Simpy Sanyal

Dr. Simpy Sanyal


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2024 in Coatings
Verified
Journal Article
Open access
PDF file
SSSimpy Sanyal
Simpy Sanyal
SPSeonJu Park
SeonJu Park
RCRamachandran Chelliah
Ramachandran Chelliah
SYSu-Jung Yeon
Su-Jung Yeon
KBKALIYAN BARATHIKANNAN
KALIYAN BARATHIKANNAN
Deog-Hwan OhDeog-Hwan Oh
Deog-Hwan Oh
Smart self-healing coatings offer a revolutionary approach to mitigating metal corrosion, a problem with significant economic and environmental impacts. Divided into intrinsic and extrinsic types, these coatings autonomously rectify the damage. Intrinsic variants utilize reversible bonds to achieve ongoing repair, while extrinsic ones incorporate micro/nanocontainers that activate upon environmental triggers to mend micro-cracks, their efficacy dictated by the encapsulated healing agents’ volume. This review dissects the rapidly evolving sector of stimuli-responsive self-healing coatings, emphasizing the progress in micro/nano container technology. It discusses the synthesis and encapsulation processes of different micro/nanocontainers and charts the transition from single to multistimulus-responsive systems, which enhances the coatings’ sensitivity and functionality. The addition of multifunctional traits such as self-reporting and anti-microbial actions further broadens their industrial applicability. The review provides a succinct overview of the field’s current state and future potential, envisioning a paradigm shift in corrosion protection through advanced smart coatings.

19 January 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SSSimpy Sanyal
Simpy Sanyal
TKTaeyong Kim
Taeyong Kim
JYJunsin Yi
Junsin Yi
JKJa-Bin Koo
Ja-Bin Koo
JSJu-Am Son
Ju-Am Son
ICIn-Hyuk Choi
In-Hyuk Choi
The aging of porcelain insulators is responsible for the failure of power utilities. Porcelain insulators from different places in South Korea, possessing various aging times and years of installation, have been investigated to carry out lifetime statistics. These samples have a mass of 36,000 lbs and are operated at 154 kV. X-ray fluorescence (XRF) and scanning electron microscopy (SEM) were performed on the porcelain bodies of the samples collected. XRF and SEM revealed trends in the weight percentage of SiO2, Al2O3, and Fe2O3 in the porcelain bodies of the collected samples. The SiO2 and Fe2O3 weight percentage reduced to 8.93% and 73.17%, respectively, in sample C compared to A. However, the Al2O3 weight percentage increased to 16.23% in sample C compared to sample A. This change in weight percentage of SiO2, Fe2O3, and Al2O3 contributed toward enhancing the mechanical and electrical properties of the insulators. Mechanical load tests with electrical voltage (M&E), thermal and mechanical load tests (T&M), and hardness tests (HRB) were performed to evaluate these characteristics. Experiments revealed an increase of 90.9% in the inequality factor (K) in sample C compared to A. The impact of constituents of porcelain on the lifetime expectancy of a porcelain insulator was reported by implementing statistical strategies, such as the Weibull distribution.

6 January 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TKTaeyong Kim
Taeyong Kim
YLYoun-Jung Lee
Youn-Jung Lee
SSSimpy Sanyal
Simpy Sanyal
JWJung-Wook Woo
Jung-Wook Woo
ICIn-Hyuk Choi
In-Hyuk Choi
JYJunsin Yi
Junsin Yi
Porcelain insulators should be exchanged periodically, but their lifetime is not clearly defined. One factor that affects service life is corrosion occurring at the pin and cap—each of which is made of iron with a zinc coating. A number of porcelain insulators used for different lengths of time in different locations are gathered, and the corrosion mechanisms of the cap and pin are investigated. The corrosion mechanism of the cap is mainly galvanic corrosion while that of the pin is primarily electrolytic and crevice corrosion as well as galvanic corrosion. Although time is an important factor in corrosion, it is found that corrosion is more influenced by geographical factors. Since the amount of acid rain and sea salt—each of which causes rapid rusting—is dependent on geographical factors, the location of where porcelain insulators are installed should be considered when predicting their lifetime. Theoretically, if there is only galvanic corrosion occurring, the expected lifetime is 56 years in an industrial area when the zinc coating has a thickness of 75 µm. Previous articles dealing with aging have predicted the maximum lifetime of porcelain insulators used in Korea to be approximately 30 years. To prolong the lifetime of porcelain insulators, further study is required in which the use of zinc alternatives, or waterproof coatings (in addition to the zinc coating), could be examined.

20 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
SSSimpy Sanyal
Simpy Sanyal
TKTaeyong Kim
Taeyong Kim
CSChang-Sung Seok
Chang-Sung Seok
JYJunsin Yi
Junsin Yi
JKJa-Bin Koo
Ja-Bin Koo
ICIn-Hyuk Choi
In-Hyuk Choi
Insulators comprise only 5% of the capital cost of transmission lines; they are accountable for 70% of line interruptions and 50% of maintenance costs of transmission lines. Major transmission lines situated in different parts of the world were mostly all constructed 30 years ago. These lines have either completed or are approaching the active life at 30 years. It is not possible to replace all insulators at a time in any utility. From a standpoint of consistency, it is quite important to locate insulators that require replacement prior to the occurrence of failure. Recalling these issues, a replacement strategy was modeled on insulator samples, operated at 154 kV, mechanical and electrical rating (M+E) 25,000 lbs and within the 10–50 years (Y) age group, collected in bulk for laboratory evaluation, based on the probability of mechanical failure (P(F)) of insulators. For conducting these studies, tensile load test such as combined electrical and mechanical failing load test was performed on selected 30 new and aged porcelain insulator samples from bulk to access recent condition. It was observed that insulators under service for 50 years manifested a decrease of 89.3% in quality factor (K), as compared to insulators within 10 years of service. A micro-structural study was carried out by using an optical microscope (OM) and a scanning electron microscope (SEM) for the further confirmation of previous evaluations. P(F) was derived by implementing Weibull distribution on the experimental observations. It was observed that insulators with an age of 50 years depicted a 2.7% increase in P(F), as compared to insulators with an age of 10 years. This article discussed a strategy for accessing the recent condition of new, aged bulk samples and the criteria of the replacement of the insulator string based on P(F).

23 December 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TKTaeyong Kim
Taeyong Kim
SSSimpy Sanyal
Simpy Sanyal
JKJa-Bin Koo
Ja-Bin Koo
JSJu-Am Son
Ju-Am Son
ICIn-Hyuk Choi
In-Hyuk Choi
JYJunsin Yi
Junsin Yi
The deterioration of the cement that bonds the cap, pin, and porcelain shell of the porcelain insulators can be observed by three-dimensional computed tomography (3D-CT), a non-destructive test. When porcelain insulators are used for a long duration, the size of the pores existing in the cement increase as the cement expands due to the alkali-silica reaction (ASR). It is possible to visually confirm the corrosion of caps and pins. The degree of corrosion is divided into four noticeable stages (I–IV), and deterioration of cement includes one of the four stages of corrosion. The standard time of replacement of insulator vs. continued use is presented. As a result of X-ray diffraction (XRD) analysis, Fe is oxidized to Fe2O3 at 36, 43, 54, and 70 degrees. The corrosion in cement is caused by factors including the value of pH, oxygen content, and temperature. For the caps and pins, although a zinc coating is applied to prevent the corrosion of iron, corrosion of zinc is caused by substances present in the external environment. When the zinc coating begins to corrode, the corrosion of the Fe component of the cap and pin accelerates, causing mechanical/electrical problems.

13 December 2019 in Materials
Verified
Journal Article
Open access
PDF file
TKTaeyong Kim
Taeyong Kim
SSSimpy Sanyal
Simpy Sanyal
JKJa-Bin Koo
Ja-Bin Koo
JSJu-Am Son
Ju-Am Son
ICIn-Hyuk Choi
In-Hyuk Choi
JYJunsin Yi
Junsin Yi
Suspension type porcelain insulators used in overhead transmission lines comprise metal, ceramic, and cement. The deterioration of cement can lead to mechanical separation. For the degradation analysis, varied sizes of pores ranging from a few µm (capillary pores) to tens to hundreds of mm (detectable by naked eyes) were considered. Cracks that were hard to view with naked eyes were identified by staining with a fuchsine solution. The hydrogen ion concentration and pH value indicate the extent to which the cement is deteriorated. The longer the cement is used, the lower its pH value. High mechanical strength is considered an important advantage of porcelain insulators, and it may decline, if the cement is used for a longer period of time. Water ingress may also occur, resulting in expansion, due to the rehydration of the cement. The process and mechanism of expansion of cement, due to infiltration of water were described. As a method of analysis, a universal indicator was employed to evaluate the pH changes in cement. It was observed that the pH value was 12–13 for new products. However, for products that were used for 52 years, the pH value was under 7, which indicated an acidic tendency, due to deterioration.