with fire requirements in the Emirate of Sharjah, and also to develop an index system for measuring the fire response efficiency, which is linked the two indexes, and the higher the compliance rate, the greater chance of a successful response. The two systems depend on the automation of the firefighting system management processes using the techniques of the fourth industrial revolution, and they were developed based on consultation with subject matter experts in the field and used multiple methods, such as the analytic hierarchy process, failure mode effect, criticality analysis, and Delphi techniques. The main criteria of the indexes were identified as the fire risk assessment, fire suppression system, fire accident management, fire alarm system, fire extinguisher, employees, residents, service rooms, lifts, gas connections, waste, housekeeping, and evacuation facilities. Each main criterium was detailed in the sub-criteria and weighted to achieve the index for each sub-criteria based on the fire legislation in UAE, the fire response index (developed based on the high-rise building fire index), the category of the building in terms of floor numbers, and the distance between building and the fire station. The two index systems can contribute to improving emergency preparedness in high-rise residential buildings in the Emirate of Sharjah and are also considered as measurement indexes for compliance with fire requirements in the Emirate of Sharjah.

15 February 2023 in Fire
Verified
Journal Article
Open access
PDF file
MOMusab Omar
Musab Omar
AMAbdelgadir Mohamed Mahmoud
Abdelgadir Mohamed Mahmoud
SASa’ardin Bin Abdul Aziz
Sa’ardin Bin Abdul Aziz
The purpose of this paper is to identify the critical factors affecting fire accidents in high-rise residential buildings in the Emirate of Sharjah in order to find solutions that contribute to reducing injuries and deaths from fire accidents. A large urban expansion of the Emirate of Sharjah has taken place in the form of high-rise buildings, and the Emirate is now third in the UAE in terms of the number of high-rise buildings and is home to 19% of the population. As a consequence, an increase in the rate of fire accidents has also been observed. As such, there is a need to conduct research on enhancing fire safety in high-rise buildings by conducting a literature review, in which nineteen factors affecting fire globally were identified. Because the fire characteristic is unique in every country, to identify the nature of fire in the Emirate of Sharjah, we consulted sixteen subject matter experts in the field of fire in the Emirate of Sharjah to identify the factors applicable to the Emirate. We used the failure mode, effect, and criticality analysis methodology to accomplish this goal. The outcome of the consultations resulted in the three main factor categories, which are management factors, human factors, and technical factors, and the critical factors affecting the high-rise buildings in the Emirate of Sharjah were identified, which are: fire regulations, fire enforcement regulations, accident investigation, rescue speed, human behavior, lack of proper maintenance, fire training, building design, fire knowledge, combustible materials, fire culture of society, and urbanization. Using the Analytical Hierarchy Process (AHP) tools implemented to measure the effect level of the sub-critical fire factors, 45 effects were identified, and the most common effects were: the building is fully covered by cladding, the effect of stopping activities in HRBs that are non-compliant with fire regulations, the residents practice activities related to fire knowledge, fire regulations efficiency, the training of new employees by their employers, and the residents have fire-related knowledge.

22 March 2024 in Buildings
Verified
Journal Article
Open access
PDF file
PMPayal Ashish Modi
Payal Ashish Modi
AMAbdelgadir Mohamed Mahmoud
Abdelgadir Mohamed Mahmoud
YAYousif Abdalla Abakr
Yousif Abdalla Abakr
In regions with hot climates such as Bahrain, the utilization of air conditioning is indispensable in both public and private buildings to attain thermally comfortable indoor environments. External walls, constructed with building blocks, play a crucial role in the heat penetration into the building system. Despite extensive research on the cavity designs of building blocks, there has been a lack of comparison between individual block systems and integrated multi-block systems, considering both thermal and mechanical performance criteria simultaneously. Therefore, it is imperative to gather and review information on key parameters influencing the thermomechanical performance of building blocks, along with investigating techniques used to evaluate these parameters according to international standards. This review primarily focuses on these aspects. Additionally, it presents the historical evolution of housing types and the standard procedures followed by the Bahraini Government and block manufacturing companies in alignment with energy efficiency policies in Bahrain. Ultimately, this review aims to inspire researchers to explore other viable and innovative designs for enhancing the thermal insulation of building walls. By doing so, this work will contribute to Bahrain’s 2030 goals of fostering sustainability and mitigating environmental impact at a local level, while also aligning with the United Nations’ Sustainable Development Goals (SDGs) for 2030, specifically SDG 11, which aims to “make cities and human settlements sustainable”.

2 July 2024 in Buildings
Verified
Journal Article
Open access
PDF file
Payal Ashish ModiPayal Ashish Modi
Payal Ashish Modi
AMAbdelgadir Mohamed Mahmoud
Abdelgadir Mohamed Mahmoud
YAYousif Abdalla Abakr
Yousif Abdalla Abakr
AAAbdulla Ebrahim Abdulqader
Abdulla Ebrahim Abdulqader
The increase in energy consumption in Bahrain is a significant issue. Insulation blocks are crucial for reducing heat transfer from outside to inside buildings. However, there’s limited research on the thermal performance of Bahrain’s insulation building blocks. No research to date has been conducted in Bahrain to study the effect of plaster and insulation inserts on the R-value of the blocks. This study examines and optimizes the thermal resistance (R-value) of an ‘Integrated Masonry System International, Ltd. (IMSI)’ block, chosen due to its common use in Bahrain’s commercial and residential construction. The study involves experimental analysis using a hot box setup and numerical analysis through the finite element method (FEM), along with assessing the impact of insulation inserts in the block’s cavities. R-values are calculated and validated for accuracy. The R-value discrepancy between numerical and experimental findings is 2.411%, and between numerical and manufacturer’s data is 5.743%. It is also observed that a 25 mm external plaster, as required by Bahrain’s government (EWA), enhances the R-value by 79.34%. Furthermore, optimizing the IMSI block’s height increased the R-value by 10.67%.

28 December 2022 in Preprints.org
Verified
Preprint
Open access
PDF file
MOMusab Omar
Musab Omar
AMAbdelgadir Mohamed Mahmoud
Abdelgadir Mohamed Mahmoud
SASa'Ardin Abdul Aziz
Sa'Ardin Abdul Aziz
The purpose of this paper is to develop an index system for measuring the compliance of high-rise residential buildings with fire requirements and also to develop an index system for measuring the fire response efficiency, which is linked to the index of compliance with fire requirements. The higher the compliance rate, the greater the chance of a successful response. The two systems de-pend on the automation of the firefighting system management processes using the techniques of the fourth industrial revolution and developed based on the consultation of subject matter experts in the field. The main elements of the indexes were identified, which were based mainly on several variables, including the fire administrative system, the firefighting system, the residents, the loca-tion of the high-rise residential buildings from the fire extinguishing station, and the height of the high-rise residential building. The two systems can contribute to improving emergency prepared-ness in high-rise residential buildings in the Emirate of Sharjah and are also considered as a measurement index for compliance with fire requirements in the Emirate of Sharjah.