Yi Tao

Dr. Yi Tao


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Construction and Building Materials
Verified
Journal Article
Closed access
XZXiao-Long Zheng
Xiao-Long Zheng
YTYi Tao
Yi Tao
QSQingxuan Shi
Qingxuan Shi
JCJian-Fei Chen
Jian-Fei Chen

1 January 2018 in Advances in Civil Engineering
Verified
Journal Article
Open access
JGJin-Ben Gu
Jin-Ben Gu
YTYi Tao
Yi Tao
RXRen Xin
Ren Xin
ZYZ. Yang
Z. Yang
QSQing-Xuan Shi
Qing-Xuan Shi
FRP composites have been used for strengthening RC and masonry structures for decades. However, the researches on repairing multistorey masonry structures using FRP grids were relative less. In the present paper, an experimental study on the seismic performance of multistorey masonry structure with openings repaired with CFRP grid is introduced. Specifically, a 1/3‐scale three‐floor masonry wall with window openings was tested under quasistatic action to simulate the seismic damages. The damaged masonry wall was then repaired by externally bonding CFRP grids to the areas where the cracks intensively occurred. The repaired masonry wall was retested under the same loading to investigate the seismic resistance and assess the recovery attributed from the CFRP grid repairing. The findings of this study showed that CFRP grid repairing could effectively postpone or even prevent the occurrence and development of cracking. The seismic resistance of the masonry, including shear capacity, energy dissipation capacity, deformability, stiffness degradation, and ductility, was restored. The application of CFRP grid may shift the failure mechanism of the multistorey masonry wall. The recommendation of repair scheme for the similar structures was also proposed in accordance with the findings of the present work.

16 May 2024 in Advances in Structural Engineering
Verified
Journal Article
Closed access
DWDan Wang
Dan Wang
YTYi Tao
Yi Tao
JGJinben Gu
Jinben Gu
ZCZhiheng Chen
Zhiheng Chen
QSQingxuan Shi
Qingxuan Shi
A novel composite column was introduced by integrating a concrete-filled steel tube column encasing a Fiber Reinforced Polymer (FRP) confined ultra high performance concrete (UHPC) core. In this paper, the seismic performance of four SCF-UHPC composite column-to-steel beam connections using external diaphragm joints was experimentally investigated under the quasi-static test. All specimens failed due to the formation of plastic hinges at the beams and the tearing failure on the beam flanges at the plastic hinge zone. The local buckling at the column end and the panel zone was observed for the specimens receiving the higher axial compression ratio. The increase of FRP tube thickness is more effective in improving the ductility and energy dissipation capacity of the joints than increasing the UHPC core diameter. On the contrary, increasing the UHPC core diameter led to better resistance to the shear deformation of the panel zone. The proportion of shear deformation to the total deformation of the panel zone and the strain distributions were investigated to determine the effect of each component. The composite column in the panel zone mainly carried the compression-bending effort, and the external diaphragm mainly took the shear effort. All joints were eventually classified as semi-rigid type joints, according to the initial rotational stiffness.

25 November 2025 in Buildings
Verified
Journal Article
Open access
PDF file
GGGu,  Jin-Ben Gu
Gu,  Jin-Ben Gu
ZXZe-Yu Xie
Ze-Yu Xie
FYFan Yang
Fan Yang
YTYi Tao
Yi Tao
Based on the design concept of double-skin composite columns, this study proposes an enhanced configuration in which the inner steel tube is reinforced with fiber-reinforced polymer (FRP) stirrup-confined ultra-high-performance concrete (UHPC), leading to the development of FRP stirrup-confined UHPC–steel tube (FSCUS) hollow composite columns. Twelve glass FRP stirrup-confined UHPC–steel tube (GFSCUS) hollow composite column specimens were tested under axial compression. Analysis of load–displacement curves, and of load–strain curves of individual components, was performed. The effects of various parameters, including thickness and outer diameter of the steel tube, configuration and spacing of the GFRP stirrup, and steel fiber content of the UHPC, on the compressive behavior of the GFSCUS hollow composite columns were systematically investigated. The test results indicate that the influence of the thickness and outer diameter of the steel tube on the axial compression behavior is primarily governed by the effectiveness of the composite action between the steel tube and the confined concrete under axial compression load. The spacing and configuration of the FRP stirrup, conversely, determine the efficacy of the confinement provided to the concrete. The incorporation of steel fibers enhances both the peak load and the ductility due to their bridging effect. However, an excessive fiber content can restrict the lateral expansion of the concrete, thereby diminish the confining effect of the hoops and leading to a reduction in load-carrying capacity.

5 July 2025 in Buildings
Verified
Journal Article
Open access
PDF file
GGGu,  Jin-Ben Gu
Gu,  Jin-Ben Gu
YCYu-Han Chen
Yu-Han Chen
YTYi Tao
Yi Tao
JWJun-Yan Wang
Jun-Yan Wang
SZShao-Xiong Zhang
Shao-Xiong Zhang
This study investigates how different longitudinal steel rebars influence the flexural performance and cracking mechanisms of reinforced ultra-high-performance concrete (UHPC) beams, combining axial tensile tests using acoustic emission monitoring with standard four-point bending tests. A series of experimental assessments on the flexural behavior of UHPC beams reinforced with various types of longitudinal reinforcement was conducted. The types of longitudinal reinforcement mainly encompassed HRB 400, HRB 600, and NPR steel rebars. The test results revealed that the UHPC beams reinforced with the three types of longitudinal steel rebar exhibited distinctly different failure modes. Compared to the single dominant crack failure typical of UHPC beams reinforced with HRB 400 steel rebars, the beams using HRB 600 rebars exhibited a tendency under balanced failure conditions to develop fewer main cracks (typically two or three). Conversely, the UHPC beams incorporating NPR steel rebars exhibited significantly more cracking within the pure bending zone, characterized by six to eight uniformly distributed main cracks. Meanwhile, the HRB 600 and NPR steel rebars effectively upgraded the flexural load-bearing capacity and deformation ability compared to the HRB 400 steel rebars. By integrating the findings from the direct tensile tests on reinforced UHPC, aided by acoustic emission source location, this research specifically highlights the damage mechanisms associated with each rebar type.

17 April 2025 in Advances in Structural Engineering
Verified
Journal Article
Closed access
PWPeng Wang
Peng Wang
XYXue-Hui You
Xue-Hui You
QSQing-Xuan Shi
Qing-Xuan Shi
YTYi Tao
Yi Tao
CRChong Rong
Chong Rong
JHJie Huang
Jie Huang
This study investigated the bonding performance of the interface treated by ribs between Ultra-High Performance Concrete (UHPC) and Normal Concrete (NC) through double shear tests and finite element analysis. Besides, according to existing research results, the calculation methods for the shear capacity of the interface between UHPC and NC were discussed. The results show that specimens with a rib width of less than 20 mm were predominantly susceptible to rib shear failure, whereas those with a rib width exceeding 20 mm primarily exhibited NC fractures failure. The impact of rib height and rib spacing on the interface failure mode was complex and should be assessed based on the rib width. When the rib width was less than 20 mm, with an increase in rib spacing, the shear bearing capacity of the interface remained nearly constant. Nevertheless, when the rib width was 30 mm, the bearing capacity gradually decreased with an increase in rib spacing. Additionally, the bearing capacity initially increased and then decreased with an increase in rib height for specimens with a rib width exceeding 10 mm. The current calculation methods neglected the bearing capacity provided by the ribs, resulting in significant discrepancies between calculated results and experimental values.