Min-Ku Chon

Prof. Dr. Min-Ku Chon

Pusan National University Yangsan Hospital, Yangsan, Gyeongnam, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Korean Circulation Journal
Verified
Journal Article
Open access
PDF file
SLSoo Yong Lee
Soo Yong Lee
TLTae Wook Lee
Tae Wook Lee
GPGyutae Park
Gyutae Park
JKJae Ho Kim
Jae Ho Kim
HLHyun-Chae Lee
Hyun-Chae Lee
JHJin Hur
Jin Hur
Korean Circulation Journal 대한심장학회지 순환기 Lee SY, et al. Korean Circ J. 2020 Oct;51:e15. https://doi.org/10.4070/kcj.2020.0303

1 January 2023 in International Journal of Heart Failure
Verified
Journal Article
Open access
PDF file
JLJi Hoon Lim
Ji Hoon Lim
SLSoo Yong Lee
Soo Yong Lee
MJMin Ho Ju
Min Ho Ju
SKSeok Hyun Kim
Seok Hyun Kim
JCJin Hee Choi
Jin Hee Choi
HJHyunggon Je
Hyunggon Je
Lim JH, et al. Int J Heart Fail. 2023 Apr;5:e11. https://doi.org/10.36628/ijhf.2023.0013

21 November 2019 in Clinical Anatomy
Verified
Journal Article
Closed access
PDF file
SLSoo Yong Lee
Soo Yong Lee
SLSang Hyun Lee
Sang Hyun Lee
SJSoon Myung Jung
Soon Myung Jung
JCJin Hee Choi
Jin Hee Choi
MCMin-Ku Chon
Min-Ku Chon
JPJin Sup Park
Jin Sup Park

2 August 2021 in Coatings
Verified
Journal Article
Open access
PDF file
MCMin-Ku Chon
Min-Ku Chon
DSDong-Hoon Shin
Dong-Hoon Shin
SJSu-Jin Jung
Su-Jin Jung
HPHyeon-Jun Park
Hyeon-Jun Park
JKJune-Hong Kim
June-Hong Kim
Spacers, such as FORMA (Edwards Lifescience) or Mitraspacer, are used to treat mitral regurgitation or tricuspid regurgitations. However, they require external therapeutic liquid filler injection into the spacer device. This should be leak-tight over the time of implantation, which is a major limitation in device design. Here, we propose a self-expandable spacer with a nitinol inner mesh and expanded poly (tetrafluoroethylene) (ePTFE) coating that also functions as a spacer. We designed nitinol 3D mesh templates, coated with a commercially available low and high durometer ePTFE membrane. Finally, we implanted the spacer into a swine pulmonary artery and right atrium (superior vena cava) as an intervention technique. Twenty-four swine were used, except in two cases suspected of procedural infection. The results were analyzed in the remaining 22 cases and all devices were easily delivered and had good function in self-expansion and implantation. After eight weeks, all individuals were examined for gross and pathological analysis to determine the biological safety of the device. There was no evidence of damage or other abnormalities and increased postoperative endothelialization outside of ePTFE coatings. In conclusion, this study suggests using a self-expandable spacer to complement the medical limitations of the existing filling-type spacer devices.

9 April 2024 in Coronary Artery Disease
Verified
Journal Article
Closed access
MKMin Gyu Kang
Min Gyu Kang
JAJong-Hwa Ahn
Jong-Hwa Ahn
JHJin-Yong Hwang
Jin-Yong Hwang
SHSeok-Jae Hwang
Seok-Jae Hwang
JKJin-Sin Koh
Jin-Sin Koh
MCMin-Ku Chon
Min-Ku Chon
Background: Cilostazol has a vasodilatory function that may be beneficial for patients with vasospastic angina (VSA). We conducted a randomized, open-label, controlled trial to compare the efficacy and safety of long-acting cilostazol and isosorbide mononitrate (ISMN) for VSA. Methods: The study included patients with confirmed VSA between September 2019 and May 2021. Participants were randomly assigned to receive long-acting cilostazol (test group, 200 mg once daily) or conventional ISMN therapy (control group, 20 mg twice daily) for 4 weeks. The clinical efficacy and safety were evaluated using weekly questionnaires. Results: Forty patients were enrolled in the study (long-acting cilostazol, n = 20; ISMN, n = 20). Baseline characteristics were balanced between the two groups. Long acting cilostazol showed better angina symptom control within the first week compared to ISMN [reduction of pain intensity score, 6.0 (4.0–8.0) vs. 4.0 (1.0–5.0), P = 0.005; frequency of angina symptom, 0 (0–2.0) vs. 2.0 (0–3.0), P = 0.027, respectively]. The rate of neurological adverse reactions was lower in the cilostazol group than in the ISMN group (headache or dizziness, 40 vs. 85%, P = 0.009; headache, 30 vs. 70%, P = 0.027). Conclusion: Long-acting cilostazol provided comparable control of angina and fewer adverse neurologic reactions within 4 weeks compared to ISMN. Long-acting cilostazol provides more intensive control of angina within 1 week, suggesting that it may be an initial choice for the treatment of VSA.

28 August 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
MCMin-Ku Chon
Min-Ku Chon
SJSu-Jin Jung
Su-Jin Jung
JSJae-Young Seo
Jae-Young Seo
DSDong-Hoon Shin
Dong-Hoon Shin
JPJunhui Park
Junhui Park
JKJune-Hong Kim
June-Hong Kim
The Pivot Mandu is an innovative device featuring a leak-tight adjustable 3D balloon spacer, incorporating inner mesh support, an outer e-PTFE layer, and a compliant balloon in the middle layer with a specialized detachable system. To assess its feasibility, proof of concept was rigorously evaluated through bench testing and survival porcine animal experiments. The results demonstrated successful remote inflation of the balloon system, with the balloon spacer exhibiting sustained patent and functional integrity over an extended observation period of up to 6 months. A noteworthy feature of the newly designed 3D balloon spacer is its capability for easy size adjustment during procedures, enhancing its adaptability and practicality in clinical settings. This three-layered 3D balloon spacer, with its established long-term patency, exhibits highly encouraging outcomes that hold promise in overcoming the current limitations of spacer devices for heart valve diseases. Given the compelling results from preclinical investigations, the translation of the Pivot Mandu into human trials is strongly warranted.